8 resultados para sandstone reservoir

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Triggered seismicity is commonly associated with deep water reservoirs or injection wells where water is injected at high pressure into the reservoir rock. However, earth tremors related solely to the opening of groundwater wells are extremely rare. Here we present a clear case of seismicity induced by pore-pressure changes following the drilling of water wells that exploit a confined aquifer in the intracratonic Parana Basin of southeastern Brazil. Since 2004, shallow seismic activity, with magnitudes up to 2.9 and intensities V MM, has been observed near deep wells (120-200 m) that were drilled in early 2003 near the town of Bebedouro. The wells were drilled for irrigation purposes, cross a sandstone layer about 60-80 m thick and extract water from a confined aquifer in fractured zones between basalt flow layers. Seismic activity, mainly event swarms, has occurred yearly since 2004, mostly during the rainy season when the wells are not pumped. During the dry season when the wells are pumped almost continuously, the activity is very low. A seismographic network, installed in March 2005, has located more than 2000 microearthquakes. The events are less than 1 km deep (mostly within the 0.5 km thick basalt layer) and cover an area roughly 1.5 km x 5 km across. The seismicity generally starts in a small area and expands to larger distances with an equivalent hydraulic diffusivity ranging from 0.06 to 0.6 m(2)/s. Geophysical and geothermal logging of several wells in the area showed that water from the shallow sandstone aquifer enters the well at the top and usually forms waterfalls. The waterfalls flow down the sides of the wells and feed the confined, fractured aquifer in the basalt layer at the bottom. Two seismic areas are observed: the main area surrounds several wells that are pumped continuously during the dry season, and a second area near another well (about 10 km from the first area) that is not used for irrigation and not pumped regularly. The main area displays cyclic annual activity, but the second area does not. We explain the earthquake swarms as being triggered by pore pressure diffusion in the fractured basalt layer due to additional pressure from the newly connected surface aquifer. This reaches critically prestressed areas up to a few kilometers away from the wells. During periods of continuous pumping, the reduction of pore pressure in the confined aquifer stops the seismic activity. Our study suggests that this kind of activity may be more common than previously thought and implies that many other cases of small tremors associated with the drilling of water wells may have gone unnoticed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Castanhao reservoir was built in the state of Ceara, a dry region in Northeastern Brazil, to regulate the flow of the Jaguaribe River, for irrigation, and for power generation. It is an earth-filled dam, 60 m high, with a water capacity of 4.5 x 10(9) m(3). The seismicity in the area has been monitored since 1998, with a few interruptions, using one analog or one digital station and, during a few periods, a three-station network. The first earthquakes likely to be induced events were detected in 2003, when the water level was about 20 in high. In early 2004 a very heavy rainfall season quickly filled the reservoir. Shortly after, an increase in the seismic activity occurred and many micro-earthquakes were recorded. We suggest that this activity resulted from an increase in pore pressure due to undrained response. Therefore, we may classify this cluster of microearthquakes as ""initial seismicity."" We deployed a network with four analog stations in the area, following this activity, to determine the epicentral zone. At least three epicentral areas under the reservoir were detected. The spatio-temporal analysis of the available data revealed that the seismicity occurs in clusters and that these were activated at different periods. We identified four sets of faults (N-S-, E-W-, NW-SE-, and NE-SW-oriented), some of which moved in shallow crustal levels and as recently as the Quaternary (1.8 Ma). Under the present-day stress regime, the last two sets moved as strike-slip structures. We suggest a possible correlation between dormant faults and the observed induced seismicity. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background, aim and scope Although many recent studies have focused on sediment potential toxicity, few of them were performed in tropical shallow aquatic environments. Those places can suffer short-time variations, especially due to water column circulations generated by changes in temperature and wind. Rio Grande reservoir is such an example; aside from that, it suffers various anthropogenic impacts, despite its multiple uses. Materials and methods This work presents the first screening step for understanding sediment quality from Rio Grande reservoir by comparing metal content using three different sediment quality guidelines. We also aimed at verifying any possible spatial heterogeneity. Results and discussion We found spatial heterogeneity varying according to the specific metal. Results showed a tendency for metals to remain as insoluble as metal sulfide (potentially not bioavailable), since sulfide was in excess and sediment physical-chemical characteristics contribute to sulfide maintenance (low redox potential, neutral pH, low dissolved oxygen, and high organic matter content). On the other hand, metal concentrations were much higher than suggested by Canadian guidelines and regional background values, especially Cu, which raises the risk of metal remobilization in cases of water circulation. Further study steps include the temporal evaluation of AVS/SEM, a battery of bioassays and the characterization of organic compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Feces of 70 diarrhoeic and 230 non-diarrhoeic domestic cats from Sao Paulo, Brazil were investigated for enteropathogenic (EPEC), enterohaemorrhagic (EHEC) and enterotoxigenic (ETEC) Escherichia coli types. While ETEC and EHEC strains were not found, 15 EPEC strains were isolated from 14 cats, of which 13 were non-diarrhoeic, and one diarrhoeic. None of 15 EPEC strains carried the bfpA gene or the EPEC adherence factor plasmid, indicating atypical EPEC types. The EPEC strains were