140 resultados para instantaneous frequency measurement

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new method to measure the epicycle frequency kappa in the Galactic disc is presented. We make use of the large data base on open clusters completed by our group to derive the observed velocity vector (amplitude and direction) of the clusters in the Galactic plane. In the epicycle approximation, this velocity is equal to the circular velocity given by the rotation curve, plus a residual or perturbation velocity, of which the direction rotates as a function of time with the frequency kappa. Due to the non-random direction of the perturbation velocity at the birth time of the clusters, a plot of the present-day direction angle of this velocity as a function of the age of the clusters reveals systematic trends from which the epicycle frequency can be obtained. Our analysis considers that the Galactic potential is mainly axis-symmetric, or in other words, that the effect of the spiral arms on the Galactic orbits is small; in this sense, our results do not depend on any specific model of the spiral structure. The values of kappa that we obtain provide constraints on the rotation velocity of the in particular, V(0) is found to be 230 +/- 15 km s(-1) even if the scale (R(0) = 7.5 kpc) of the Galaxy is adopted. The measured kappa at the solar radius is 43 +/- 5 km s(-1) kpc(-1). The distribution of initial velocities of open clusters is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Real-time viscosity measurement remains a necessity for highly automated industry. To resolve this problem, many studies have been carried out using an ultrasonic shear wave reflectance method. This method is based on the determination of the complex reflection coefficient`s magnitude and phase at the solid-liquid interface. Although magnitude is a stable quantity and its measurement is relatively simple and precise, phase measurement is a difficult task because of strong temperature dependence. A simplified method that uses only the magnitude of the reflection coefficient and that is valid under the Newtonian regimen has been proposed by some authors, but the obtained viscosity values do not match conventional viscometry measurements. In this work, a mode conversion measurement cell was used to measure glycerin viscosity as a function of temperature (15 to 25 degrees C) and corn syrup-water mixtures as a function of concentration (70 to 100 wt% of corn syrup). Tests were carried out at 1 MHz. A novel signal processing technique that calculates the reflection coefficient magnitude in a frequency band, instead of a single frequency, was studied. The effects of the bandwidth on magnitude and viscosity were analyzed and the results were compared with the values predicted by the Newtonian liquid model. The frequency band technique improved the magnitude results. The obtained viscosity values came close to those measured by the rotational viscometer with percentage errors up to 14%, whereas errors up to 96% were found for the single frequency method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents the implementation of the ultrasonic shear reflectance method for viscosity measurement of Newtonian liquids using wave mode conversion from longitudinal to shear waves and vice versa. The method is based on the measurement of the complex reflection coefficient (magnitude and phase) at a solid-liquid interface. The implemented measurement cell is composed of an ultrasonic transducer, a water buffer, an aluminum prism, a PMMA buffer rod, and a sample chamber. Viscosity measurements were made in the range from 1 to 3.5 MHz for olive oil and for automotive oils (SAE 40, 90, and 250) at 15 and 22.5 degrees C, respectively. Moreover, olive oil and corn oil measurements were conducted in the range from 15 to 30 degrees C at 3.5 and 2.25 MHz, respectively. The ultrasonic measurements, in the case of the less viscous liquids, agree with the results provided by a rotational viscometer, showing Newtonian behavior. In the case of the more viscous liquids, a significant difference was obtained, showing a clear non-Newtonian behavior that cannot be described by the Kelvin-Voigt model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this study was to determine whether the addition of the measurement of bilateral hip bone mineral density (BMD) has an impact on indications for osteoporosis (OP) treatment in community-dwelling elderly individuals, based on criteria from the National Osteoporosis Foundation (NOF). Methods: In total, 605 consecutive community-dwelling elderly individuals who were 65 years and older were evaluated. Dual energy X-ray absorptiometry was used to determine the lowest T-score in the lumbar spine + unilateral hip, the bilateral hips, and the lumbar spine + bilateral hips. Risk factors associated with the lowest T-score in these three conditions were applied to indicate treatment in accordance with NOF criteria. McNemar`s test was used to assess the difference