2 resultados para sotalol

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

High performance liquid chromatographic (HPLC) and UV derivative spectrophotometric (UVDS) methods were developed and validated for the quantitative determination of sotalol hydrochloride in tablets. The HPLC method was performed on a C18 column with fluorescence detection. The excitation and emission wavelengths were 235 and 310nm, respectively. The mobile phase was composed of acetonitrile-water containing 0.1% trietylamine (7:93v/v) and pH adjusted to 4.6 with formic acid. The UVDS method was performed taking a signal at 239.1nm in the first derivative. The correlation coefficients (r) obtained were 0.9998 and 0.9997 for HPLC and UVDS methods, respectively. The proposed methods are simple and adaptable to routine analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Extensive experimental studies and clinical evidence (Metabolic Efficiency with Ranzolazine for Less Ischemia in Non-ST-Elevation Acute Coronary Syndrome Thrombolysis in Myocardial Infarction-36 [MERLIN TIMI-36] trial) indicate potential antiarrhythmic efficacy of the antianginal agent ranolazine. Delivery of agents into the pericardial space allows high local concentrations to be maintained in close proximity to myocardial tissue while systemic effects are minimized. Methods and Results: The effects of intrapericardial (IPC) administration of ranolazine (50-mg bolus) on right atrial and right ventricular effective refractory periods (ERP), atrial fibrillation threshold, and ventricular fibrillation threshold were determined in 17 closed-chest anesthetized pigs. IPC ranolazine increased atrial ERP in a time-dependent manner from 129 +/- 5.14 to 186 +/- 9.78 ms (P < 0.01, N = 7) but did not significantly affect ventricular ERP (from 188.3 +/- 4.6 to 201 +/- 4.3 ms (NS, N = 6). IPC ranolazine increased atrial fibrillation threshold from 4.8 +/- 0.8 to 28 +/- 2.3 mA (P < 0.03, N = 6) and ventricular fibrillation threshold (from 24 +/- 3.56 baseline to 29.33 +/- 2.04 mA at 10-20 minutes, P < 0.03, N = 6). No significant change in mean arterial pressure was observed (from 92.8 +/- 7.1 to 74.8 +/- 7.5 mm Hg, P < 0.125, N = 5, at 7 minutes). Conclusions: IPC ranolazine exhibits striking atrial antiarrhythmic actions as evidenced by increases in refractoriness and in fibrillation inducibility without significantly altering mean arterial blood pressure. Ranolazine`s effects on the atria appear to be more potent than those on the ventricles.