113 resultados para velocity test
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Objective. - The objective of this work was to verify if there was a difference in throwing speed performance between heavier and lighter weight categories in judo. Methods and subjects. - Sixteen (16) judoists 18 +/- 3 years old, eight considered in the lightweight category (< 66 kg) and eight considered in the heavyweight (> 73 kg) category, participated in the study after signing a term of informed consent. A force-velocity test was used to determine the anaerobic power, strength, and pedal speed for each subject. In addition, three trials of Nage-komi exercise, each comprised of a set of Osoto-gari (15s), Uchi-mata (15s) and Seoi-nage (15s) throws were performed by each subject to ascertain throwing speed. Throws within the sets were intersected by one period of three minutes passive rest, while the trials were separated by one period of 10 minutes passive rest. Heart rate and the greatest number of throws within each set were measured for three trials. One-way analysis of variance (Anova) was used to compare the number of throws between the two weight categories and a ""Student"" test when the difference was significant. A correlation was used to examine the link between the different parameters. Results. - The force-velocity test did not show a significant difference in pedal speed between the two categories. However, there was a significant difference between the two categories when throwing speed was measured by the number of throws (p < 0.05) executed during the Seoi-nage (p < 0.01) and Uchi-mata (p <0.05) techniques. There was however, no significant difference between the two categories in Osoto-gari technique. Conclusion. - The throwing speed of judoists represented by the number of throws is significantly different between the two categories. The lighter category has more speed than the heavier category using the arm technique (Seoi-nage), while the heavier category has more speed using the leg technique with half turn of the attacker`s body (Uchi-mata). As a result, throwing speed is related to the type of technique used and not weight category. (C) 2007 Elsevier Masson SAS. All rights reserved.
Resumo:
We analyzed the usefulness of a semi-tethered field running test (STR) and the relationships between indices of anaerobic power, anaerobic capacity and running performance in 9 trained male sprinters (22.2 +/- 2.9 yrs, 176 +/- 1 cm, 68.0 +/- 9.4 kg). STR involved an all out 120 m run attached to an apparatus that enabled power calculation from force and velocity measures. Subjects also carried out a cycloergometer Win-gate Anaerobic Test (WT), an all out 300 m run and had accessed their maximal accumulated oxygen deficit (MAOD) on a treadmill. Peak and mean powers attained in STR (1 720 +/- 221 and 1 391 +/- 201 W) were greater but significantly related (r=0.82; P<0.01) to those in the WT (808 +/- 130 and 603 +/- 87 W). In addition, power measures derived from the STR were stronger related to running performance compared to those from the WT (r=0.81-0.94 vs. 0.68-0.84; P<0.05). Relationships between MAOD and most power indices were only weak to moderate. These results support the usefulness of STR for specific power assessment in field running and suggest that anaerobic power and capacity are not related entities, irrespective of having been evaluated using similar or dissimilar exercise modes.
Resumo:
Background: The relation between left ventricular filing velocities determined by Doppler echocardiography and autonomic nervous system function assessed by heart rate variability (HRV) is unclear. The aim of this study was to evaluate the influence of the autonomic nervous system assessed by the time and frequency domain indices of HRV in the Doppler indices of left ventricular diastolic filling velocities in patients without heart disease. Methods: We studied 451 healthy individuals (255 female [56.4%]) with normal blood pressure, electrocardiogram, chest x-ray, and treadmill electrocardiographic exercise stress test results, with a mean age of 43 +/- 12 (range 15-82) years, who underwent transthoracic Doppler echocardiography and 24-hour electrocardiographic ambulatory monitoring. We studied indices of HRV on time (standard deviation [SD] of all normal sinus RR intervals during 24 hours, SD of averaged normal sinus RR intervals for all 5-minute segments, mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms) and frequency (low frequency, high frequency, very low frequency, low frequency/high frequency ratio) domains relative to peak flow velocity during rapid passive filling phase (E), atrial contraction (A), E/A ratio, E-wave deceleration time, and isovolumic relaxation time. Statistical analysis was performed with Pearson correlation and logistic regression. Results: Peak flow velocity during rapid passive filling phase (E) and atrial contraction (A), E/A ratio, and deceleration time of early mitral inflow did not demonstrate a significant correlation with indices of HRV in time and frequency domain. We found that the E/A ratio was < 1 in 45 individuals (10%). Individuals with an E/A ratio < 1 had lower indices of HRV in frequency domain (except low frequency/high frequency) and lower indices of the mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms in time domain. Logistic regression demonstrated that an E/A ratio < 1 was associated with lower HF. Conclusion: Individuals with no evidence of heart disease and an E/A ratio < 1 demonstrated a significant decrease in indexes of HRV associated with parasympathetic modulation. (J Am Soc Echocardiogr 2010;23: 762-5.)