of adding bilateral hip BMD measurements. Results: There was a significant difference in the frequency of pharmacological indication using NOF criteria together with the lowest T-score for the three tests (72.8% for lumbar spine + bilateral hips and 71.2% for lumbar spine + unilateral hip; p=0.002). A higher frequency of treatment indication was also observed for lumbar spine + unilateral hip (71.2%) compared to bilateral hips (61.1%) (p<0.001). The discrepancies in treatment appeared to be more evident in women when analyzed by gender distribution. Conclusion: Our finding supports the theory that evaluation of the bilateral hips with the lumbar spine seems to be more sensitive measure for identifying patients with an osteoporosis treatment indication. Furthermore, despite the well-known artifact in the lumbar spine, this site should not be excluded when determining the indication for OP treatment in elderly people. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Olm MA, Kogler JE Jr, Macchione M, Shoemark A, Saldiva PH, Rodrigues JC. Primary ciliary dyskinesia: evaluation using cilia beat frequency assessment via spectral analysis of digital microscopy images. J Appl Physiol 111: 295-302, 2011. First published May 5, 2011; doi:10.1152/japplphysiol.00629.2010.-Ciliary beat frequency (CBF) measurements provide valuable information for diagnosing of primary ciliary dyskinesia (PCD). We developed a system for measuring CBF, used it in association with electron microscopy to diagnose PCD, and then analyzed characteristics of PCD patients. 1 The CBF measurement system was based on power spectra measured through digital imaging. Twenty-four patients suspected of having PCD (age 1-19 yr) were selected from a group of 75 children and adolescents with pneumopathies of unknown causes. Ten healthy, nonsmoking volunteers (age >= 17 yr) served as a control group. Nasal brush samples were collected, and CBF and electron microscopy were performed. PCD was diagnosed in 12 patients: 5 had radial spoke defects, 3 showed absent central microtubule pairs with transposition, 2 had outer dynein arm defects, 1 had a shortened outer dynein arm, and 1 had a normal ultrastructure. Previous studies have reported that the most common cilia defects are in the dynein arm. As expected, the mean CBF was higher in the control group (P < 0.001) and patients with normal ultrastructure (P < 0.002), than in those diagnosed with cilia ultrastructural defects (i.e., PCD patients). An obstructive ventilatory pattern was observed in 70% of the PCD patients who underwent pulmonary function tests. All PCD patients presented bronchial wall thickening on chest computed tomography scans. The protocol and diagnostic techniques employed allowed us to diagnose PCD in 16% of patients in this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This study aimed to assess the relative validity of a food frequency questionnaire.(FFQ), previously validated to measure usual intakes in adults, for measuring dietary intakes in children 5 to 10 y of age. Methods: Dietary intakes were measured using an FFQ and a 3-d dietary record. Healthy children, 5 to 10 y old (n = 151), were recruited from public schools and asked to answer the questions in the FFQ and to provide non-consecutive 3-d dietary records based on reported estimated portion sizes. Paired sample t tests and Pearson`s correlation coefficients were conducted to determine whether the two instruments reported similar values for energy and nutrients. The agreement of quartile categorization between the two instruments was also examined. Results: Estimated energy and nutrient intakes derived from the FFQ were significantly higher than those derived from 3-d dietary records. As expected, Pearson`s correlations increased after adjusting for residual measurement error, presumably due to exclusion of the high within-person variability in intake of these nutrients. Moderate to high (r > 0.50) correlation coefficients were verified for some nutrients such as calcium, folate, vitamin 132, vitamin A, and vitamin C. Conclusion: This FFQ, originally developed for use in adults, appears to overestimate usual energy and nutrient intakes in children 5 to 10 y of age. Further work is necessary to conduct a calibration study to establish adequate portion sizes before instrument adoption in this population. (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

