3 resultados para Flow Regime

em Repositório da Universidade Federal do Espírito Santo (UFES), Brazil


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial contractility depends on several mechanisms such as coronary perfusion pressure (CPP) and flow as well as on a1-adrenoceptor stimulation. Both effects occur during the sympathetic stimulation mediated by norepinephrine. Norepinephrine increases force development in the heart and produces vasoconstriction increasing arterial pressure and, in turn, CPP. The contribution of each of these factors to the increase in myocardial performance needs to be clarified. Thus, in the present study we used two protocols: in the first we measured mean arterial pressure, left ventricular pressure and rate of rise of left ventricular pressure development in anesthetized rats (N = 10) submitted to phenylephrine (PE) stimulation before and after propranolol plus atropine treatment. These observations showed that in vivo a1-adrenergic stimulation increases left ventricular-developed pressure (P<0.05) together with arterial blood pressure (P<0.05). In the second protocol, we measured left ventricular isovolumic systolic pressure (ISP) and CPP in Langendorff constant flow-perfused hearts. The hearts (N = 7) were perfused with increasing flow rates under control conditions and PE or PE + nitroprusside (NP). Both CPP and ISP increased (P<0.01) as a function of flow. CPP changes were not affected by drug treatment but ISP increased (P<0.01). The largest ISP increase was obtained with PE + NP treatment (P<0.01). The results suggest that both mechanisms, i.e., direct stimulation of myocardial a1-adrenoceptors and increased flow, increased cardiac performance acting simultaneously and synergistically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work discusses the use of optical flow to generate the sensorial information a mobile robot needs to react to the presence of obstacles when navigating in a non-structured environment. A sensing system based on optical flow and time-to-collision calculation is here proposed and experimented, which accomplishes two important paradigms. The first one is that all computations are performed onboard the robot, in spite of the limited computational capability available. The second one is that the algorithms for optical flow and time-to-collision calculations are fast enough to give the mobile robot the capability of reacting to any environmental change in real-time. Results of real experiments in which the sensing system here proposed is used as the only source of sensorial data to guide a mobile robot to avoid obstacles while wandering around are presented, and the analysis of such results allows validating the proposed sensing system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O conhecimento do regime natural de rios é relevante, entre diversas razões, para avaliar o impacto antrópico em bacias hidrográficas. Desta forma, visa criar ferramentas que auxiliem no planejamento eficiente dos recursos hídricos. O rio Santa Maria da Vitória (ES) é crucial para o desenvolvimento socioeconômico da Região Metropolitana da Grande Vitória. Adicionalmente, diversos ecossistemas e comunidades agrícolas dependem deste rio. Sendo a geração de energia elétrica um dos usos mais significativos do rio Santa Maria da Vitória, através das Pequenas Centrais Hidrelétricas Rio Bonito e Suíça, o objetivo principal desta pesquisa foi buscar uma melhor compreensão da influência da operação destes empreendimentos na vazão natural deste rio. Além da análise das séries de vazões e de precipitações medidas em Santa Leopoldina, comparando o período anterior com o posterior à implantação das PCH`s, realizou-se a reconstituição das vazões naturais médias diárias e médias mensais a jusante das PCH`s, através da técnica de extensão MOVE.I (tipo 1) e com o auxílio da série de vazão medida na estação fluviométrica Marechal Floriano, localizada na bacia hidrográfica do rio Jucu. Os resultados obtidos, a partir dos dados monitorados na estação Santa Leopoldina, mostraram uma diminuição nas vazões mínimas com 7, 30 e 90 dias de duração para o período pós-regulado. Ainda, as vazões de permanência Q50, Q90 e Q95 e a vazão média de longa duração reconstituídas são menores que as vazões observadas em Santa Leopoldina. Além da presença das PCH`s, as alterações no uso e cobertura do solo da bacia podem ter influência sobre os resultados encontrados. As vazões em Santa Leopoldina, devido aos horários em que são realizadas as medições, podem não representar de forma confiável as oscilações a jusante das PCH`s. Consequentemente, faz-se necessário um monitoramento contínuo das vazões a jusante desses empreendimentos e recomenda-se que seja realizada uma nova reconstituição das vazões naturais do rio Santa Maria da Vitória, através do balanço hídrico dos reservatórios, utilizando os dados operativos das PCH`s.