2 resultados para walking speed

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arboreal and terrestrial habitats impose different constraints on tetrapod locomotion. We studied Polychrus acutirostris, a tree-dwelling lizard that also moves on the ground, in order to evaluate the effects of support incline and diameter on locomotion parameters. Limb movements of six specimens were filmed to quantify kinematic variables (velocity, stride frequency, stride length, and limb coordination) on distinct perch diameters (4.0, 1.5, 0.8 cm) and inclines (90, 45, and on level ground). The results show a notable slowness in arboreal habitat combined with a relatively fast locomotion when using the ground as temporary habitat. These animals developed walking trots mainly using lateral sequence. Non-symmetrical trots adopted at the highest velocities on the ground indicate difficulties of ""accommodation"" to the constraints imposed by this condition. Velocity generally decreases with the decreasing diameter, and with increasing incline, of the supports. Slowness, gaits favouring the body stability, elective role of the stride frequency in the modulation of the speed, and the role of the hindlimb in the force exchange to propel the body, constitute the main features of the locomotion pattern of P. acutirostris.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to comparatively evaluate the response of human pulps after cavity preparation with different devices. Deep class I cavities were prepared in sound mandibular premolars using either a high-speed air-turbine handpiece (Group 1) or an Er: YAG laser (Group 2). Following total acid etching and the application of an adhesive system, all cavities were restored with composite resin. Fifteen days after the clinical procedure, the teeth were extracted and processed for analysis under optical microscopy. In Group 1 in which the average for the remaining dentin thickness (RDT) between the cavity floor and the coronal pulp was 909.5 mu m, a discrete inflammatory response occurred in only one specimen with an RDT of 214 mu m. However, tissue disorganization occurred in most specimens. In Group 2 (average RDT = 935.2 mu m), the discrete inflammatory pulp response was observed in only one specimen (average RDT = 413 mu m). It may be concluded that the high-speed air-turbine handpiece caused greater structural alterations in the pulp, although without inducing inflammatory processes.