heterogeneous with regard to intimin types, such as eae-theta (three strains), eae-kappa (n = 3), eae-alpha 1 (n = 2), eae-iota (n = 2), one eae-alpha 2, eae-beta 1 and eae-eta each, and two were not typeable. The majority of the EPEC isolates adhered to HEp-2 cells in a localized adherence-like pattern and were positive for fluorescence actin staining. The EPEC strains belonged to 12 different serotypes, including O111:H25 and O125:H6, which are known to be pathogens in humans. Multi locus sequence typing revealed a close genetic similarity between the O111:H25 and O125:H6 strains from cats, dogs and humans. Our results show that domestic cats are colonized by EPEC, including serotypes previously described as human pathogens. As these EPEC strains are also isolated from humans, a cycle of mutual infection by EPEC between cats and its households cannot be ruled out, though the transmission dynamics among the reservoirs are not yet understood clearly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we demonstrate that the inevitable action of the environment can be substantially weakened when considering appropriate nonstationary quantum systems. Beyond protecting quantum states against decoherence, an oscillating frequency can be engineered to make the system-reservoir coupling almost negligible. Differently from the program for engineering reservoir and similarly to the schemes for dynamical decoupling of open quantum systems, our technique does not require previous knowledge of the state to be protected. However, differently from the previously-reported schemes for dynamical decoupling, our technique does not rely on the availability of tailored external pulses acting faster than the shortest timescale accessible to the reservoir degree of freedom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we analyze the double Caldeira-Leggett model: the path integral approach to two interacting dissipative harmonic oscillators. Assuming a general form of the interaction between the oscillators, we consider two different situations: (i) when each oscillator is coupled to its own reservoir, and (ii) when both oscillators are coupled to a common reservoir. After deriving and solving the master equation for each case, we analyze the decoherence process of particular entanglements in the positional space of both oscillators. To analyze the decoherence mechanism we have derived a general decay function, for the off-diagonal peaks of the density matrix, which applies both to common and separate reservoirs. We have also identified the expected interaction between the two dissipative oscillators induced by their common reservoir. Such a reservoir-induced interaction, which gives rise to interesting collective damping effects, such as the emergence of relaxation- and decoherence-free subspaces, is shown to be blurred by the high-temperature regime considered in this study. However, we find that different interactions between the dissipative oscillators, described by rotating or counter-rotating terms, result in different decay rates for the interference terms of the density matrix. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anomalous concentrations of Cr(VI) occur in groundwaters of the Adamantina Aquifer, in a large region in the western state of Sao Paulo, sometimes exceeding the potability limit (0.05 mg L(-1)). To identify the possible geochemical reactions responsible for the occurrence of Cr in groundwater in Urania, borehole rock samples were collected in order to carry out mineralogical and chemical analyses. In addition, multilevel monitoring wells were installed and groundwater samples were analyzed. Analyses of the borehole rock samples show the occurrence of a geochemical anomaly of Cr in the quartzose sandstones (average concentrations of 221 ppm). Chrome-diopside is one of the main minerals contributing to this anomaly, having an average Cr content of 1505 ppm. Sequential extraction experiments indicated weakly adsorbed Cr in the order of 0.54 ppm, and this quantity is enough to provide the Cr concentrations observed in groundwater. Groundwaters from the monitoring wells proved to be stratified, with the highest concentrations of Cr(VI) (0.13 mg L(-1)) being associated with high redox and pH values (over 10) and high concentrations of Na. Geochemical reactions that may explain the release of Cr from the solid phase to groundwater involve the release of Cr(III) from minerals (like chrome-diopside and Cr-Fe hydroxide), followed by oxidation of Cr(III) to Cr(VI), probably related to the reduction of Mn oxides present in the aquifer. Then cation exchange occurs and dissolution of carbonates which increases the pH of groundwater, resulting in the desorption and mobilization of Cr(VI) into groundwater. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anomalous and natural concentrations of Cr(6+), occasionally exceeding the permitted limit for human consumption (0.05 mg/L), have been detected in groundwater in the northwestern region of the state of Sao Paulo. As part of a water-rock interaction investigation, this article describes the chemical and mineralogical characterization of rock samples taken from boreholes in the municipality of Urania, with the objective of identifying Cr-bearing minerals and determining how chromium is associated with these minerals. Rock sample analysis were performed using X-ray Fluorescence, X-ray Diffraction, Scanning Electron Microscopy, electron microprobe and sequential extraction techniques. Chemical analyses indicated that the quartzose sandstones show a geochemical anomaly of chromium, with an average content of 221 ppm, which is higher than the reported chromium content of generic sandstones (35 ppm). Diopside was identified as the primary Cr-bearing mineral potentially subject to weathering processes, with a chromium content of up to 1.2% as Cr(2)O(3). Many of the diopside grains showed dissolution features, confirming the occurrence of weathering. Sequential extraction experiments indicated that 99.3% of the chromium in samples is tightly bonded to minerals, whereas 0.24% is weakly bonded via adsorption. Assuming hypothetically that all adsorbed chromium is released via desorption, the theoretical Cr concentration in water would be one order of magnitude higher than the concentrations of Cr(6+) detected in groundwater. (C) 2010 Elsevier Ltd. All rights reserved.