6 resultados para working length

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the accuracy of electronic apex locators Digital Signal Processing (DSP) and ProPex, for root canal length determination in primary teeth. Fifteen primary molars (a total of 34 root canals) were divided into two groups: Group I - without physiological resorption (n = 16); and Group II - with physiological resorption (n = 18). The length of each canal was measured by introducing a file until its tip was visible and then it was retracted 1 mm. For electronic measurement, the devices were set to 1 mm short of the apical resorption. The data were analysed statistically using the intraclass correlation coefficient (ICC). Results showed that the ICC was high for both electronic apex locators in all situations - with (ICC: DSP = 0.82 and Propex = 0.89) or without resorption (ICC: DSP = 0.92 and Propex = 0.90). Both apex locators were extremely accurate in determining the working length in primary teeth, both with or without physiological resorption.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to evaluate ex vivo the accuracy an electronic apex locator during root canal length determination in primary molars. Methods: One calibrated examiner determined the root canal length in 15 primary molars (total=34 root canals) with different stages of root resorption. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using an electronic apex locator (Digital Signal Processing). Data were analyzed statistically using the intraclass correlation (ICC) test. Results: Comparing the actual and electronic root canal length measurements in the primary teeth showed a high correlation (ICC=0.95) Conclusions: The Digital Signal Processing apex locator is useful and accurate for apex foramen location during root canal length measurement in primary molars. (Pediatr Dent 200937:320-2) Received April 75, 2008 vertical bar Lost Revision August 21, 2008 vertical bar Revision Accepted August 22, 2008

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sodium hypochlorite solution is toxic to vital tissues, causing severe effects if extruded during endodontic treatment. This paper presents a report on the tissue damage related to inadvertent extrusion of concentrated sodium hypochlorite solution during root canal treatment. A 65-year-old woman was referred with moderate pain, ecchymosis, and severe swelling of the right side of the face. These symptoms appeared immediately after a root canal treatment of the maxillary right canine, which had been started 21 hours earlier. It was diagnosed as air emphysema related to sodium hypochlorite solution extravasation during the endodontic treatment. To avoid this, an initial radiograph should be taken to determine the correct canal working length and confirm root canal integrity. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e46-e49)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

P>Aim To evaluate ex vivo the accuracy of the iPex multi-frequency electronic apex locator (NSK Ltd, Tokyo, Japan) for working length determination in primary molar teeth. Methodology One calibrated examiner determined the working length in 20 primary molar teeth (total of 33 root canals). Working length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the most coronal limit of root resorption, and electronically using the electronic apex locator iPex, according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual and the electronic measurements revealed high correlation (ICC = 0.99) between the methods, regardless of the presence or absence of physiological root resorption. Conclusions In this laboratory study, the iPex accurately identified the apical foramen or the apical opening location for working length measurement in primary molar teeth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous studies found students who both work and attend school undergo a partial sleep deprivation that accumulates across the week. The aim of the present study was to obtain information using a questionnaire on a number of variables (e.g., socio-demographics, lifestyle, work timing, and sleep-wake habits) considered to impact on sleep duration of working (n = 51) and non-working (n = 41) high-school students aged 14-21 yrs old attending evening classes (19:00-22:30h) at a public school in the city of Sao Paulo, Brazil. Data were collected for working days and days off. Multiple linear regression analyses were performed to assess the factors associated with sleep duration on weekdays and weekends. Work, sex, age, smoking, consumption of alcohol and caffeine, and physical activity were considered control variables. Significant predictors of sleep duration were: work (p < 0.01), daily work duration (8-10h/day; p < 0.01), sex (p = 0.04), age 18-21 yrs (0.01), smoking (p = 0.02) and drinking habits (p = 0.03), irregular physical exercise (p < 0.01), ease of falling asleep (p = 0.04), and the sleep-wake cycle variables of napping (p < 0.01), nocturnal awakenings (p < 0.01), and mid-sleep regularity (p < 0.01). The results confirm the hypotheses that young students who work and attend school showed a reduction in night-time sleep duration. Sleep deprivation across the week, particularly in students working 8-10h/day, is manifested through a sleep rebound (i.e., extended sleep duration) on Saturdays. However, the different roles played by socio-demographic and lifestyle variables have proven to be factors that intervene with nocturnal sleep duration. The variables related to the sleep-wake cyclenaps and night awakeningsproved to be associated with a slight reduction in night-time sleep, while regularity in sleep and wake-up schedules was shown to be associated with more extended sleep duration, with a distinct expression along the week and the weekend. Having to attend school and work, coupled with other socio-demographic and lifestyle factors, creates an unfavorable scenario for satisfactory sleep duration.