3 resultados para PVC-aren degradazioa
em Instituto de Engenharia Nuclear, Brazil - Carpe dIEN
Resumo:
In industrial plants, oil and oil compounds are usually transported by closed pipelines with circular cross-section. The use of radiotracers in oil transport and processing industrial facilities allows calibrating flowmeters, measuring mean residence time in cracking columns, locate points of obstruction or leak in underground ducts, as well as investigating flow behavior or industrial processes such as in distillation towers. Inspection techniques using radiotracers are non-destructive, simple, economic and highly accurate. Among them, Total Count, which uses a small amount of radiotracer with known activity, is acknowledged as an absolute technique for flow rate measurement. A viscous fluid transport system, composed by four PVC pipelines with 13m length (12m horizontal and 1m vertical) and ½, ¾, 1 and 2-inch gauges, respectively, interconnected by maneuvering valves was designed and assembled in order to conduct the research. This system was used to simulate different flow conditions of petroleum compounds and for experimental studies of flow profile in the horizontal and upward directions. As 198Au presents a single photopeak (411,8 keV), it was the radioisotope chosen for oil labeling, in small amounts (6 ml) or around 200 kBq activity, and it was injected in the oil transport lines. A NaI scintillation detector 2”x 2”, with well-defined geometry, was used to measure total activity, determine the calibration factor F and, positioned after a homogenization distance and interconnected to a standardized electronic set of nuclear instrumentation modules (NIM), to detect the radioactive cloud.
Resumo:
In this study, it was developed a methodology for the determination of the dispersion of a gaseous tracer in porous media using the radiotracer technique. In order to evaluate several porous media, a cylindrical filter was constructed in PVC and connected to a system with constant flow. Inside this unit silica crystals (16-20) mesh was used as porous media and CH3Br (Methyl Bromide) marked with 82Br was used as radiotracer. An instantaneous pulse of tracer was applied in the system entrance and registered by two NaI (3x3)” scintillation detectors located one before and the other after the filter. The curves produced by the radioactive cloud and recorded by the detector were analyzed statistically using the weighted moment method. The mathematical model one considered as great dispersion of tracer was used to evaluate the flow conditions inside the filter system. The results show us that the weight moment method associated with radiotracer techniques is useful to evaluated an industrial filter and allows to measure the residence time distribution, τ, and the axial dispersion, DAB, gas in a porous medium.
Resumo:
O projeto e desenvolvimento de uma nova linha de feixe dotada de um sistema que viabilize a irradiação no Cíclotron CV-28 do Instituto de Engenharia Nuclear de alvos extensos e de geometria variável tornaram-se necessário para a realização de estudos e desenvolvimento de aplicações de técnicas nucleares e análises de materiais por ativação em condições de irradiação até então não disponíveis. Este sistema que poderá ser utilizado em irradiações com feixes de prótons, alfas, deutério e hélions (He3) a energias variáveis, é composto por dispositivos de: proteção, interceptação, colimação e medição da intensidade do feixe, de forma a possibilitar a realização de irradiações em condições controláveis e reprodutíveis. Para tanto, peças em alumínio e PVC-foram usinadas de forma a construir os componentes do sistema, notadamente colimadores com 13mm e 9mm de diâmetro, um dispositivo de colimação de quatro setores, um "beam stop", duas flanges de isolamento elétrico e um porta alvo (com janela degradadora). Identificou-se também a necessidade de se dotar o sistema aqui desenvolvido de um circuito de refrigeração próprio à água deionizada que é responsável pela refrigeração de todos os seus componentes que possam ter contato com o feixe. O sistema conta ainda com conexões para vácuo, que possibilitam fazer um pré-vácuo em sua câmara de irradiação, de forma que a mesma possa interligada a linha de transporte de feixe de Cíclotron CV-28, sem causar danos ao vácuo do mesmo. A condição para se fazer esta interligação é a obtenção de um pré-vácuo no ordem de 10-4 torr. Os resultados experimentais obtidos com a realização de irradiações de alvos metálicos especialmente desenvolvidos para testar o sistema, que é tema da presente dissertação, atestam a confiabilidade e reprodutibilidade das condições de irradiação, o que viabilizam o desenvolvimento e emprego de novas unidades de irradiação a serem incorporadas ao mesmo. Esse sistema de irradiação já está sendo utilizado na linha 2 do CV-28