60 resultados para projection welding
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
The aim of this study was to analyze the shear bond strength between commercially pure titanium, with and without laser welding, after airbone-particle abrasion (Al2O3) and 2 indirect composites. Sixty-four specimens were cast and divided into 2 groups with and without laser welding. Each group was divided in 4 subgroups, related to Al2O3 grain size: A - 250 µm; B - 180 µm; C- 110 µm; and D - 50 µm. Composite rings were formed around the rods and light polymerized using UniXS unit. Specimens were invested and their shear bond strength at failure was measured with a universal testing machine at a crosshead speed of 2.0 mm/min. Statistical analysis was carried out with ANOVA and Tukey's test (α=0.05). The highest bond strength means were recorded in 250 µm group without laser welding. The lowest shear bond strength means were recorded in 50 µm group with laser welding. Statistically significant differences (p<0.05) were found between all groups. In conclusion, airborne particle abrasion yielded significantly lower bond strength as the Al2O3 particle size decreased. Shear bond strength decreased in the laser welded specimens.
Resumo:
The ability to control both the minimum size of holes and the minimum size of structural members are essential requirements in the topology optimization design process for manufacturing. This paper addresses both requirements by means of a unified approach involving mesh-independent projection techniques. An inverse projection is developed to control the minimum hole size while a standard direct projection scheme is used to control the minimum length of structural members. In addition, a heuristic scheme combining both contrasting requirements simultaneously is discussed. Two topology optimization implementations are contributed: one in which the projection (either inverse or direct) is used at each iteration; and the other in which a two-phase scheme is explored. In the first phase, the compliance minimization is carried out without any projection until convergence. In the second phase, the chosen projection scheme is applied iteratively until a solution is obtained while satisfying either the minimum member size or minimum hole size. Examples demonstrate the various features of the projection-based techniques presented.
Distributed Estimation Over an Adaptive Incremental Network Based on the Affine Projection Algorithm
Resumo:
We study the problem of distributed estimation based on the affine projection algorithm (APA), which is developed from Newton`s method for minimizing a cost function. The proposed solution is formulated to ameliorate the limited convergence properties of least-mean-square (LMS) type distributed adaptive filters with colored inputs. The analysis of transient and steady-state performances at each individual node within the network is developed by using a weighted spatial-temporal energy conservation relation and confirmed by computer simulations. The simulation results also verify that the proposed algorithm provides not only a faster convergence rate but also an improved steady-state performance as compared to an LMS-based scheme. In addition, the new approach attains an acceptable misadjustment performance with lower computational and memory cost, provided the number of regressor vectors and filter length parameters are appropriately chosen, as compared to a distributed recursive-least-squares (RLS) based method.
Resumo:
Recent advances in the control of molecular engineering architectures have allowed unprecedented ability of molecular recognition in biosensing, with a promising impact for clinical diagnosis and environment control. The availability of large amounts of data from electrical, optical, or electrochemical measurements requires, however, sophisticated data treatment in order to optimize sensing performance. In this study, we show how an information visualization system based on projections, referred to as Projection Explorer (PEx), can be used to achieve high performance for biosensors made with nanostructured films containing immobilized antigens. As a proof of concept, various visualizations were obtained with impedance spectroscopy data from an array of sensors whose electrical response could be specific toward a given antibody (analyte) owing to molecular recognition processes. In addition to discussing the distinct methods for projection and normalization of the data, we demonstrate that an excellent distinction can be made between real samples tested positive for Chagas disease and Leishmaniasis, which could not be achieved with conventional statistical methods. Such high performance probably arose from the possibility of treating the data in the whole frequency range. Through a systematic analysis, it was inferred that Sammon`s mapping with standardization to normalize the data gives the best results, where distinction could be made of blood serum samples containing 10(-7) mg/mL of the antibody. The method inherent in PEx and the procedures for analyzing the impedance data are entirely generic and can be extended to optimize any type of sensor or biosensor.
Resumo:
Purpose: The aim of this study was to compare the accuracy of fit of three types of implant-supported frameworks cast in Ni-Cr alloy: specifically, a framework cast as one piece compared to frameworks cast separately in sections to the transverse or the diagonal axis, and later laser welded. Materials and Methods: Three sets of similar implant-supported frameworks were constructed. The first group of six 3-unit implant-supported frameworks were cast as one piece, the second group of six were sectioned in the transverse axis of the pontic region prior to casting, and the last group of six were sectioned in the diagonal axis of the pontic region prior to casting. The sectioned frameworks were positioned in the matrix (10 N(.)cm torque) and laser welded. To evaluate passive fit, readings were made with an optical microscope with both screws tightened and with only one-screw tightened. Data were submitted to ANOVA and Tukey-Kramer`s test (p < 0.05). Results: When both screws were tightened, no differences were found between the three groups (p > 0.05). In the single-screw-tightened test, with readings made opposite to the tightened side, the group cast as one piece (57.02 +/- 33.48 mu m) was significantly different (p < 0.05) from the group sectioned diagonally (18.92 +/- 4.75 mu m) but no different (p > 0.05) from the group transversally sectioned (31.42 +/- 20.68 mu m). On the tightened side, no significant differences were found between the groups (p > 0.05). Conclusions: Results of this study showed that casting diagonally sectioned frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves the levels of passivity to the same frameworks when compared to structures cast as one piece.
