6 resultados para Innovative monitoring techniques
em CiencIPCA - Instituto Politécnico do Cávado e do Ave, Portugal
Resumo:
Purpose – The health and social care sector is receiving growing attention due to the increased life expectancy and to the public demand for a better quality of life and better health services. New cost-efficient approaches are required, and the paper aims to present and discuss the main results of a study undertaken in a Portuguese municipality on the perceived relevance of an e-marketplace of social and healthcare services for the inhabitants in general, and for people with special needs in particular, and the identification of the most relevant services to be offered through this platform. Design/methodology/approach – A wide survey was undertaken to identify the needs of potential users and their expectancies with relation to the proposed platform. The results of the study are a support for the project promoters to understand the viability of the solution and the requirements to the deployment of the pilot experiment, as well as to drive the selection of domains of activities/classes of services to be offered by the platform. Findings – Services such as information about healthcare services, home monitoring/accompanying services 24 hours per day, and personal hygiene services provided at home are the ones recognized by the inquired citizens as the most important, which indicates that the potential users will be mostly people with special needs or their family or caregivers. Originality/value – While still at a preliminary development phase, the project represents a good opportunity to develop a totally innovative service with high potential impact for the senior population and for individuals with special needs.
Resumo:
ZigBee-based Remote Patient Monitoring
Resumo:
Chronic stress impairs cognitive function, namely on tasks that rely on the integrity of cortico-limbic networks. To unravel the functional impact of progressive stress in cortico-limbic networks we measured neural activity and spectral coherences between the ventral hippocampus (vHIP) and the medial prefrontal cortex (mPFC) in rats subjected to short term stress (STS) and chronic unpredictable stress (CUS). CUS exposure consistently disrupted the spectral coherence between both areas for a wide range of frequencies, whereas STS exposure failed to trigger such effect. The chronic stress-induced coherence decrease correlated inversely with the vHIP power spectrum, but not with the mPFC power spectrum, which supports the view that hippocampal dysfunction is the primary event after stress exposure. Importantly, we additionally show that the variations in vHIP-to-mPFC coherence and power spectrum in the vHIP correlated with stress-induced behavioral deficits in a spatial reference memory task. Altogether, these findings result in an innovative readout to measure, and follow, the functional events that underlie the stress-induced reference memory impairments.
Resumo:
The evolution of computer animation represents one of the most relevant andrevolutionary aspects in the rise of contemporary digital visual culture (Darlew,2000), in particular, phenomena such as cinema “spectacular “ (Ibidem) and videogames. This article analyzes the characteristics of this “culture of simulation” (Turkle, 1995:20) relating the multidisciplinary and spectrum of technical and stylistic choices to the dimension of virtual characters acting. The result of these hybrid mixtures and computerized human motion capture techniques - called virtual cinema, universal capture, motion capture, etc. - cosists mainly on the sophistication of “rotoscoping”, as a new interpretation and appropriation of the captured image. This human motion capture technology, used largely by cinema and digital games, is one of the reasons why the authenticity of the animation is sometimes questioned. It is in the fi eld of 3D computer animation visual that this change is more signifi cant, appearing regularly innovative techniques of image manipulation and “hyper-cinema” (Lamarre, 2006: 31) character’s control with deeper sense of emotions. This shift in the culture that Manovich (2006: 27) calls “photo-GRAPHICS” - and Mulvey (2007) argue that creates a new form of possessive relationship with the viewer, in that it can analyze in detail the image, it can acquire it and modify it - is one of the most important aspects in the rise of Cubbit’s (2007) “cinema of attraction”. This article delves intrinsically into the analyze of virtual character animation — particularly in the fi eld of 3D computer animation and human digital acting.
Resumo:
AIM: This work presents detailed experimental performance results from tests executed in the hospital environment for Health Monitoring for All (HM4All), a remote vital signs monitoring system based on a ZigBee® (ZigBee Alliance, San Ramon, CA) body sensor network (BSN). MATERIALS AND METHODS: Tests involved the use of six electrocardiogram (ECG) sensors operating in two different modes: the ECG mode involved the transmission of ECG waveform data and heart rate (HR) values to the ZigBee coordinator, whereas the HR mode included only the transmission of HR values. In the absence of hidden nodes, a non-beacon-enabled star network composed of sensing devices working on ECG mode kept the delivery ratio (DR) at 100%. RESULTS: When the network topology was changed to a 2-hop tree, the performance degraded slightly, resulting in an average DR of 98.56%. Although these performance outcomes may seem satisfactory, further investigation demonstrated that individual sensing devices went through transitory periods with low DR. Other tests have shown that ZigBee BSNs are highly susceptible to collisions owing to hidden nodes. Nevertheless, these tests have also shown that these networks can achieve high reliability if the amount of traffic is kept low. Contrary to what is typically shown in scientific articles and in manufacturers' documentation, the test outcomes presented in this article include temporal graphs of the DR achieved by each wireless sensor device. CONCLUSIONS: The test procedure and the approach used to represent its outcomes, which allow the identification of undesirable transitory periods of low reliability due to contention between devices, constitute the main contribution of this work.
Resumo:
Background: Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose: The aim of this study was to identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods: A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit.A total of 417 articles were identified; 32 were selected for review. Results: All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique, and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in nine; six studies tested vinyl polysiloxane and one study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intraoral optical devices were compared in four studies. Conclusions: The most accurate results were achieved with two configurations: (1) the optical intraoral system with powder and (2) the open technique with splinted squared transfer copings, using polyether as impression material.