13 resultados para measurement of microvibration
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Background: Oxidative modification of low-density lipoprotein (LDL) plays a key role in the pathogenesis of atherosclerosis. LDL(-) is present in blood plasma of healthy subjects and at higher concentrations in diseases with high cardiovascular risk, such as familial hypercholesterolemia or diabetes. Methods: We developed and validated a sandwich ELISA for LDL(-) in human plasma using two monoclonal antibodies against LDL(-) that do not bind to native LDL, extensively copper-oxidized LDL or malondialdehyde-modified LDL. The characteristics of assay performance, such as limits of detection and quantification, accuracy, inter- and intra-assay precision were evaluated. The linearity, interferences and stability tests were also performed. Results: The calibration range of the assay is 0.625-20.0 mU/L at 1: 2000 sample dilution. ELISA validation showed intra- and inter- assay precision and recovery within the required limits for immunoassays. The limits of detection and quantification were 0.423 mU/L and 0.517 mU/L LDL(-), respectively. The intra- and inter- assay coefficient of variation ranged from 9.5% to 11.5% and from 11.3% to 18.9%, respectively. Recovery of LDL(-) ranged from 92.8% to 105.1%. Conclusions: This ELISA represents a very practical tool for measuring LDL(-) in human blood for widespread research and clinical sample use. Clin Chem Lab Med 2008; 46: 1769-75.
Resumo:
A new method to measure the epicycle frequency kappa in the Galactic disc is presented. We make use of the large data base on open clusters completed by our group to derive the observed velocity vector (amplitude and direction) of the clusters in the Galactic plane. In the epicycle approximation, this velocity is equal to the circular velocity given by the rotation curve, plus a residual or perturbation velocity, of which the direction rotates as a function of time with the frequency kappa. Due to the non-random direction of the perturbation velocity at the birth time of the clusters, a plot of the present-day direction angle of this velocity as a function of the age of the clusters reveals systematic trends from which the epicycle frequency can be obtained. Our analysis considers that the Galactic potential is mainly axis-symmetric, or in other words, that the effect of the spiral arms on the Galactic orbits is small; in this sense, our results do not depend on any specific model of the spiral structure. The values of kappa that we obtain provide constraints on the rotation velocity of the in particular, V(0) is found to be 230 +/- 15 km s(-1) even if the scale (R(0) = 7.5 kpc) of the Galaxy is adopted. The measured kappa at the solar radius is 43 +/- 5 km s(-1) kpc(-1). The distribution of initial velocities of open clusters is discussed.
Resumo:
The ground state thermal neutron cross section and the resonance integral for the (165)Ho(n, gamma)(166)Ho reaction in thermal and 1/E regions, respectively, of a thermal reactor neutron spectrum have been measured experimentally by activation technique. The reaction product, (166)Ho in the ground state, is gaining considerable importance as a therapeutic radionuclide and precisely measured data of the reaction are of significance from the fundamental point of view as well as for application. In this work, the spectrographically pure holmium oxide (Ho(2)O(3)) powder samples were irradiated with and without cadmium covers at the IEA-RI reactor (IPEN, Sao Paulo), Brazil. The deviation of the neutron spectrum shape from 1/E law was measured by co-irradiating Co, Zn, Zr and Au activation detectors with thermal and epithermal neutrons followed by regression and iterative procedures. The magnitudes of the discrepancies that can occur in measurements made with the ideal 1/E law considerations in the epithermal range were studied. The measured thermal neutron cross section at the Maxwellian averaged thermal energy of 0.0253 eV is 59.0 +/- 2.1 b and for the resonance integral 657 +/- 36b. The results are measured with good precision and indicated a consistency trend to resolve the discrepant status of the literature data. The results are compared with the values in main libraries such as ENDF/B-VII, JEF-2.2 and JENDL-3.2, and with other measurements in the literature.
Resumo:
We report the first observation of two Cabibbo-suppressed ecay modes, Xi(+)(c) -> Sigma(+)pi(-)pi(+) and Xi c+ -> Sigma(-)pi(+)pi(+). We observe 59 +/- 14 over a background of 87, and 22 +/- 8 over a background of 13 events, respectively, for the signals. The data were accumulated using the SELEX spectrometer during the 1996-1997 fixed target run at Fermilab, chiefly from a 600 Gev/c Sigma(-) beam. The branching ratios of the decays relative to the Cabibbo-favored Xi c+ -> Xi(-)pi(+)pi(+) are measured to be B(Xi(+)(c) -> Sigma(+)pi(-)pi(+))/B(Xi(+)(c) -> Xi(-)pi(+)pi(+)) = 0.48 +/- 0.20, and B(Xi(+)(c) -> Sigma(-)pi(+)pi(+))/B(Xi(+)(c) -> Sigma(-)pi(+)pi(+)) = 0.18 +/- 0.09, respectively. We also report branching ratios for the same decay modes of the Delta(+)(c) relative to Delta(+)(c) -> pK(-)pi(+.) (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
The (16)O+(27)Al elastic and inelastic angular distributions have been measured in a broad angular range (13 degrees < theta(lab) < 52 degrees) at about 100 MeV incident energy. The use of the MAGNEX large acceptance magnetic spectrometer and of the ray-reconstruction analysis technique has been crucial in order to provide, in the same experiment, high-resolution energy spectra and cross-section measurements distributed over more than seven orders of magnitude down to hundreds of nb/sr. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
We describe how the method of detection of delayed K x-rays produced by the electron capture decay of the residual nuclei can be a powerful tool in the investigation of the effect of the breakup process on the complete fusion (CF) cross-section of weakly bound nuclei at energies close to the Coulomb barrier. This is presently one of the most interesting subjects under investigation in the field of low-energy nuclear reactions, and the difficult experimental task of separating CF from the incomplete fusion (ICF) of one of the breakup fragments can be achieved by the x-ray spectrometry method. We present results for the fusion of the (9)Be + (144)Sm system. Copyright (c) 2008 John Wiley & Sons, Ltd.
