82 resultados para intraaortic balloon pump
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Flow pumps are important tools in several engineering areas, such as in the fields of bioengineering and thermal management solutions for electronic devices. Nowadays, many of the new flow pump principles are based on the use of piezoelectric actuators, which present some advantages such as miniaturization potential and lower noise generation. In previous work, authors presented a study of a novel pump configuration based on placing an oscillating bimorph piezoelectric actuator in water to generate flow. It was concluded that this oscillatory behavior (such as fish swimming) yields vortex interaction, generating flow rate due to the action and reaction principle. Thus, following this idea the objective of this work is to explore this oscillatory principle by studying the interaction among generated vortex from two bimorph piezoelectric actuators oscillating inside the same pump channel, which is similar to the interaction of vortex generated by frontal fish and posterior ones when they swim together in a group formation. It is shown that parallel-series configurations of bimorph piezoelectric actuators inside the same pump channel provide higher flow rates and pressure for liquid pumping than simple parallel-series arrangements of corresponding single piezoelectric pumps, respectively. The scope of this work includes structural simulations of bimorph piezoelectric actuators, fluid flow simulations, and prototype construction for result validation.
Resumo:
Flow pumps have been developed for classical applications in Engineering, and are important instruments in areas such as Biology and Medicine. Among applications for this kind of device we notice blood pump and chemical reagents dosage in Bioengineering. Furthermore, they have recently emerged as a viable thermal management solution for cooling applications in small-scale electronic devices. This work presents the performance study of a novel principle of a piezoelectric flow pump which is based oil the use of a bimorph piezoelectric actuator inserted in fluid (water). Piezoelectric actuators have some advantages over classical devices, such as lower noise generation and ease of miniaturization. The main objective is the characterization of this piezoelectric pump principle through computational simulations (using finite element software), and experimental tests through a manufactured prototype. Computational data, Such as flow rate and pressure curves, have also been compared with experimental results for validation purposes. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
In the development of a ventricular assist device, computational fluid dynamics (CFD) analysis is an efficient tool to obtain the best design before making the final prototype. In this study, different designs of a centrifugal blood pump were developed to investigate flow characteristics and performance. This study assumed the blood flow as being an incompressible homogeneous Newtonian fluid. A constant velocity was applied at the inlet; no slip boundary conditions were applied at device wall; and pressure boundary conditions were applied at the outlet. The CFD code used in this work was based on the finite volume method. In the future, the results of CFD analysis can be compared with flow visualization and hemolysis tests.
Resumo:
This article presents a back-electromotive force (BEMF)-based technique of detection for sensorless brushless direct current motor (BLDCM) drivers. The BLDCM has been chosen as the energy converter in rotary or pulsatile blood pumps that use electrical motors for pumping. However, in order to operate properly, the BLDCM driver needs to know the shaft position. Usually, that information is obtained through a set of Hall sensors assembled close to the rotor and connected to the electronic controller by wires. Sometimes, a large distance between the motor and controller makes the system susceptible to interference on the sensor signal because of winding current switching. Thus, the goal of the sensorless technique presented in this study is to avoid this problem. First, the operation of BLDCM was evaluated on the electronic simulator PSpice. Then, a BEMF detector circuitry was assembled in our laboratories. For the tests, a sensor-dependent system was assembled where the direct comparison between the Hall sensors signals and the detected signals was performed. The obtained results showed that the output sensorless detector signals are very similar to the Hall signals at speeds of more than 2500 rpm. Therefore, the sensorless technique is recommended as a responsible or redundant system to be used in rotary blood pumps.
Resumo:
BACKGROUND AND PURPOSE The consequences of compensatory responses to balloon catheter injury in rat carotid artery, on phenylephrine-induced relaxation and contraction in the contralateral carotid artery were studied. EXPERIMENTAL APPROACH Relaxation and contraction concentration-response curves for phenylephrine were obtained for contralateral carotid arteries in the presence of indomethacin (COX inhibitor), SC560 (COX-1 inhibitor), SC236 (COX-2 inhibitor) or 4-hydroxytetramethyl-L-piperidine-1-oxyl (tempol; superoxide dismutase mimetic). Reactive oxygen species were measured in carotid artery endothelial cells fluorimetrically with dihydroethidium. KEY RESULTS Phenylephrine-induced relaxation was abolished in contralateral carotid arteries from operated rats (E(max) = 0.01 +/- 0.004 g) in relation to control (E(max) = 0.18 +/- 0.005 g). Phenylephrine-induced contractions were increased in contralateral arteries (E(max) = 0.54 +/- 0.009 g) in relation to control (E(max) = 0.38 +/- 0.014 g). SC236 restored phenylephrine-induced relaxation (E(max) = 0.17 +/- 0.004 g) and contraction (E(max) = 0.34 +/- 0.018 g) in contralateral arteries. Tempol restored phenylephrine-induced relaxation (E(max) = 0.19 +/- 0.012 g) and contraction (E(max) = 0.42 +/- 0.014 g) in contralateral arteries, while apocynin did not alter either relaxation (E(max) = 0.01 +/- 0.004 g) or contraction (E(max) = 0.54 +/- 0.009 g). Dihydroethidium fluorescence was increased in contralateral samples (18 882 +/- 435 U) in relation to control (10 455 +/- 303 U). SC236 reduced the fluorescence in contralateral samples (8250 +/- 365 U). CONCLUSIONS AND IMPLICATIONS Balloon catheter injury abolished phenylephrine-induced relaxation and increased phenylephrine-induced contraction in contralateral carotid arteries, through O(2)(-) derived from COX-2.
