2 resultados para monobloco
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100%) given to abutment screws. Pearson's correlation (α=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37%) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.
Resumo:
The aim of this study was to evaluate the efficacy of a cost-effective intra-oral appliance for obstructive sleep apnea syndrome built into a large teaching hospital. Out of 20 evaluated and treated patients, 14 concluded the study: eight men and six women, with a mean age of 42-46 (mean + SD) years and mean body mass index of 27.66. Inclusion criteria were mild or moderate apnea-hypopnea index (AHI) according to a polysomnographic study. All patients were treated with the monobloco intra-oral appliance. They were then submitted to a follow-up polysomnographic study after 60 days using the appliance. An orofacial clinical evaluation was carried out with the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) questionnaire and with clinical evaluation questionnaire devised by the Orofacial Pain Team before and 60 days after fitting the intra-oral appliance. The AHI showed a statistically meaningful (p = 0.002) reduction from 15.53 to 7.82 events per hour, a non-statistically significant oxygen saturation increase from 83.36 to 84.86 (p = 0.09), and Epworth`s sleepiness scale reduction from 9.14 to 6.36 (p = 0.001). Three patients did not show any improvement. The most common side effect during the use of the appliance/device was pain and facial discomfort (28.57%), without myofascial or temporomandibular joint pain as evaluated by the RDC/TMD questionnaire. The intra-oral device produced a significant reduction of the apnea-hypopnea index during the study period with the use of the monobloco intra-oral appliance. Patients did not show prior myofascial pain or 60 days after use of the intra-oral appliance.