5 resultados para Monitoring tool
em CiencIPCA - Instituto Politécnico do Cávado e do Ave, Portugal
Resumo:
ZigBee-based Remote Patient Monitoring
Resumo:
Graphical user interfaces (GUIs) are critical components of today's software. Developers are dedicating a larger portion of code to implementing them. Given their increased importance, correctness of GUIs code is becoming essential. This paper describes the latest results in the development of GUISurfer, a tool to reverse engineer the GUI layer of interactive computing systems. The ultimate goal of the tool is to enable analysis of interactive system from source code.
Resumo:
More and more current software systems rely on non trivial coordination logic for combining autonomous services typically running on different platforms and often owned by different organizations. Often, however, coordination data is deeply entangled in the code and, therefore, difficult to isolate and analyse separately. COORDINSPECTOR is a software tool which combines slicing and program analysis techniques to isolate all coordination elements from the source code of an existing application. Such a reverse engineering process provides a clear view of the actually invoked services as well as of the orchestration patterns which bind them together. The tool analyses Common Intermediate Language (CIL) code, the native language of Microsoft .Net Framework. Therefore, the scope of application of COORDINSPECTOR is quite large: potentially any piece of code developed in any of the programming languages which compiles to the .Net Framework. The tool generates graphical representations of the coordination layer together and identifies the underlying business process orchestrations, rendering them as Orc specifications
Resumo:
Purpose – Castings defects are usually easy to characterize, but to eradicate them can be a difficult task. In many cases, defects are caused by the combined effect of different factors, whose identification is often difficult. Besides, the real non-quality costs are usually unknown, and even neglected. This paper aims to describe the development of a modular tool for quality improvement in foundries, and its main objective is to present the application potential and the foundry process areas that are covered and taken into account. Design/methodology/approach – The integrated model was conceived as an expert system, designated Qualifound, which performs both qualitative and quantitative analyses. For the qualitative analyses mode, the nomenclature and the description of defects are based on the classification suggested by the International Committee of the Foundry Technical Association. Thus, a database of defects was established, enabling one to associate the defects with the relevant process operations and the identification of their possible causes. The quantitative analysis mode deals with the number of produced and rejected castings and includes the calculation of the non-quality costs. Findings – The validation of Qualifound was carried out in a Portuguese foundry, whose quality system had been certified according to the ISO 9000 standards. Qualifound was used in every management area and it was concluded that the application had the required technological requisites to provide the necessary information for the foundry management to improve process quality. Originality/value – The paper presents a successful application of an informatics tool on quality improvement in foundries.
Resumo:
AIM: This work presents detailed experimental performance results from tests executed in the hospital environment for Health Monitoring for All (HM4All), a remote vital signs monitoring system based on a ZigBee® (ZigBee Alliance, San Ramon, CA) body sensor network (BSN). MATERIALS AND METHODS: Tests involved the use of six electrocardiogram (ECG) sensors operating in two different modes: the ECG mode involved the transmission of ECG waveform data and heart rate (HR) values to the ZigBee coordinator, whereas the HR mode included only the transmission of HR values. In the absence of hidden nodes, a non-beacon-enabled star network composed of sensing devices working on ECG mode kept the delivery ratio (DR) at 100%. RESULTS: When the network topology was changed to a 2-hop tree, the performance degraded slightly, resulting in an average DR of 98.56%. Although these performance outcomes may seem satisfactory, further investigation demonstrated that individual sensing devices went through transitory periods with low DR. Other tests have shown that ZigBee BSNs are highly susceptible to collisions owing to hidden nodes. Nevertheless, these tests have also shown that these networks can achieve high reliability if the amount of traffic is kept low. Contrary to what is typically shown in scientific articles and in manufacturers' documentation, the test outcomes presented in this article include temporal graphs of the DR achieved by each wireless sensor device. CONCLUSIONS: The test procedure and the approach used to represent its outcomes, which allow the identification of undesirable transitory periods of low reliability due to contention between devices, constitute the main contribution of this work.