2 resultados para standard error

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The aim of this study was to determine serum oxytocin concentrations following different regimens of prophylactic oxytocin administration in women undergoing elective caesarean delivery. Methods: Thirty healthy pregnant patients were randomized, after clamping of the umbilical cord, to receive intravenous oxytocin in one of the following groups: G1 (n = 9), 10 IU of oxytocin infused over 30 min (0.33 IU/min); G2 (n = 11), 10 IU of oxytocin infused over 3 min and 45 s (2.67 IU/min); and G3 (n = 10), 80 IU of oxytocin infused over 30 min (2.67 IU/min). Both patient and surgeon were blinded to allocation. Uterine tone was assessed by surgical palpation. Serum oxytocin concentration was determined by enzyme immunoassay before anaesthesia (T0) and at 5 (T5), 30 (T30) and 60 (T60) min after the start of oxytocin infusion. Results: Serum oxytocin concentrations (mean standard error, ng/mL) were not significantly different in the groups at T0 (0.06 +/- 0.02, 0.04 +/- 0.02 and 0.07 +/- 0.04, respectively, P = 0.76), and T60 (0.65 +/- 0.26, 0.36 +/- 0.26 and 0.69 +/- 0.26, respectively, P = 0.58). G3 showed higher concentrations than G1 at 15 (3.65 +/- 0.74 versus 0.71 +/- 0.27, P = 0.01) and at T30 (6.19 +/- 1.19 versus 1.17 +/- 0.37, P < 0.01), and were higher than G2 at T30 (6.19 +/- 1.19 versus 0.41 +/- 0.2, P < 0.01). Haemodynamic data and uterine tone were considered satisfactory and similar in all groups. No additional uterotonic agents were needed. Conclusion: Serum oxytocin measurements made using enzyme immunoassay in healthy pregnant women undergoing elective caesarean delivery showed that administration of 80 IU oxytocin over 30 min resulted in higher serum oxytocin levels after 5 and 30 min than the two other regimens. The concentrations did not differ between groups at 60 min. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We estimate the conditions for detectability of two planets in a 2/1 mean-motion resonance from radial velocity data, as a function of their masses, number of observations and the signal-to-noise ratio. Even for a data set of the order of 100 observations and standard deviations of the order of a few meters per second, we find that Jovian-size resonant planets are difficult to detect if the masses of the planets differ by a factor larger than similar to 4. This is consistent with the present population of real exosystems in the 2/1 commensurability, most of which have resonant pairs with similar minimum masses, and could indicate that many other resonant systems exist, but are currently beyond the detectability limit. Furthermore, we analyze the error distribution in masses and orbital elements of orbital fits from synthetic data sets for resonant planets in the 2/1 commensurability. For various mass ratios and number of data points we find that the eccentricity of the outer planet is systematically overestimated, although the inner planet`s eccentricity suffers a much smaller effect. If the initial conditions correspond to small-amplitude oscillations around stable apsidal corotation resonances, the amplitudes estimated from the orbital fits are biased toward larger amplitudes, in accordance to results found in real resonant extrasolar systems.