13 resultados para transplant ex mortuo
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
The purpose of this study was to evaluate ex vivo the accuracy an electronic apex locator during root canal length determination in primary molars. Methods: One calibrated examiner determined the root canal length in 15 primary molars (total=34 root canals) with different stages of root resorption. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using an electronic apex locator (Digital Signal Processing). Data were analyzed statistically using the intraclass correlation (ICC) test. Results: Comparing the actual and electronic root canal length measurements in the primary teeth showed a high correlation (ICC=0.95) Conclusions: The Digital Signal Processing apex locator is useful and accurate for apex foramen location during root canal length measurement in primary molars. (Pediatr Dent 200937:320-2) Received April 75, 2008 vertical bar Lost Revision August 21, 2008 vertical bar Revision Accepted August 22, 2008
Resumo:
Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.
Resumo:
P>Aim To evaluate ex vivo the accuracy of the iPex multi-frequency electronic apex locator (NSK Ltd, Tokyo, Japan) for working length determination in primary molar teeth. Methodology One calibrated examiner determined the working length in 20 primary molar teeth (total of 33 root canals). Working length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the most coronal limit of root resorption, and electronically using the electronic apex locator iPex, according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual and the electronic measurements revealed high correlation (ICC = 0.99) between the methods, regardless of the presence or absence of physiological root resorption. Conclusions In this laboratory study, the iPex accurately identified the apical foramen or the apical opening location for working length measurement in primary molar teeth.
Resumo:
(Nectandra Rol. ex Rottb. (Lauraceae) in Mato Grosso do Sul State, Brazil). This paper presents the taxonomic study of the species of Nectandra from Mato Grosso do Sul. Eight species of Nectandra were identified through the morphological analyses of specimens collected in different regions from the State: N. amazonum Nees, N. cissiflora Nees, N. cuspidata Nees, N. falcifolia (Nees) J.A. Castigl. ex Mart. Crov. & Piccinini, N. gardneri Meisn., N. hihua (Ruiz & Pav.) Rohwer, N. megapotamica (Spreng.) Mez and N. psammophila Nees. Identification key, morphological descriptions, geographic distribution, habitat, fenologic aspect, taxonomic comments, and illustrations are presented.
Resumo:
The aim of this study was to research Candida dubliniensis among isolates present in a Brazilian yeast collection and to evaluate the main phenotypic methods for discrimination between C. albicans and C. dubliniensis from oral cavity. A total of 200 isolates, presumptively identified as C. albicans or C. dubliniensis obtained from heart transplant patients under immunosuppressive therapy, tuberculosis patients under antibiotic therapy, HIV-positive patients under antiretroviral therapy, and healthy subjects, were analyzed using the following phenotypic tests: formation and structural arrangement of chlamydospores on corn meal agar, casein agar, tobacco agar, and sunflower seed agar; growth at 45 degrees C; and germ tube formation. All strains were analyzed by polymerase chain reaction (PCR). In a preliminary screen for C. dubliniensis, 48 of the 200 isolates on corn meal agar, 30 of the 200 on casein agar, 16 of the 200 on tobacco agar, and 15 of the 200 on sunflower seed agar produced chlamydoconidia; 27 of the 200 isolates showed no or poor growth at 45 degrees C. All isolates were positive for germ tube formation. These isolates were considered suggestive of C. dubliniensis. All of them were subjected to PCR analysis using C. dubliniensis-specific primers. C. dubliniensis isolates were not found. C. dubliniensis isolates were not recovered in this study done with immunocompromised patients. Sunflower seed agar was the medium with the smallest number of isolates of C. albicans suggestive of C. dubliniensis. None of the phenotypic methods was 100% effective for discrimination between C. albicans and C. dubliniensis. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
A new genus and species of Normanellidae (Copepoda, Harpacticoida), Paranaiara inajae gen. et sp. nov., is described from the continental shelf off the northern coast of Sao Paulo State, Brazil. The new genus differs from the type genus Normanella Brady, 1880 and Sagamiella Lee & Huys, 1999 in its presence of lamelliform caudal rami, a maxillulary endopod represented by 2 setae, an unarmed maxillipedal syncoxa, and reduced setation on P2 enp-2 (without outer spine) and P3 enp-2 (with only 2 inner setae). All these apomorphic character states are shared with the genus Pseudocletodes Scott & Scott, 1893, formerly placed in the family Nannopodidae (ex Huntemanniidae) and here assigned to the Normanellidae. Pseudocletodes can be differentiated from Paranaiara by the loss of the P1 endopod and of the inner seta on P2-P4 enp-1, the presence of only 2 inner setae on P2 enp-2 (instead of 3) and only 1 inner seta on P4 exp-3 (instead of 2), the presence of a second inner seta on P4 enp-2 (instead of 1), the morphology of the fifth pair of legs which are not medially fused and have only 3 endopodal elements (instead of 4) in the male, and the well developed caudal ramus seta V (instead of rudimentary). It is postulated that prehensility of the P1 endopod was secondarily lost in the common ancestor of Paranaiara and Pseudocletodes. An updated family diagnosis of the Normanellidae and a dichotomous identification key to the 22 currently valid species are presented.
