3 resultados para Medical equipment.
em CiencIPCA - Instituto Politécnico do Cávado e do Ave, Portugal
Resumo:
Wireless medical systems are comprised of four stages, namely the medical device, the data transport, the data collection and the data evaluation stages. Whereas the performance of the first stage is highly regulated, the others are not. This paper concentrates on the data transport stage and argues that it is necessary to establish standardized tests to be used by medical device manufacturers to provide comparable results concerning the communication performance of the wireless networks used to transport medical data. Besides, it suggests test parameters and procedures to be used to produce comparable communication performance results.
Resumo:
In medical emergency situations, when a patient needs a blood transfusion, the universal blood type O− is administered. This procedure may lead to the depletion of stock reserves of O− blood. Nowadays, there is no commercial equipment capable of determining the patient's blood type in situ, in a fast and reliable process. Human blood typing is usually performed through the manual test, which involves a macroscopic observation and interpretation of the results by an analyst. This test, despite of having a fast response time, may lead to human errors, which sometimes can be fatal to the patient. This paper presents the development of an automatic mechatronic prototype for determining human blood typing (ABO and Rh systems) through image processing techniques. The prototype design takes into account the characteristics of reliability of analysis, portability, and response time allowing the system to be used in emergency situations. The developed prototype performs blood and reagents mixture acquires the resultant image and processes the data (based on image processing techniques) to determine the sample blood type. It was tested in a laboratory, using cataloged samples of blood types, provided by the Portuguese Institute of Blood and Transplantation. Hereafter, it is expected to test and validate the prototype in clinical environments.
Resumo:
1 – Summary of the decision taken by the Portuguese Constitutional Court, of January 13, 2011; 2 – Complete text of the decision of the Portuguese Constitutional Court, of January 13, 2011, Judge Maria João ANTUNES (Reporter), Judge Carlos Pamplona de OLIVEIRA, Judge José Borges SOEIRO, Judge Gil GALVÃO, Judge Rui Manuel Moura RAMOS (President) –in terms of the tribunalconstitucional.pt, August 1, 2011; 3 – Brief annotation to the problem of the “medical act”; 3.1 – Plus some conclusions on the brief annotation to the problem of the “medical act”; 3.2 – Brief annotation to the problem of “consent”– continuation of the previous comments; 4 – Conclusions. It must never be forgotten that “consent” does not stand as the only cause of exclusion of unlawfulness.