Resumo:
This study compared the vertical misfit of 3-unit implant-supported nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloy and commercially pure titanium (cpTi) frameworks after casting as 1 piece, after sectioning and laser welding, and after simulated porcelain firings. The results on the tightened side showed no statistically significant differences. On the opposite side, statistically significant differences were found for Co-Cr alloy (118.64 mu m [SD: 91.48] to 39.90 mu m [SD: 27.13]) and cpTi (118.56 mu m [51.35] to 27.87 mu m [12.71]) when comparing 1-piece to laser-welded frameworks. With both sides tightened, only Co-Cr alloy showed statistically significant differences after laser welding. Ni-Cr alloy showed the lowest misfit values, though the differences were not statistically significantly different. Simulated porcelain firings revealed no significant differences.
Resumo:
P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58 center dot 66 +/- 14 center dot 30 mu m) was significantly different from cp Ti group after diagonal section (IV: 27 center dot 51 +/- 8 center dot 28 mu m) (P < 0 center dot 05). On the tightened side, no significant differences were found between groups (P > 0 center dot 05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.
Resumo:
The problem of projecting multidimensional data into lower dimensions has been pursued by many researchers due to its potential application to data analyses of various kinds. This paper presents a novel multidimensional projection technique based on least square approximations. The approximations compute the coordinates of a set of projected points based on the coordinates of a reduced number of control points with defined geometry. We name the technique Least Square Projections ( LSP). From an initial projection of the control points, LSP defines the positioning of their neighboring points through a numerical solution that aims at preserving a similarity relationship between the points given by a metric in mD. In order to perform the projection, a small number of distance calculations are necessary, and no repositioning of the points is required to obtain a final solution with satisfactory precision. The results show the capability of the technique to form groups of points by degree of similarity in 2D. We illustrate that capability through its application to mapping collections of textual documents from varied sources, a strategic yet difficult application. LSP is faster and more accurate than other existing high-quality methods, particularly where it was mostly tested, that is, for mapping text sets.
Resumo:
We report vibrational excitation (v(i) = 0 -> v(f) = 1) cross-sections for positron scattering by H(2) and model calculations for the (v(i) = 0 -> v(f) = 1) excitation of the C-C symmetric stretch mode of C(2)H(2). The Feshbach projection operator formalism was employed to vibrationally resolve the fixed-nuclei phase shifts obtained with the Schwinger multichannel method. The near threshold behavior of H(2) and C(2)H(2) significantly differ in the sense that no low lying singularity (either virtual or bound state) was found for the former, while a e(+)-acetylene virtual state was found at the equilibrium geometry (this virtual state becomes a bound state upon stretching the molecule). For C(2)H(2), we also performed model calculations comparing excitation cross-sections arising from virtual (-i kappa(0)) and bound (+i kappa(0)) states symmetrically located around the origin of the complex momentum plane (i.e. having the same kappa(0)). The virtual state is seen to significantly couple to vibrations, and similar cross-sections were obtained for shallow bound and virtual states. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
TEMA: a produção da fala nas modalidades de reabilitação oral protética. OBJETIVO: verificar se o tipo de reabilitação oral interfere na produção da fala. MÉTODO: 36 idosos (média = 68 anos), divididos em 3 grupos, foram avaliados: 13 com dentes naturais (A), 13 com prótese total mucosossuportada superior e inferior (B) e 10 com prótese total mucosossuportada superior e implantossuportada inferior (C). A estabilidade das próteses foi avaliada por um dentista e amostras de fala foram analisadas por 5 fonoaudiólogos. Para determinar a freqüência de alteração dos sons da fala utilizou-se o cálculo da Porcentagem de Consoantes Corretas (PCC). RESULTADOS: observou-se poucos casos com alteração de fala, com maior freqüência no grupo C (23,08%), sendo a articulação travada presente em todos os grupos, a redução dos movimentos labiais em dois grupos (A e B) e a articulação exagerada e a falta de controle salivar em um dos grupos (C e B). Quanto à PCC, menor valor foi observado para os fones linguodentais nos grupos B e C (maior ocorrência de alteração), seguido dos fones alveolares, predominando casos sem alteração no grupo A, contrariamente aos demais grupos, sendo a projeção lingual e o ceceio as alterações mais encontradas. Não houve diferença entre os grupos e a maioria do grupo B estava com a prótese inferior insatisfatória, não havendo associação entre alteração de fala e prótese insatisfatória. CONCLUSÃO: apesar da amostra pequena, indivíduos reabilitados com prótese total apresentam alteração nos fones linguodentais e alveolares e o tipo de prótese, bem como a estabilidade desta parece não interferir na produção da fala.