P>Aim To evaluate ex vivo the accuracy of the iPex multi-frequency electronic apex locator (NSK Ltd, Tokyo, Japan) for working length determination in primary molar teeth. Methodology One calibrated examiner determined the working length in 20 primary molar teeth (total of 33 root canals). Working length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the most coronal limit of root resorption, and electronically using the electronic apex locator iPex, according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual and the electronic measurements revealed high correlation (ICC = 0.99) between the methods, regardless of the presence or absence of physiological root resorption. Conclusions In this laboratory study, the iPex accurately identified the apical foramen or the apical opening location for working length measurement in primary molar teeth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Natural History of Human Papillomavirus (HPV) Infection in Men: The HIM Study is a prospective multi-center cohort study that, among other factors, analyzes participants` diet. A parallel cross-sectional study was designed to evaluate the validity and reproducibility of the quantitative food frequency questionnaire (QFFQ) used in the Brazilian center from the HIM Study. For this, a convenience subsample of 98 men aged 18 to 70 years from the HIM Study in Brazil answered three 54-item QFFQ and three 24-hour recall interviews, with 6-month intervals between them (data collection January to September 2007). A Bland-Altman analysis indicated that the difference between instruments was dependent on the magnitude of the intake for energy and most nutrients included in the validity analysis, with the exception of carbohydrates, fiber, polyunsaturated fat, vitamin C, and vitamin E. The correlation between the QFFQ and the 24-hour recall for the deattenuated and energy-adjusted data ranged from 0.05 (total fat) to 0.57 (calcium). For the energy and nutrients consumption included in the validity analysis, 33.5% of participants on average were correctly classified into quartiles, and the average value of 0.26 for weighted kappa shows a reasonable agreement. The intraclass correlation coefficients for all nutrients were greater than 0.40 in the reproducibility analysis. The QFFQ demonstrated good reproducibility and acceptable validity. The results support the use of this instrument in the HIM Study. J Am Diet Assoc. 2011;111:1045-1051.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was conducted to determine the relationship among temperatures measured at different anatomical sites of the animal body and their daily pattern as indicative of the thermal stress in lactating dairy cows under tropical conditions. Environmental dry bulb (DBT) and black globe (BGT) temperatures and relative humidity (RH) were recorded. Rectal temperature (RT), respiratory frequency (RF), body surface (BST), internal base of tail (TT), vulva (VT) and auricular temperatures (AT) were collected, from 37 Black and White Holstein cows at 0700, 1300 and 1800 hours. RT showed a moderately and positive correlations with all body temperatures, ranging from 0.59 with TT to 0.64 with BST. Correlations among AT, VT and TT with RF were very similar (from 0.63 to 0.64) and were greater than those observed for RF with RT (0.55) or with BST (0.54). RF and RT were positively correlated to TT (0.63 and 0.59, respectively), AT (r = 0.63 for both) and VT (r = 0.64 and 0.63, respectively). Positive and very high correlations were observed among AT, VT and TT (from 0.94 to 0.97) indicating good association of temperatures measured in these anatomical sites. Correlations of BST with AT and VT were positive and very similar (0.71 and 0.72, respectively) and lower with TT (0.66). The AT, TT, VT and BST presented similar patterns and follow the variations of DBT through the day. Temperatures measured at different anatomical sites of the animal body have the potential to be used as indicative of the thermal stress in lactating dairy cows.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two experiments evaluated an operant procedure for establishing stimulus control using auditory and electrical stimuli as a baseline for measuring the electrical current threshold of electrodes implanted in the cochlea. Twenty-one prelingually deaf children, users of cochlear implants, learned a Go/No Go auditory discrimination task (i.e., pressing a button in the presence of the stimulus but not in its absence). When the simple discrimination baseline became stable, the electrical current was manipulated in descending and ascending series according to an adapted staircase method. Thresholds were determined for three electrodes, one in each location in the cochlea (basal, medial, and apical). Stimulus control was maintained within a certain range of decreasing electrical current but was eventually disrupted. Increasing the current recovered stimulus control, thus allowing the determination of a range of electrical currents that could be defined as the threshold. The present study demonstrated the feasibility of the operant procedure combined with a psychophysical method for threshold assessment, thus contributing to the routine fitting and maintenance of cochlear implants within the limitations of a hospital setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Mothers recall early-onset constipation in children attending gastroenterology clinics. OBJECTIVES: To study the bowel habit of young children in the community to determine, first, whether early-onset constipation is confirmed in this setting