Resumo:
Electron transport parameters are important in several areas ranging from particle detectors to plasma-assisted processing reactors. Nevertheless, especially at high fields strengths and for complex gases, relatively few data are published. A dedicated setup has been developed to measure the electron drift velocity and the first Townsend coefficient in parallel plate geometry. An RPC-like cell has been adopted to reach high field strengths without the risk of destructive sparks. The validation data obtained with pure Nitrogen will be presented and compared to a selection of the available literature and to calculations performed with Magboltz 2 version 8.6. The new data collected in pure Isobutane will then be discussed. This is the first time the electron drift velocity in pure Isobutane is measured well into the saturation region. Good agreement is found with expectations from Magboltz. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
We report the J/psi -> e(+)e(-) and the psi` -> e(+)e(-) production cross sections in the PHENIX experiment at RHIC. The first measurements of the production cross sections of the psi` and the psi` over the J/psi, will contribute to the clarification of the theoretical understanding of the J/psi meson production. The inclusive J/psi polarization through the same decay channel is also presented, showing a trend of slightly longitudinal polarization for p(T) <5 GeV/c.
Resumo:
The aim of this study was to evaluate the shrinkage of a microhybrid dental composite resin photo-activated by one LED with different power densities by means of speckle technique. The dental composite resin Filtek (TM) Z-250 (3M/ESPE) at color A(2) was used for the samples preparation. Uncured composite was packed in a metallic mold and irradiated during 20 s from 100 to 1000 mW cm(-2). For the photo-activation of the samples, it was used a LED prototype (Light Emission Diode) with wavelength centered at 470 nm and adjustable power density until 1 W cm(-2). The speckle patterns obtained from the bottom composite surfaces were monitored using a CCD camera without lens. The speckle field is recorded in a digital picture and stored by CCD camera as the carrier of information on the displacement of the tested surface. The calculated values were obtained for each pair of adjacent patterns and the changes in speckle contrast as a function of time were obtained from six repeated measurements. The speckle contrasts obtained from the bottom surface with 100 mW cm(-1) were smaller than those than the other power densities. The higher power densities provided the higher shrinkage.
Resumo:
In this paper, I review some recent high-precision Rydberg state lifetime measurements using a cold-trapped sample of neutral atoms held in a magneto-optical trap. The measurements were performed in rubidium for the S, P and D states varying the principal quantum number from n = 26 to 45 using the field ionization technique. The experimental results were compared with quantum mechanical calculations and good agreement was observed. This is an important demonstration of how cold atomic samples can be used to perform high-precision spectroscopy in the time domain.
Measurement of the energy spectrum of cosmic rays above 10(18) eV using the Pierre Auger Observatory
Resumo:
We report a measurement of the flux of cosmic rays with unprecedented precision and Statistics using the Pierre Auger Observatory Based on fluorescence observations in coincidence with at least one Surface detector we derive a spectrum for energies above 10(18) eV We also update the previously published energy spectrum obtained with the surface detector array The two spectra are combined addressing the systematic uncertainties and, in particular. the influence of the energy resolution on the spectral shape The spectrum can be described by a broken power law E(-gamma) with index gamma = 3 3 below the ankle which is measured at log(10)(E(ankle)/eV) = 18 6 Above the ankle the spectrum is described by a power law with index 2 6 followed by a flux suppression, above about log(10)(E/eV) = 19 5, detected with high statistical significance (C) 2010 Elsevier B V All rights reserved
Resumo:
Objectives: Studies of the viscoelastic properties of the vocal folds are normally performed with rheometers that use parallel assigned a fixed value. In tissues subject to variation of thickness plates whose interplate space is usually at between samples, fixed gaps could result in different compressions, compromising the comparison among them. We performed,in experimental study to determine whether different compressions call lead to different results in measurements of dynamic viscosity (DV) of vocal fold samples. Methods: We Measured the DV of vocal fold samples of 10 larynges of cadavers under 3 different compression levels, corresponding to 0.2, 0.5, and 10 N on an 8-mm-diameter parallel-plate rheometer. Results: The DV directly varied with compression. We observed statistically significant differences between the results of 0.2 and 10 N (p = 0.0396) and 0.5 and 10 N (p = 0.0442). Conclusions: The study demonstrated that the level of compression influences the DV measure and Suggests that a defined compression level should be used in rheometric studies of biological tissues.
Resumo:
The electroanalytical techniques are very promissing to perform the quality control of crude vegetable. Solid State Differential Pulse Voltammetry in the supporting electrolyte is able to detect the oxidation signals of the active material, which can be used as a parameter to identify the type of crude vegetable and its antioxidant activity. The working electrode consisted in a carbon paste electrode modified with the powder of vegetable raw material (EMF). The electrochemical measurements were performed in a cell containing the working (EMF), reference (Ag/AgCl, KClsat) and auxiliary (Pt) electrodes.