Resumo:
The aim of this study was to evaluate the arterial and venous blood flow in women who underwent upper limb axillary dissection surgery for the treatment of breast cancer. Sixty women were divided into two groups: group 1 (G1)-30 women who underwent breast surgery with axillary dissection level II or III (55.6 +/- A 8.6 years); group 2 (G2)-control, 30 women with no breast cancer (57.4 +/- A 7.0 years). Blood flow profile was evaluated by a continuous wave ultrasound Doppler device (Nicolet Vascular Versalab SE(A (R))) with an 8 MHz probe. Axillary, brachial arteries and veins, arm circumference, volumes, and the ankle-brachial index (ABI) were examined. Wilcoxon test and Mann-Whitney tests were applied to analyze blood flow velocity intra-group and between G1 and G2, respectively. The G1 results showed no lymphedema and no peripheral arterial disease (ABI > 0.9). Moreover, the mean blood flow velocity of the vessels ipsilateral to the surgery was significantly higher than the contralateral ones for all vessels examined (P < 0.05). The mean velocity of blood flow of the vessels contralateral to surgery was significantly higher than the axillary artery in G2 (P < 0.05). It can be concluded that women who underwent axillary dissection due to breast cancer showed probable stenosis in the arterial and venous axillary and brachial vessels of the upper limb ipsilateral to the surgery, confirmed by the increase of blood flow velocity, and such obstruction might affect the limb contralateral to the operation site.
Resumo:
Este trabalho faz uma análise das estimativas de teores de umidade obtidas com o método Ground Penetrating Radar (GPR) comparativamente às determinadas com os métodos Time Domain Reflectometry (TDR) e gravimétrico. Os dados foram obtidos em dois experimentos diferentes: um experimento controlado em laboratório buscando reproduzir um meio homogêneo onde foram obtidas as medidas de umidade com GPR (antenas de 1 GHz) e TDR, e outro experimento de campo onde foram obtidos dados com GPR (antenas de 200 MHz) e de amostras de solos do local. Para a obtenção das estimativas a partir do método GPR foram analisados os eventos relativos à onda de transmissão direta entre as antenas, onda refratada criticamente e onda refletida em interfaces com diferentes propriedades elétricas.O GPR mostrou-se sensível às variações de umidades presentes nos dois experimentos e apresentou boa correlação com os dados obtidos com TDR (REQM de0,007 m³m-3) e das amostras (REQM de 0,039 m³m-3).
Resumo:
Standardized olfactory tests are now available to quantitatively assess disorders of olfaction. A Brazilian-Portuguese version of the University of Pennsylvania Smell Identification Test (UPSIT) is currently being developed specifically for the Brazilian population. The most recent Brazilian-Portuguese version of the UPSIT (UPSIT-Br2) was administered to 88 Brazilian subjects who had no history of neurological or otorhinolaryngological disease. UPSIT-Br2 scores decreased with age, were lower in men than in women, and were lower in subjects with lower income. The degree to which the poorer performance of subjects with lower socio-economic status reflects lack of familiarity with test items is not known. Although this version of the UPSIT provides a sensitive and useful test of smell function for the Brazilian population, a revision of some test items is needed to achieve comparable norms to those found using the North American UPSIT in the United States.
Resumo:
This study was aimed to evaluate and compare the pathogenicity of rabies virus isolated from bats and dogs, and to verify the efficacy of a commercial rabies vaccine against these isolates. For evaluation of pathogenicity, mice were inoculated by the intramuscular route (IM) with 500MICLD50/0.03mL of the viruses. The cross-protection test was performed by vaccinating groups of mice by the subcutaneous route and challenged through the intracerebral (IC) route. Isolates were fully pathogenic when inoculated by the IC route. When inoculated intramuscularly, the pathogenicity observed showed different death rates: 60.0% for the Desmodus rotundus isolate; 50.0% for dog and Nyctinomops laticaudatus isolates; 40.0% for Artibeus lituratus isolate; 9.5% Molossus molossus isolate; and 5.2% for the Eptesicus furinalis isolate. Mice receiving two doses of the vaccine and challenged by the IC route with the isolates were fully protected. Mice receiving only one dose of vaccine were partially protected against the dog isolate. The isolates from bats were pathogenic by the IC route in mice. However, when inoculated through the intramuscular route, the same isolates were found with different degrees of pathogenicity. The results of this work suggest that a commercial vaccine protects mice from infection with bat rabies virus isolates, in addition to a canine rabies virus isolate.