Resumo:
Balloon catheter injury results in hyper-reactivity to phenylephrine in contralateral carotids. Decreased nitric oxide (NO) modulation and/or increased intracellular calcium concentration triggers vascular smooth muscle contraction. Therefore, this study explores the participation of NO signaling pathway and calcium mobilization on hyper-reactivity to phenylephrine in contralateral carotids. Concentration-response curves for calcium (CaCl(2)) and phenylephrine were obtained in control and contralateral carotids four days after balloon injury, in the presence and absence of the inhibitors (L-NAME, L-NNA, 1400W, 7-NI, Oxyhemoglobin, ODQ or Tiron). Confocal microscopy using Fluo-3AM or DHE was performed to detect the intracellular levels of calcium and reactive oxygen species, respectively. The modulation of NO on phenylephrine-induced contraction was absent in the contralateral carotid. Phenylephrine-induced intracellular calcium mobilization was not altered in contralateral carotids. However, extracellular calcium mobilization by phenylephrine was reduced in the contralateral carotid compared to control arteries, and this result was confirmed by confocal microscopy. L-NAME increased phenylephrine-induced extracellular calcium mobilization in the contralateral carotid to the control levels. Results obtained with L-NNA, 1400W, 7-NI, OxyHb, ODQ or Tiron showed that this response was mediated by products from endothelial NOS (eNOS) different from NO and without soluble guanylate cyclase activation, but it involved superoxide anions. Furthermore. Tiron or L-NNA reduced the levels of reactive oxygen species in contralateral carotids. Data suggest that balloon catheter injury promoted eNOS uncoupling in contralateral carotids, which generates superoxide rather than NO, and reduces phenylephrine-induced extracellular calcium mobilization, despite the hyper-reactivity to phenylephrine in contralateral carotids. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Balloon catheter injury promotes hyperreactivity to phenylephrine (Phe) in the contralateral carotid. Phe-induced contraction involves calcium mobilization, a process that may be sensitive to reactive oxygen species. In this study, we investigated whether increased reactivity to Phe in the contralateral carotid is due to alterations in calcium mobilization by Phe and reactive oxygen species signaling. Concentration-response curves to Phe were obtained in control and contralateral arteries 4 days after balloon injury. Tiron did not modify E(max) to Phe in control arteries but reduced this parameter in the contralateral carotid to control levels. Moreover, immunofluorescence to dihydroethydine showed increased basal oxidative stress in the contralateral artery compared with control artery. Intracellular calcium mobilization by Phe in the contralateral artery was not different from control, but Phe-induced extracellular calcium mobilization was reduced in the contralateral artery compared with that in the control. These data were confirmed by confocal microscopy using Fluo 3-AM. Tiron and SC-236 increased Phe-induced calcium influx in the contralateral artery, which was similar to controls in the same conditions. However, catalase did not modify this response. Taken together, our results suggest that superoxide anions and prostanoids from cyclooxygenase-2 alter pathways downstream of alpha(1)-adrenoceptor activation in the contralateral carotid in response to injury. This results in reduced Phe-induced calcium influx, despite hyperreactivity to Phe.
