4 resultados para Volenti non fit injuria
em CiencIPCA - Instituto Politécnico do Cávado e do Ave, Portugal
Resumo:
Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor
Resumo:
Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor.
Resumo:
Purpose/objectives: This paper seeks to investigate whether performance management (PM) framework adopted in Portuguese local government (PLG) fit the Otley’s PM framework (1999). In particularly, the research questions are (1) whether PM framework adopted in PLG (SIADAP) fit the Otley´s framework, and (2) how local politicians (aldermen) see the operation of performance management systems (PMS) in PLG (focusing on the goal-setting process and incentive and reward structures). Theoretical positioning/contributions: With this paper we intend to contribute to literature on how the Otley’s PM framework can guide empirical research about the operation of PMS. In particular, the paper contributes to understand the fit between PMS implemented in PLG and the Otley´s PM framework. The analysis of this fit can be a good contribution to understand if PMS are used in PLG as a management tool or as a strategic response to external pressures (based on interviews conducted to aldermen). We believe that the Otley’s PM framework, as well as the extended PM framework presented by Ferreira and Otley (2009), can provide a useful research tool to understand the operation of PMS in PLG. Research method: The first research question is the central issue in this paper and is analyzed based on the main reforms introduced by Portuguese government on PM of public organizations (like municipalities). On the other hand, interviews conducted on three larger Portuguese municipalities (Oporto, Braga, and Matosinhos) show how aldermen see the operation of PMS in PLG, highlighting the goals setting process with targets associated and the existing of incentive and reward structures linked with performance. Findings: Generally we find that formal and regulated PM frameworks in PLG fit the main issues of the Otley’s PM framework. However, regarding the aldermen perceptions about PMS in practice we find a gap between theory and practice, especially regarding difficulties associated with the lack of a culture of goals and targets setting and the lack of incentive and reward structures linked with performance.
Resumo:
Background: Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose: The aim of this study was to identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods: A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit.A total of 417 articles were identified; 32 were selected for review. Results: All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique, and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in nine; six studies tested vinyl polysiloxane and one study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intraoral optical devices were compared in four studies. Conclusions: The most accurate results were achieved with two configurations: (1) the optical intraoral system with powder and (2) the open technique with splinted squared transfer copings, using polyether as impression material.