Resumo:
The aim of this study was to evaluate the ability of the BANA Test to detect different levels of Porphyromonas gingivalis, Treponema denticola and Tannerella forsythia or their combinations in subgingival samples at the initial diagnosis and after periodontal therapy. Periodontal sites with probing depths between 5-7 mm and clinical attachment level between 5-10 mm, from 53 subjects with chronic periodontitis, were sampled in four periods: initial diagnosis (T0), immediately (T1), 45 (T2) and 60 days (T3) after scaling and root planing. BANA Test and Checkerboard DNA-DNA hybridization identified red complex species in the subgingival biofilm. In all experimental periods, the highest frequencies of score 2 (Checkerboard DNA-DNA hybridization) for P. gingivalis, T. denticola and T. forsythia were observed when strong enzymatic activity (BANA) was present (p < 0.01). The best agreement was observed at initial diagnosis. The BANA Test sensitivity was 95.54% (T0), 65.18% (T1), 65.22% (T2) and 50.26% (T3). The specificity values were 12.24% (T0), 57.38% (T1), 46.27% (T2) and 53.48% (T3). The BANA Test is more effective for the detection of red complex pathogens when the bacterial levels are high, i.e. in the initial diagnosis of chronic periodontitis.
Resumo:
Gene clustering is a useful exploratory technique to group together genes with similar expression levels under distinct cell cycle phases or distinct conditions. It helps the biologist to identify potentially meaningful relationships between genes. In this study, we propose a clustering method based on multivariate normal mixture models, where the number of clusters is predicted via sequential hypothesis tests: at each step, the method considers a mixture model of m components (m = 2 in the first step) and tests if in fact it should be m - 1. If the hypothesis is rejected, m is increased and a new test is carried out. The method continues (increasing m) until the hypothesis is accepted. The theoretical core of the method is the full Bayesian significance test, an intuitive Bayesian approach, which needs no model complexity penalization nor positive probabilities for sharp hypotheses. Numerical experiments were based on a cDNA microarray dataset consisting of expression levels of 205 genes belonging to four functional categories, for 10 distinct strains of Saccharomyces cerevisiae. To analyze the method's sensitivity to data dimension, we performed principal components analysis on the original dataset and predicted the number of classes using 2 to 10 principal components. Compared to Mclust (model-based clustering), our method shows more consistent results.
Resumo:
Purpose: This study investigated the energy system contributions of judo athletes to the Special Judo Fitness Test (SJFT). Methods: Fourteen male judo athletes performed the SJFT, which comprised three periods of judo activity (A = 15 s, B and C = 30 s) interspersed with 10 s rest intervals. During this test, one athlete threw two others positioned 6 m from each other using the ippon-seoi-nage technique. The fractions of the aerobic, anaerobic alactic and anaerobic lactic systems were calculated based on oxygen uptake, the fast component of excess postexercise oxygen uptake, and changes in net blood lactate, respectively. The contribution of the three energy systems was compared using a repeated measures analysis of variance and Bonferroni's multiple comparisons test. Compound symmetry, or sphericity, was determined by Mauchly's test. A level of significance of 5% (P < .05) was adopted in all analyses. Results: The alactic energy system presented a higher (F = 20.9; P < .001; power observed = 1.0) contribution (86.8 +/- 23.6 kJ; 42.3 +/- 5.9%) during the test when compared with both aerobic (57.1 +/- 11.3 kJ; 28.2 +/- 2.9%) and lactic (58.9 +/- 12.1 kJ; 29.5 +/- 6.2%) energy systems (P < .001 for both comparisons). Conclusions: The higher alactic contribution seems to be a consequence of the high-intensity efforts performed during the test, and its intermittent nature. Thus, when using the SJFT, coaches are evaluating mainly their athletes' anaerobic alactic system, which can be considered to be the most predominant system contributing to the actions (techniques) performed in the match.
