4 resultados para Neurological Outpatient Referrals
em CiencIPCA - Instituto Politécnico do Cávado e do Ave, Portugal
Resumo:
Digital thermal imaging has been employed in medicine for over 50 years. However, its use has been focused on vascular, musculoskeletal and neurological conditions, while other potential applications,such as obstetrics, have been much less explored. This paper presents a study conducted during 2011 at the Hospital of Braga on a group of healthy pregnant women in the last third of gestation. The analysis focused on characterizing typical pregnant women steady temperature profiles in specific defined regions of interest (ROI), and determining if the thermal symmetry values for late pregnant healthy women are in line with the values for non-pregnant healthy women. A temperature distribution pattern was found in the defined ROI. The obtained thermal symmetry value had a maximum of 0.370.2 1C, and there was no evidence for the influence of age (p40.05) in the observed group. The influence of the BMI requires further investigation since one ROI (P2 right) presented a p¼0.059, close to the threshold of statistical evidence in the influence of BMI. The study group presented symmetry values in line with non-pregnant reference values, but the profiles in temperature distribution are different. Assumptions can therefore now be used with higher confidence when assessing abnormalities in specific pathologic states during pregnancy using the defined ROI. This work represents a first contribution towards establishing guidelines for future research in this specific field of study.
Resumo:
In the last decade, population ageing has been registered as a global phenomenon. A relation exists between falling and ageing, since falling frequency increases significantly with age. In fact, one in three older adult falls annually. Although ageing is generically associated with decrease and degeneration of psychological and physical functions, it is still not common for the correct identification of risk factors to lead to a clinical prognosis of the elder being in risk of falling. Therefore, the goal of this review article is to identify, categorise and analyse typical ageing and fall factors mentioned in the literature as well as to quantify the number of times they were referenced. The research considered hundreds of publications, but analysis was then restricted to the 87 most pertinent articles written in English and published in journals or scientific magazines between 1995 and 2010. We concluded that falls among older adults can be characterised by the following: anatomic characteristics and physiological consequences of ageing; the pathologies that induce falls, which can be neurological, musculoskeletal, cardiovascular and other diseases; causes and risk factors of falls that can be behavioural, biological, environmental or socio-economic; type of physical consequences of falls, including fractures, bruises, injuries or other physical consequences; and strategies to prevent, mitigate or rehabilitate, which can be of a physical, environmental or behavioural nature.
Resumo:
In the last decade, population ageing has been registered as a global phenomenon. A relation exists between falling and ageing, since falling frequency increases significantly with age. In fact, one in three older adult falls annually. Although ageing is generically associated with decrease and degeneration of psychological and physical functions, it is still not common for the correct identification of risk factors to lead to a clinical prognosis of the elder being in risk of falling. Therefore, the goal of this review article is to identify, categorise and analyse typical ageing and fall factors mentioned in the literature as well as to quantify the number of times they were referenced. The research considered hundreds of publications, but analysis was then restricted to the 87 most pertinent articles written in English and published in journals or scientific magazines between 1995 and 2010. We concluded that falls among older adults can be characterised by the following: anatomic characteristics and physiological consequences of ageing; the pathologies that induce falls, which can be neurological, musculoskeletal, cardiovascular and other diseases; causes and risk factors of falls that can be behavioural, biological, environmental or socio-economic; type of physical consequences of falls, including fractures, bruises, injuries or other physical consequences; and strategies to prevent, mitigate or rehabilitate, which can be of a physical, environmental or behavioural nature.
Resumo:
Hand and finger tracking has a major importance in healthcare, for rehabilitation of hand function required due to a neurological disorder, and in virtual environment applications, like characters animation for on-line games or movies. Current solutions consist mostly of motion tracking gloves with embedded resistive bend sensors that most often suffer from signal drift, sensor saturation, sensor displacement and complex calibration procedures. More advanced solutions provide better tracking stability, but at the expense of a higher cost. The proposed solution aims to provide the required precision, stability and feasibility through the combination of eleven inertial measurements units (IMUs). Each unit captures the spatial orientation of the attached body. To fully capture the hand movement, each finger encompasses two units (at the proximal and distal phalanges), plus one unit at the back of the hand. The proposed glove was validated in two distinct steps: a) evaluation of the sensors’ accuracy and stability over time; b) evaluation of the bending trajectories during usual finger flexion tasks based on the intra-class correlation coefficient (ICC). Results revealed that the glove was sensitive mainly to magnetic field distortions and sensors tuning. The inclusion of a hard and soft iron correction algorithm and accelerometer and gyro drift and temperature compensation methods provided increased stability and precision. Finger trajectories evaluation yielded high ICC values with an overall reliability within application’s satisfying limits. The developed low cost system provides a straightforward calibration and usability, qualifying the device for hand and finger tracking in healthcare and animation industries.