Resumo:
Introduction: TLR-4 has also been identified as a receptor for endogenous alarmins, which are increased post transplantation. TLR-4 has also been associated with a polymorphism that could impact graft outcome. Objective: To assess the expression of TLR-4 in kidney transplant patients carrying or not a polymorphism. Methods: TLR-4 polymorphism (A299G/T399I) was studied in 200 renal transplant patients. Healthy volunteers were also enrolled as control group. The polymorphism analysis was performed using restriction enzymes technique (RFLP). Functionality of TLR-4 polymorphism was assessed in samples from controls by quantification of TNF-alpha after LPS stimulus. TLR-4 and -2 expressions were also analyzed by flow cytometry. Results: TLR-4 polymorphism was present in 8.5% of renal transplant patients. This polymorphism was associated with impairment in TNF-alpha secretion. In general, in renal transplant patients, TLR-4 expression in monocytes and in neutrophils was lower than in health volunteers. TLR-2 and TLR-4 expressions in healthy volunteers with A299G/T399I TLR-4 polymorphism was higher than in wild-type genotype healthy volunteers (p<0.01 and p<0.05, respectively), and also higher than A299G/T399I TLR-4 polymorphism renal transplant patients (p<0.05). TLR-2 expression on neutrophils in wild-type genotype renal transplant patients was higher compared to wild-type genotype healthy volunteers, and was also higher in relation to A299G/T399I kidney transplanted patients (p<0.01). Conclusion: Stable renal transplant patients with TLR-4 polymorphism have a lower expression of TLR-4 and TLR-2 receptors in peripheral mononuclear cells, which ultimately indicate a less responsiveness for alarmins. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Introduction: Toll-like receptors (TLR) comprehend an emerging family of receptors that recognize pathogen-associated molecular patterns and promote the activation of leukocytes. Surgical trauma and ischemia-reperfusion injury are likely to provide exposure to endogenous ligands for TLR in virtually all kidney transplant recipients. Methods: Macroarray (GEArray OHS-018.2 Series-Superarray) analyses of 128 genes involved in TLR signaling pathway were performed in nephrectomy samples of patients with chronic allograft nephropathy (CAN) and acute rejection (AR, vascular and non vascular). The analysis of each membrane was performed by GEArray Expression Analysis Suite 2.0. Results: Macroarray profile identified a gene expression signature that could discriminate CAN and AR. Three genes were significantly expressed between CAN and vascular AR: Pellino 2; IL 8 and UBE2V1. In relation to vascular and non-vascular AR, there were only two genes with statistical significance: IL-6 and IRAK-3. Conclusion: Vascular and non-vascular AR and CAN showed different expression of a few genes in TLR pathway. The analysis of nephrectomy showed that activation of TLR pathway is present in AR and CAN. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Little is known about clinical differences associated with cytomegalovirus (CMV) infection by distinct strains in renal transplant patients. Different clinical pictures may be associated with specific viral genotypes. viral load, as well as host factors. The objective of this study was to identify CMV strains to determine viral load (antigenemia), and their correlation with clinical data in renal transplant recipients. Seventy-one patients were enrolled, comprising 91 samples. After selection, polymorphonuclear cells were used to amplify and sequence the gB region of CMV DNA. The sequences were analyzed to ascertain the frequency of different genotypes. Additionally, the results of this Study showed that the gB coding gene presents a great variability, revealing a variety of patterns: classical gB (1.4%), gB1V (46.4%), classical gB2 (35.2%), gB2V (2.8%), gB3 (1.4%), classical gB4 (4.9%) and gB4V (4.9%). The mean viral load in kidney transplant patient was 75.1 positive cells (1-1000). A higher viral load was observed in patients with genotype 4 infection. Statistically significant differences were detected between gB1 and gB4 (p=0.010), and between gB2 and gB4 (p=0.021). The average numbers of positive cells in relation to clinical presentation were: 34.5 in asymptomatic, 49.5 in CMV associated syndrome and 120.7 in patients with invasive disease (p=0.048). As a group, gB1 was the most frequent strain and revealed a potential risk for developing invasive disease. Viral load also seemed to be important as a marker associated with clinical presentation of the disease. