6 resultados para Posner paradigm
em CiencIPCA - Instituto Politécnico do Cávado e do Ave, Portugal
Resumo:
Recent progresses in the software development world has assisted a change in hardware from heavy mainframes and desktop machines to unimaginable small devices leading to the prophetic "third computing paradigm", Ubiquitous Computing. Still, this novel unnoticeable devices lack in various capabilities, like computing power, storage capacity and human interface. Connectivity associated to this devices is also considered an handicap which comes generally associated expensive and limited protocols like GSM and UMTS. Considering this scenario as background, this paper presents a minimal communication protocol introducing better interfaces for limited devices. Special attention has been paid to the limitations of connectivity, storage capacity and scalability of the developed software applications. Illustrating this new protocol, a case-study is presented addressing car sensors communicating with a central
Resumo:
Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques
Resumo:
Over the last decade component-based software development arose as a promising paradigm to deal with the ever increasing complexity in software design, evolution and reuse. SHACC is a prototyping tool for component-based systems in which components are modelled coinductively as generalized Mealy machines. The prototype is built as a HASKELL library endowed with a graphical user interface developed in Swing
Resumo:
Image segmentation is an ubiquitous task in medical image analysis, which is required to estimate morphological or functional properties of given anatomical targets. While automatic processing is highly desirable, image segmentation remains to date a supervised process in daily clinical practice. Indeed, challenging data often requires user interaction to capture the required level of anatomical detail. To optimize the analysis of 3D images, the user should be able to efficiently interact with the result of any segmentation algorithm to correct any possible disagreement. Building on a previously developed real-time 3D segmentation algorithm, we propose in the present work an extension towards an interactive application where user information can be used online to steer the segmentation result. This enables a synergistic collaboration between the operator and the underlying segmentation algorithm, thus contributing to higher segmentation accuracy, while keeping total analysis time competitive. To this end, we formalize the user interaction paradigm using a geometrical approach, where the user input is mapped to a non-cartesian space while this information is used to drive the boundary towards the position provided by the user. Additionally, we propose a shape regularization term which improves the interaction with the segmented surface, thereby making the interactive segmentation process less cumbersome. The resulting algorithm offers competitive performance both in terms of segmentation accuracy, as well as in terms of total analysis time. This contributes to a more efficient use of the existing segmentation tools in daily clinical practice. Furthermore, it compares favorably to state-of-the-art interactive segmentation software based on a 3D livewire-based algorithm.
Resumo:
Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques.
Resumo:
In the 70s, a new line of research focused on the study of the influence of the audit report on the decision process of investors, financial analysts and credit analysts. Notwithstanding the numerous studies that have been carried out, results have not been consistent. Given the above, and considering the lack, in Portugal, of a research of this nature, it seems urgent to carry out a study that allows the analysis of the use of the audit report, as well as its influence on the decision making process of Portuguese stakeholders. For that purpose, in the light of the positivist research paradigm, a questionnaire was designed, which was administered by mail and on the Survey Monkey platform to a sample of institutional investors, financial analysts and credit analysts. The statistical analysis of the data obtained was undertaken with resource to the Statistical Package for the Social Sciences and SmartPLS 2.0. Corroborating the literature review and the assumptions of the Agency Theory and the Stakeholder Theory, used in the theoretical framework of analysis, empirical evidence has shown that the audit report influences the decision of institutional investors, financial analysts and credit analysts, and that the opinion expressed in that document is the most determinant factor of this influence. In addition to this factor, it was found that the degree of utilization of the audit report, as well as the value ascribed to this document, determine its influence in the decision process of research groups studied. Only in the case of institutional investors, the results did not reveal a correlation between the utility ascribed to the audit report and the influence of this document in their decision making process. In turn, the statistical inference of the model explaining the degree of use of the audit report revealed that it is conditioned by the perceived quality of the information enclosed in the audit report, the utility assigned to the audit report on the decision process, as well as the relevance of the other sources of information used by stakeholders. Therefore, this study allowed proving the importance of the audit report to its users. As a result, we believe to have filled a gap in national literature and to have contributed to the enhancement of international literature. The importance that this document has for the development of any country is, therefore, shown, and it is urgent to maintain rigor in the selection of its staff, in the development of its standards, and especially in the development of audits. Moreover, we also consider that this research may contribute to the improvement of the audit report, insofar as it will help professional bodies to understand the information needs and perceptions of stakeholders.