Resumo:
Aims: There remains significant concern about the long-term safety of drug-eluting stents (DES). However, bare metal stents (BMS) have been used safely for over two decades. There is therefore a pressing need to explore alternative strategies for reducing restenosis with BMS. This study was designed to examine whether IVUS-guided cutting balloon angioplasty (CBA) with BMS could convey similar restenosis rates to DES. Methods and results: In the randomised REstenosis reDUction by Cutting balloon angioplasty Evaluation (REDUCE III) study, 521 patients were divided into four groups based on device and IVUS use before BMS (IVUS-CBA-BMS: 137 patients; Angio-CBA-BMS: 123; IVUS-BA-BMS: 142; and Angio-BA-BMS: 119). At follow-up, the IVUS-CBA-BMS group had a significantly lower restenosis rate (6.6%) than the other groups (p=0.016). We performed a quantitative coronary angiography (QCA) based matched comparison between an IVUS-guided CBA-BMS strategy (REDUCE III) and a DES strategy (Rapamycin-Eluting-Stent Evaluation At Rotterdam Cardiology. Hospital, the RESEARCH study). We matched the presence of diabetes, vessel size, and lesion severity by QCA. Restenosis (>50% diameter stenosis at follow-up) and target vessel revascularisation (TVR) were examined. QCA-matched comparison resulted in 120-paired lesions. While acute gain was significantly greater in IVUS-CBA-BMS than DES (1.65 +/- 0.41 mm vs. 1.28 +/- 0.57 mm, p=0.001), late loss was significantly less with DES than with IVUS-CBA-BMS (0.03 +/- 0.42 mm vs. 0.80 +/- 0.47 mm, p=0.001). However, no difference was found in restenosis rates (IVUS-CBA-BMS: 6.6% vs. DES: 5.0%, p=0.582) and TVR (6.6% and 6.6%, respectively). Conclusions: An IVUS-guided CBA-BMS strategy yielded restenosis rates similar to those achieved by DES and provided an effective alternative to the use of DES.
Resumo:
Purpose: Most groups have reported disappointing results with autoaugmentation or detrusor myectomy for low capacity/compliance neuropathic bladders. Failure may be due to an ischemic diverticulum or mucosal shrinkage. We investigated whether a Silimed (R) silicone balloon placed in the bladder after autoaugmentation could prevent these problems, improving surgical results. Materials and Methods: We compared the results of standard bladder autoaugmentation in 12 children (group 1) with those in 10 (group 2) who underwent the same surgery using a bladder conformer. The conformer was a silicone balloon filled with saline that remained in the bladder for 2 weeks. All patients had a neuropathic bladder with poor capacity and compliance, resulting in urinary leakage between catheterizations. Preoperative and postoperative evaluation included a voiding diary, ultrasound, voiding cystourethrogram and urodynamics. Results: In group 1 only 1 patient became dry, 4 had little improvement in continence, 4 remained unchanged and 3 became worse. In group 2, 6 patients (60%) become continent without medication, 2 (20%) become continent with oxybutynin and 2 remained unchanged. Bladder capacity and compliance did not change significantly in group 1. However, in group 2 capacity changed from a mean of 140 to 240 ml and mean +/- SD compliance increased from 15.6 +/- 16.8 to 34.3 +/- 22.8 ml/cm H(2)O (p = 0.02). Conclusions: The inflatable balloon improved our long-term results of bladder auto-augmentation. A larger series may be necessary to confirm procedure efficacy and safety.
Resumo:
Background-Coronary artery bypass graft surgery with cardiopulmonary bypass is a safe, routine procedure. Nevertheless, significant morbidity remains, mostly because of the body`s response to the nonphysiological nature of cardiopulmonary bypass. Few data are available on the effects of off-pump coronary artery bypass graft surgery (OPCAB) on cardiac events and long-term clinical outcomes. Methods and Results-In a single-center randomized trial, 308 patients undergoing coronary artery bypass graft surgery were randomly assigned: 155 to OPCAB and 153 to on-pump CAB (ONCAB). Primary composite end points were death, myocardial infarction, further revascularization (surgery or angioplasty), or stroke. After 5-year follow-up, the primary composite end point was not different between groups (hazard ratio 0.71, 95% CI 0.41 to 1.22; P=0.21). A statistical difference was found between OPCAB and ONCAB groups in the duration of surgery (240 +/- 65 versus 300 +/- 87.5 minutes; P<0.001), in the length of ICU stay (19.5 +/- 17.8 versus 43 +/- 17.0 hours; P<0.001), time to extubation (4.6 +/- 6.8 versus 9.3 +/- 5.7 hours; P<0.001), hospital stay (6 +/- 2 versus 9 +/- 2 days; P<0.001), higher incidence of atrial fibrillation (35 versus 4% of patients; P<0.001), and blood requirements (31 versus 61% of patients; P<0.001), respectively. The number of grafts per patient was higher in the ONCAB than the OPCAB group (2.97 versus 2.49 grafts/patient; P<0.001). Conclusions-No difference was found between groups in the primary composite end point at 5-years follow-up. Although OPCAB surgery was related to a lower number of grafts and higher episodes of atrial fibrillation, it had no significant implications related to long-term outcomes.