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Objective: In previous studies cholesterol-rich nanoemulsions (LDE) resembling low-density lipoprotein were shown to concentrate in atherosclerotic lesions of rabbits. Lesions were pronouncedly reduced by treatment with paclitaxel associated with LDE. This study aimed to test the hypothesis of whether LDE-paclitaxel is able to concentrate in grafted hearts of rabbits and to ameliorate coronary allograft vasculopathy after the transplantation procedure. Methods: Twenty-one New Zealand rabbits fed 0.5% cholesterol were submitted to heterotopic heart transplantation at the cervical position. All rabbits undergoing transplantation were treated with cyclosporin A (10 mg . kg(-1) . d(-1) by mouth). Eleven rabbits were treated with LDE-paclitaxel (4 mg/kg body weight paclitaxel per week administered intravenously for 6 weeks), and 10 control rabbits were treated with 3 mL/wk intravenous saline. Four control animals were injected with LDE labeled with [(14)C]-cholesteryl oleate ether to determine tissue uptake. Results: Radioactive LDE uptake by grafts was 4-fold that of native hearts. In both groups the coronary arteries of native hearts showed no stenosis, but treatment with LDE-paclitaxel reduced the degree of stenosis in grafted hearts by 50%. The arterial luminal area in grafts of the treated group was 3-fold larger than in control animals. LDE-paclitaxel treatment resulted in a 7-fold reduction of macrophage infiltration. In grafted hearts LDE-paclitaxel treatment reduced the width of the intimal layer and inhibited the destruction of the medial layer. No toxicity was observed in rabbits receiving LDE-paclitaxel treatment. Conclusions: LDE-paclitaxel improved posttransplantation injury to the grafted heart. The novel therapeutic approach for heart transplantation management validated here is thus a promising strategy to be explored in future clinical studies. (J Thorac Cardiovasc Surg 2011;141:1522-8)
Resumo:
Introduction: This study prospectively accessed the immune response to the inactivated influenza vaccine in renal transplant recipients receiving either azathioprine or mycophenolate mofetil (MMF). Side effects were investigated. Methods: Sixty-nine patients received one dose of inactivated trivalent influenza vaccine. Antihemagglutinin (HI) antibody response against each strain was measured before and one to six months after vaccination. Results: Geometric mean HI antibody titers for H1N1 and H3N2 strains increased from 2.57 and 2.44 to 13.45 (p = 0.001) and 7.20 (p < 0.001), respectively. Pre- and post-vaccination protection rates for H1N1 and H3N2 increased from 8.7% to 49.3% (p < 0.001); and 36.3% (p < 0.001) and seroconversion rates were 36% and 25.3%, respectively. There was no response to influenza B. The use of MMF reduced the H1N1 and H3N2 protection rates and the seroconversion rate for the H1N1 strain when compared with the use of azathioprine, and subjects transplanted less than 87 months also had inferior antibody response. Adverse events were mild and there were no change on renal function post-vaccination. Conclusion: Renal transplant patients vaccinated against influenza responded with antibody production for in. uenza A virus strains, but not for in. uenza B. Use of MMF and shorter time from transplantation decreased the immune response to the vaccine.
Resumo:
Scanning electrochemical microscopy (SECM) in feedback mode was employed to characterise the reactivity and microscopic peculiarities of bismuth and bismuth/lead alloys plated onto gold disk substrates in 0.1 molL(-1) NaOH solutions. Methyl viologen was used as redox mediator, while a platinum microelectrode was employed as the SECM tip. The metal films were electrodeposited ex situ from NaOH solutions containing either bismuth ions only or both bismuth and lead ions. Approach curves and SECM images indicated that the metal films were conductive and locally reactive with oxygen to provide Bi(3+) and Pb(2+) ions. The occurrence of the latter chemical reactions was verified by local anodic stripping voltammetry (ASV) at the substrate solution interface by using a mercury-coated platinum SECM tip. The latter types of measurements allowed also verifying that lead was not uniformly distributed onto the bismuth film electrode substrate. These findings were confirmed by scanning electron microscopy images. The surface heterogeneity produced during the metal deposition process, however, did not affect the analytical performance of the bismuth coated gold electrode in anodic stripping voltammetry for the determination of lead in alkaline media, even in aerated aqueous solutions. Under the latter conditions, stripping peak currents proportional to lead concentration with a satisfactory reproducibility (within 5% RSD) were obtained.