and, second, the agreement between recalled and recorded bowel habit. METHODS:Defecation data of 57 children aged 6.0-40.7 mo were obtained by maternal recall (questionnaire on predominant stool characteristics) and by record (1,934 defecations registered prospectively at home and in the nursery). The bowel habit was classified according to stool frequency and proportion of stool characteristics (soft, hard and/or runny). Two criteria were used to classify recorded data, since the cutoff point for hard stools to identify constipation is undefined in children: predominant criterion and adult criterion, respectively with >50% and >25% of stools with altered consistency. Bowel habit categories were: adequate, constipation, functional diarrhea and "other bowel habit". Nonparametric statistics, and the Kappa index for agreement between recalled and recorded bowel habit, were used. RESULTS: Constipation occurred in 17.5%, 10.5%, 19.3% of the children by recall, the predominant and the adult criteria, respectively. Constipation was the main recalled alteration, vs 12.3% "other bowel habit". Only one child classified as having functional diarrhea (by the adult criterion). Agreement between recalled and recorded bowel habit was fair for constipation, by the predominant and the adult criteria (K = 0.28 and 0.24, respectively), but only slight (K <0.16) for other bowel habit categories. Individual data, however, pointed to a better relationship between recalled constipation and the adult rather than the predominant criterion. CONCLUSIONS: Frequent early-onset constipation was confirmed. Fair agreement between recalled and recorded constipation by the two used criteria indicates that recalled data are quite reliable to detect constipation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flavonoids present in sugarcane (Saccharum officinarum) extracts were analyzed by liquid chromatography - mass spectrometry (LC-MS), and a study of the fragmentation patterns of selected flavonoids was conducted using orthogonal acceleration time-of-flight electrospray ionization mass spectrometry (ESI-oa-ToF MS). Seven C- and O-glycosylflavones were identified in the extracts, namely, schaftoside, isoschaftoside, luteolin-8-C-(rhamnosylglucoside), vitexin, orientin, tricin-7-O-neohesperidoside and tricin-7-O-glucoside. Of these, five were identified in the absence of direct comparison with their respective standards. The described method also permitted the differentiation of the 6-C and 8-C isomeric flavones, schaftoside and isoschaftoside. The combination of fragmentation data and exact mass measurement showed to be complimentary to the HPLC-UV-MS techniques previously utilized for isomers discrimination in sugarcane studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to validate the intake of carotenoids, fruits and vegetables estimated by the Food Frequency Questionnaire for Adolescents (FFQA) using the method of triads. Blood samples were collected from 80 elementary school adolescents to assess serum levels of β-carotene. Partial correlation coefficients (r) were calculated between an estimated intake of carotenoids, fruits and vegetables and the serum levels of β-carotene. Validity coefficients were calculated using the method of triads. With the exception of carotenoids, partial r from the food frequency questionnaire (FFQ) were greater than those of the 24-hour recall (24hR). The fruit/vegetable group showed the highest partial r for the FFQ (r = 0.235) and the 24hR (r = 0.137). The highest validity coefficient was obtained for the vegetable group, as assessed by the FFQ (r = 0.873). On average, the validity coefficient values for the FFQ were greater than those obtained for the 24hR or the β-carotene serum levels. The FFQA is an accurate tool for estimating the intake of carotenoids, fruits and vegetables in this population group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study describes the validity of a food frequency questionnaire (FFQ) in 93 low-income women (20-65 years), participating in a case-control study in São Paulo, Brazil. Two FFQ (FFQ1 and FFQ2, 12 months apart) and three 24-hour dietary recalls (24hR) were conducted between 2003 and 2004 to estimate dietary intake during the past year. The Pearson correlation coefficients (crude, energy-adjusted and de-attenuated) were used for comparisons between FFQ and 24hR. The agreement between the methods was further examined by the Bland-Altman analysis. For the assessment of long-term reliability, the energy-adjusted intra-class correlation coefficients were mostly around 0.40, but higher for vitamin A and folate (0.50-0.56). Energy-adjusted, attenuation-corrected Pearson validity correlations between FFQ and DR ranged from 0.30-0.54 for macronutrients to 0.20-0.48 for micronutrients, with higher value for calcium (0.75). There were small proportions of grossly misclassified nutrient intakes, while Bland-Altman plots indicated that the FFQ is accurate in assessing nutrient intake at a group level.