Resumo:
Background: Silastic rings are used in gastric bypass procedures for the treatment of obesity, but ring slippage may lead to gastric pouch outlet stenosis (GPOS). Conventional management has been ring removal through abdominal surgery. Objective: To describe a novel, safe, minimally invasive, endoscopic technique for the treatment of GPOS caused by ring slippage after gastric bypass. Design: Case series. Setting: Federal University of Pernambuco and sao Paulo University. Patients: This study involved 39 consecutive patients who-were screened for inclusion. Intervention: Endoscopic dilation with an achalasia balloon. Main Outcome Measurements: Technical success and safety of the procedure. Results: Among the 39 patients, 35 underwent endoscopic dilation at the ring slippage site for the relief of GPOS. The 4 patients who did not undergo endoscopic dilation underwent surgical removal of the ring, based on the exclusion criteria. The endoscopic approach was successful in 1 to 4 sessions in 100% of cases with radioscopic control (n = 12). The duration of the procedures ranged from 5 to 30 minutes, and the average internment was 14.4 hours. Dilation promoted either rupture (65.7%) or stretching (34.3%) of the thread within the ring, thereby increasing the luminal diameter of the GPOS. Complications included self-limited upper digestive tract hemorrhage (n = 1) and asymptomatic ring erosion (n = 4). There were no recurrences of obstructive symptoms during the follow-up period (mean of 33.3 months). Limitations: This was not a randomized, comparison study, and the number of patients was relatively small. Conclusion: The technique described promotes the relief of GPOS with low overall morbidity and avoids abdominal reoperation for ring removal. (Gastrointest Endosc 2010;72:44-9.)
Resumo:
Objective To delineate the effects of extracorporeal bypass on biomarkers of hemostasis, fibrinolysis, and inflammation and clinical sequelae. Methods Patients were assigned prospectively and randomly to either on-pump (n=41) or off-pump (n=51) coronary bypass surgery. The concentrations of C-reactive protein, fibrinogen, D-dimer, and plasminogen activator inhibitor type-1 in blood were quantified before and after (1 and 24 h) surgery. Similar surgical and anesthetic procedures were used for both groups. Clinical events were assessed during initial hospitalization and at the end of I year. Results The concentrations of plasminogen activator inhibitor type-1 and D-dimer were greater compared with preoperative values 1 and 24 h after surgery in both groups, but their concentrations increased to a greater extent 24 h after surgery in the on-pump group (P<0.01). The concentration of C-reactive protein did not change appreciably immediately after surgery in either group but increased in a parallel manner 24 h after either on-pump or off-pump surgery (P<0.01). Bypass surgery in the on-pump group was associated with greater blood loss during surgery and more bleeding after surgery (P <= 0.01). The incidence of all other complications was similar in the two groups. Conclusion On-pump surgery was associated with biochemical evidence of a prothrombotic state early after surgery but no greater incidence of thrombotic events was observed. The prothrombotic state might be a consequence of extracorporeal bypass, compensation in response to more bleeding, or both in patients undergoing on-pump surgery. Coron Artery Dis 20:100-105 (C) 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins.
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.
Resumo:
Background: Double-balloon enteroscopy (DBE) allows evaluation and therapy for various small bowel diseases. In this series the outcome of a 4-year experience in a tertiary hospital school in Brazil is reported. Methods: A total of 457 consecutive DBE were performed in 418 patients from August 2004 to August 2008. 93 patients with several indications, whose aim was not the evaluation of suspected diseases of the small bowel mucosa, were excluded, therefore leaving 364 DBE in 325 patients for analysis. Data were retrospectively collected with regard to clinical, endoscopic findings, therapy and complications. Results: Among the 364 DBE performed in 325 patients, 143/325 were males (44%) and 182/325 females (56%) with a mean age of 48.6 +/- 15.7 years (range 17-89). Mean investigation time was 64 +/- 22 min (range 35-135). The depth of insertion beyond the ligament of Treitz was 230 +/- 85 cm (range 30-500) by the antegrade approach and 140 +/- 75 cm (range 0-320) by the retrograde approach. Total enteroscopy was achieved in 41.66% of the attempts (30 of 72 patients). Overall diagnostic yield was 54.95% (200 of 364 procedures) ranging from 0 to 100% in this series, depending on the indication. Angiodysplasia was the main diagnosis in 24.5% (49 of 200 procedures) and endoscopic treatment, including biopsies, hemostasis, tattooing and polypectomy were performed in 65.38% (238 of 364 procedures). No major complications were reported. Conclusions: DBE is a feasible, safe and well-tolerated procedure allowing endoscopic therapy. Selection of indications increases its diagnostic yield. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Double-balloon enteroscopy (DBE) is a useful method for endoscopic retrograde cholangiopancreatography (ERCP) in patients with Roux-en-Y anatomy. Depending on the distorted anatomy, endoscopic therapies with conventional scopes were very difficult or impossible before the advent of DBE and patients had to be submitted to a percutaneous or surgical approach. The case of 6 patients with different types of Roux-en-Y-altered anatomy in which DBE-ERCP was performed with 83.3% successful rate (5/6) is reported confirming recent data in the literature on the feasibility of this method. Copyright (C) 2009 S. Karger AG, Basel