Resumo:
PURPOSE: To analyze the effects of detachment and repositioning of the medial pterygoid muscle on the growth of the maxilla and mandible of young rats through cephalometry. METHODS: Thirty one-month-old Wistar rats were used, distributed into three groups: experimental, sham-operated and control. In the experimental group, unilateral detachment and repositioning of the medial pterygoid muscle was performed. The sham-operated group only underwent surgical access, and the control group did not undergo any procedure. The animals were sacrificed at the age of three months. Their soft tissues were removed and the mandible was disarticulated. Radiographs of the skull in axial projection and the hemimandibles in lateral projection were obtained, and cephalometry was performed. The values obtained were subjected to statistical analyses among the groups and between the sides in each group. RESULTS: There were significant differences in the length of the mandible relative to the angular process in the experimental group and in the height of the mandibular body in the sham-operated group. CONCLUSION: The experimental detachment and repositioning of the medial pterygoid muscle during the growth period in rats affected the growth of the angle region, resulting in asymmetry of the mandible.
Resumo:
OBJETIVO: avaliar a influência da idade, do sexo, da relação oclusal sagital, do Padrão Facial e de 8 medidas do perfil facial sobre a estética do perfil. MÉTODOS: foram utilizadas tabelas de contingência, o Teste Qui-quadrado e o coeficiente de Cramér para avaliar a possível associação entre a nota dada por 32 avaliadores (14 ortodontistas, 12 leigos e 6 artistas) para a estética do perfil de 100 brasileiros - adultos, leucodermas, portadores de selamento labial passivo - e a idade, o sexo, a relação oclusal sagital, o Padrão Facial e as variáveis da análise facial numérica do perfil. RESULTADOS: não foi observada associação entre a idade, o sexo e a relação oclusal sagital e a estética do perfil facial. A associação foi observada entre a nota recebida para a estética do perfil e o Padrão Facial, o ângulo de convexidade facial e o ângulo do terço inferior da face. CONCLUSÃO: o Padrão Facial, definido na avaliação do perfil pela convexidade do perfil facial, e a projeção anterior do mento foram, entre os fatores avaliados, os determinantes para a estética do perfil facial.
Resumo:
Ituglanis mambai, new species, is described from a cave in the Mambaí karst area, State of Goiás, Central Brazil. The new species distinguishes from epigean and cave congeners by the combination of the following characteristics: posterior supraoccipital fontanel absent; pectoral-fin rays usually i,7; six pleural ribs; total vertebrae 37-38 behind Weberian apparatus; shorter predorsal length (65.1-70.8% SL); shorter caudal peduncle length (8.4-11.9% SL); shorter dorsal-fin base length (7.7-11.3% SL); wider interobital width (29.2-36.5% HL); larger mouth width (43.4-64.0% HL); intermediate between epigean and other cave Ituglanis species as regards to both eyes (diameter varying from 0.5 to1.0 mm in adults, 7.8-10.1 % HL) and pigmentation, composed by irregular light brown spots along the body. The latter indicate the troglobitic status for I. mambai. In addition, this species has the maxillae with a discrete medial-posterior projection; fronto-lacrimal one half-length of the maxillae and pointed backwards; posterior process of palatine half its length, with a tenuous medial concavity; 14 dorsal and 12 ventral procurrent rays. In the natural habitat, I. mambai displayed cryptobiotic habits, trying to hide in the graveled bottom or under boulders when disturbed, apparently showing a negative response to light. It was observed a preference to slow-moving waters. Recent flood marks were observed in the stream conduit in March/April 2007 (end of the rainy season) when less individuals were observed on 300 m of the subterranean stream compared to September 2004 (end of the dry season).
Resumo:
This article describes the use of a projection spectrograph based on an overhead projector for use in classroom demonstrations on light polarization and optical activity. A simple adaptation on a previously developed apparatus allows illustrating several aspects of optical activity, such as circular and linear birefringence, including their wavelength dependence. Specifically, we use the projection spectrograph to demonstrate the optical activity of an aqueous solution of sugar (circular birefringence), of a quartz plate and of an overhead projector transparence film (linear birefringence). A historical survey about the optical activity discovery and the main principles involved is also presented.
Resumo:
This article describes a projection spectrograph for use in optical spectroscopy classrooms demonstrations. The apparatus is based on an overhead projector and permits the visualization of several phenomena such as, light dispersion by diffraction gratings, diffraction order, optical fluorescence, continuous and discrete optical emission spectra, and light absorption by liquids and solids. A historical survey about the optical spectroscopy development is also presented.