Resumo:
This study aimed to describe and compare the ventilation behavior during an incremental test utilizing three mathematical models and to compare the feature of ventilation curve fitted by the best mathematical model between aerobically trained (TR) and untrained ( UT) men. Thirty five subjects underwent a treadmill test with 1 km.h(-1) increases every minute until exhaustion. Ventilation averages of 20 seconds were plotted against time and fitted by: bi-segmental regression model (2SRM); three-segmental regression model (3SRM); and growth exponential model (GEM). Residual sum of squares (RSS) and mean square error (MSE) were calculated for each model. The correlations between peak VO2 (VO2PEAK), peak speed (Speed(PEAK)), ventilatory threshold identified by the best model (VT2SRM) and the first derivative calculated for workloads below (moderate intensity) and above (heavy intensity) VT2SRM were calculated. The RSS and MSE for GEM were significantly higher (p < 0.01) than for 2SRM and 3SRM in pooled data and in UT, but no significant difference was observed among the mathematical models in TR. In the pooled data, the first derivative of moderate intensities showed significant negative correlations with VT2SRM (r = -0.58; p < 0.01) and Speed(PEAK) (r = -0.46; p < 0.05) while the first derivative of heavy intensities showed significant negative correlation with VT2SRM (r = -0.43; p < 0.05). In UT group the first derivative of moderate intensities showed significant negative correlations with VT2SRM (r = -0.65; p < 0.05) and Speed(PEAK) (r = -0.61; p < 0.05), while the first derivative of heavy intensities showed significant negative correlation with VT2SRM (r= -0.73; p < 0.01), Speed(PEAK) (r = -0.73; p < 0.01) and VO2PEAK (r = -0.61; p < 0.05) in TR group. The ventilation behavior during incremental treadmill test tends to show only one threshold. UT subjects showed a slower ventilation increase during moderate intensities while TR subjects showed a slower ventilation increase during heavy intensities.
Resumo:
This paper presents a, simple two dimensional frame formulation to deal with structures undergoing large motions due to dynamic actions including very thin inflatable structures, balloons. The proposed methodology is based on the minimum potential energy theorem written regarding nodal positions. Velocity, acceleration and strain are achieved directly from positions, not. displacements, characterizing the novelty of the proposed technique. A non-dimensional space is created and the deformation function (change of configuration) is written following two independent mappings from which the strain energy function is written. The classical New-mark equations are used to integrate time. Dumping and non-conservative forces are introduced into the mechanical system by a rheonomic energy function. The final formulation has the advantage of being simple and easy to teach, when compared to classical Counterparts. The behavior of a bench-mark problem (spin-up maneuver) is solved to prove the formulation regarding high circumferential speed applications. Other examples are dedicated to inflatable and very thin structures, in order to test the formulation for further analysis of three dimensional balloons.
Resumo:
Multicomponent white cast iron is a new alloy that belongs to system Fe-C-Cr-W-Mo-V, and because of its excellent wear resistance it is used in the manufacture of hot rolling mills rolls. To date, this alloy has been processed by casting, powder metallurgy, and spray forming. The high-velocity oxyfuel process is now also considered for the manufacture of components with this alloy. The effects of substrate, preheating temperature, and coating thickness on bond strength of coatings have been determined. Substrates of AISI 1020 steel and of cast iron with preheating of 150 A degrees C and at room temperature were used to apply coatings with 200 and 400 mu m nominal thickness. The bond strength of coatings was measured with the pull-off test method and the failure mode by scanning electron microscopic analysis. Coatings with thickness of 200 mu m and applied on substrates of AISI 1020 steel with preheating presented bond strength of 87 +/- A 4 MPa.
Resumo:
The citrus greening (or huanglongbing) disease has caused serious problems in citrus crops around the world. An early diagnostic method to detect this malady is needed due to the rapid dissemination of Candidatus Liberibacter asiaticus (CLas) in the field. This analytical study investigated the fluorescence responses of leaves from healthy citrus plants and those inoculated with CLas by images from a stereomicroscope and also evaluated their potential for the early diagnosis of the infection caused by this bacterium. The plants were measured monthly, and the evolution of the bacteria on inoculated plants was monitored by real-time quantitative polymerase chain reaction (RT-qPCR) amplification of CLas sequences. A statistical method was used to analyse the data. The selection of variables from histograms of colours (colourgrams) of the images was optimized using a paired Student's t-test. The intensity of counts for green colours from images of fluorescence had clearly minor variations for healthy plants than diseased ones. The darker green colours were the indicators of healthy plants and the light colours for the diseased. The method of fluorescence images is novel for fingerprinting healthy and diseased plants and provides an alternative to the current method represented by PCR and visual inspection. A new, non-subjective pattern of analysis and a non-destructive method has been introduced that can minimize the time and costs of analyses.