3 resultados para Tibia fractures
em CiencIPCA - Instituto Politécnico do Cávado e do Ave, Portugal
Resumo:
In the last decade, population ageing has been registered as a global phenomenon. A relation exists between falling and ageing, since falling frequency increases significantly with age. In fact, one in three older adult falls annually. Although ageing is generically associated with decrease and degeneration of psychological and physical functions, it is still not common for the correct identification of risk factors to lead to a clinical prognosis of the elder being in risk of falling. Therefore, the goal of this review article is to identify, categorise and analyse typical ageing and fall factors mentioned in the literature as well as to quantify the number of times they were referenced. The research considered hundreds of publications, but analysis was then restricted to the 87 most pertinent articles written in English and published in journals or scientific magazines between 1995 and 2010. We concluded that falls among older adults can be characterised by the following: anatomic characteristics and physiological consequences of ageing; the pathologies that induce falls, which can be neurological, musculoskeletal, cardiovascular and other diseases; causes and risk factors of falls that can be behavioural, biological, environmental or socio-economic; type of physical consequences of falls, including fractures, bruises, injuries or other physical consequences; and strategies to prevent, mitigate or rehabilitate, which can be of a physical, environmental or behavioural nature.
Resumo:
In the last decade, population ageing has been registered as a global phenomenon. A relation exists between falling and ageing, since falling frequency increases significantly with age. In fact, one in three older adult falls annually. Although ageing is generically associated with decrease and degeneration of psychological and physical functions, it is still not common for the correct identification of risk factors to lead to a clinical prognosis of the elder being in risk of falling. Therefore, the goal of this review article is to identify, categorise and analyse typical ageing and fall factors mentioned in the literature as well as to quantify the number of times they were referenced. The research considered hundreds of publications, but analysis was then restricted to the 87 most pertinent articles written in English and published in journals or scientific magazines between 1995 and 2010. We concluded that falls among older adults can be characterised by the following: anatomic characteristics and physiological consequences of ageing; the pathologies that induce falls, which can be neurological, musculoskeletal, cardiovascular and other diseases; causes and risk factors of falls that can be behavioural, biological, environmental or socio-economic; type of physical consequences of falls, including fractures, bruises, injuries or other physical consequences; and strategies to prevent, mitigate or rehabilitate, which can be of a physical, environmental or behavioural nature.
Resumo:
The success of artificial prosthetic replacements depends on the fixation of the artificial prosthetic component after being implanted in the thighbone. The materials for fixation are subject to mechanical stresses, which originate permanent deformations, incipient cracks and even fatigue fractures. This work shows the possibility of monitoring the mechanical stress over time in prosthesis. In this way, highly sensitive silicon thin-film piezoresistive sensors were developed attached to prosthesis and their results compared with commercial strain gauge sensors. Mechanical stress-strain experiments were performed in compressive mode, during 10,000 cycles. Experimental data was acquired at mechanical vibration frequencies of 0.5 Hz, 1 Hz and 5 Hz, and sent to a computer by means of a wireless link. The results show that there is a decrease in sensitivity of the thin-film silicon piezoresistive sensors when they are attached to the prosthesis, but this decrease does not compromise its monitoring performance. The sensitivity, compared to that of commercial strain gauges, is much larger due to their higher gauge factors (-23.5), when compared to the GFs of commercial sensors (2).