2 resultados para Flow Stability

em CiencIPCA - Instituto Politécnico do Cávado e do Ave, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: to evaluate and study the viability, stability and the ability of the Portuguese Football Federation (PFF) to generate sustained profits. Methodology: Data were collected based on the Audit Reports of the institution during 2012-2014 and a financial and economic analysis was performed in order to establish some indicators of solvability, profitability and financial balance. Findings: It exists a lack of consistency in managing the profits obtained. We can also suggest that should be given a greater interest to the management of their own intangible assets, as brand management, for example. Practical implications: By making known to leaders and managers of this type of institutions that exists a link between participation in international championships and increase of their profitability may encourage them to better managing these cash inputs in order to decrease the dependence of Governmental financing. We also found that the management of their own intangible assets, as brand management, for example, could probably add more positive financial results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In daily cardiology practice, assessment of left ventricular (LV) global function using non-invasive imaging remains central for the diagnosis and follow-up of patients with cardiovascular diseases. Despite the different methodologies currently accessible for LV segmentation in cardiac magnetic resonance (CMR) images, a fast and complete LV delineation is still limitedly available for routine use. In this study, a localized anatomically constrained affine optical flow method is proposed for fast and automatic LV tracking throughout the full cardiac cycle in short-axis CMR images. Starting from an automatically delineated LV in the end-diastolic frame, the endocardial and epicardial boundaries are propagated by estimating the motion between adjacent cardiac phases using optical flow. In order to reduce the computational burden, the motion is only estimated in an anatomical region of interest around the tracked boundaries and subsequently integrated into a local affine motion model. Such localized estimation enables to capture complex motion patterns, while still being spatially consistent. The method was validated on 45 CMR datasets taken from the 2009 MICCAI LV segmentation challenge. The proposed approach proved to be robust and efficient, with an average distance error of 2.1 mm and a correlation with reference ejection fraction of 0.98 (1.9 ± 4.5%). Moreover, it showed to be fast, taking 5 seconds for the tracking of a full 4D dataset (30 ms per image). Overall, a novel fast, robust and accurate LV tracking methodology was proposed, enabling accurate assessment of relevant global function cardiac indices, such as volumes and ejection fraction.