8 resultados para false positive

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The definitive diagnosis of visceral. leishmaniasis (VL) requires invasive procedures with demonstration of amastigotes in tissue or promastigotes in culture. Unfortunately, these approaches require laboratory materials not available in poor countries where the disease is endemic. The correct diagnosis of VL is important, and made more difficult by the fact that several common tropical diseases such as malaria, disseminated tuberculosis, and enteric fever share the same clinical presentation. Serological tests have been developed to replace parasitological diagnosis in the field. A commercially available K39-based strip test for VL has been developed for this purpose. The endemic area of leishmaniasis in Brazil overlaps the endemic area of Chagas disease, a disease that can cause false-positive serological test results. The aim of this study was to evaluate the incidence of false-positive exams using a rapid test for VL in patients with Chagas disease. Methods: A rapid test based on the recombinant K39 antigen of Leishmania was used in: (1) 30 patients with confirmed Chagas disease, (2) 30 patients with a serological diagnosis of Chagas disease by ELISA, indirect immunofluorescence, indirect hemagglutination, and chemiluminescence, (3) 30 healthy patients from a non-endemic area as the control group, (4) 30 patients with confirmed VL, and (5) 20 patients with proved cutaneous leishmaniasis. Results: The sensitivity and specificity of the rapid strip test were 100% when compared with healthy volunteers and those with confirmed Chagas disease. One false-positive result occurred in the group with Chagas disease diagnosed by serological tests (specificity of 96%). Conclusion: The rapid test based on recombinant K39 is a useful diagnostic assay, and a false-positive result rarely occurs in patients with a serological diagnosis of Chagas disease. (C) 2008 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: To validate a non-nutritive sucking (NNS) scoring system for oral feeding in preterm newborns (PTNB). Methods: A cohort study was carried out in two phases. In phase one of the study, 22 mastered speech-language pathologists received the protocol and procedure for a NNS scoring system to evaluate the content and presentation of the form and to define the grading scale. In phase two, six speech-language pathologists evaluated 51 PTNBs weekly, using the defined scoring system. Setting: This study was carried out in the Nursery Annex to the Maternity at the Intensive and Neonatal Pediatrics Service, Instituto da Crianca, Hospital das Clinicas, School of Medicine, University of Sao Paulo (FMUSP) during the period from May 2004 to May 2006. Participants: A total of 28 speech-language pathologist experts and 51 PTNBs. Results: In the first phase of the study, 22 speech-language pathologists selected the criteria, utilized in the NNS evaluation with 80% agreement. In the second phase of the study, the NNS evaluation was carried out on 51 PTNB, and a scoring system of 50 points was proposed, which corresponds to the smallest number of false positive and negative results regarding oral feeding ability. Conclusion: An NNS evaluation system was validated that was able to indicate when oral feeding could safely begin in PTNBs with a high level of agreement among the speech-language pathologists who have participated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Human respiratory syncytial virus (HRSV) is the main cause of acute lower respiratory tract infections in infants and children. Rapid diagnosis is required to permit appropriate care and treatment and to avoid unnecessary antibiotic use. Reverse transcriptase (RT-PCR) and indirect immunofluorescence assay (IFA) methods have been considered important tools for virus detection due to their high sensitivity and specificity. In order to maximize use-simplicity and minimize the risk of sample cross-contamination inherent in two-step techniques, a RT-PCR method using only a single tube to detect HRSV in clinical samples was developed. Nasopharyngeal aspirates from 226 patients with acute respiratory illness, ranging from infants to 5 years old, were collected at the University Hospital of the University of Sao Paulo (HU-USP), and tested using IFA, one-step RT-PCR, and semi-nested RT-PCR. One hundred and two (45.1%) samples were positive by at least one of the three methods, and 75 (33.2%) were positive by all methods: 92 (40.7%) were positive by one-step RT-PCR, 84 (37.2%) by IFA, and 96 (42.5%) by the semi-nested RT-PCR technique. One-step RT-PCR was shown to be fast, sensitive, and specific for RSV diagnosis, without the added inconvenience and risk of false positive results associated with semi-nested PCR. The combined use of these two methods enhances HRSV detection. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The gene SNRNP200 is composed of 45 exons and encodes a protein essential for pre-mRNA splicing, the 200 kDa helicase hBrr2. Two mutations in SNRNP200 have recently been associated with autosomal dominant retinitis pigmentosa (adRP), a retinal degenerative disease, in two families from China. In this work we analyzed the entire 35-Kb SNRNP200 genomic region in a cohort of 96 unrelated North American patients with adRP. To complete this large-scale sequencing project, we performed ultra high-throughput sequencing of pooled, untagged PCR products. We then validated the detected DNA changes by Sanger sequencing of individual samples from this cohort and from an additional one of 95 patients. One of the two previously known mutations (p.S1087L) was identified in 3 patients, while 4 new missense changes (p.R681C, p.R681H, p.V683L, p.Y689C) affecting highly conserved codons were identified in 6 unrelated individuals, indicating that the prevalence of SNRNP200-associated adRP is relatively high. We also took advantage of this research to evaluate the pool-and-sequence method, especially with respect to the generation of false positive and negative results. We conclude that, although this strategy can be adopted for rapid discovery of new disease-associated variants, it still requires extensive validation to be used in routine DNA screenings. (C) 2011 Wiley-Liss, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Only a small fraction of spectra acquired in LC-MS/MS runs matches peptides from target proteins upon database searches. The remaining, operationally termed background, spectra originate from a variety of poorly controlled sources and affect the throughput and confidence of database searches. Here, we report an algorithm and its software implementation that rapidly removes background spectra, regardless of their precise origin. The method estimates the dissimilarity distance between screened MS/MS spectra and unannotated spectra from a partially redundant background library compiled from several control and blank runs. Filtering MS/MS queries enhanced the protein identification capacity when searches lacked spectrum to sequence matching specificity. In sequence-similarity searches it reduced by, on average, 30-fold the number of orphan hits, which were not explicitly related to background protein contaminants and required manual validation. Removing high quality background MS/MS spectra, while preserving in the data set the genuine spectra from target proteins, decreased the false positive rate of stringent database searches and improved the identification of low-abundance proteins.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Data obtained during routine diagnosis of human T-cell lymphotropic virus type 1 (HTLV-1) and 2 (HTLV-2) in ""at-risk"" individuals from Sao Paulo, Brazil using signal-to-cutoff (S/C) values obtained by first, second, and third generation enzyme immunoassay (EIA) kits, were compared. The highest S/C values were obtained with third generation EIA kits, but no correlation was detected between these values and specific antibody reactivity to HTLV-1, HTLV-2, or untyped HTLV (p = 0.302). In addition, use of these third generation kits resulted in HTLV-1/2 false-positive samples. In contrast, first and second generation EIA kits showed high specificity, and the second generation EIA kits showed the highest efficiency, despite lower S/C values. Using first and second generation EIA kits, significant differences in specific antibody detection of HTLV-1, relative to HTLV-2 (p = 0.019 for first generation and p < 0.001 for second generation EIA kits) and relative to untyped HTLV (p = 0.025 for first generation EIA kits), were observed. These results were explained by the composition and format of the assays. In addition, using receiver operating characteristics (ROC) analysis, a slight adjustment in cutoff values for third generation EIA kits improved their specificities and should be used when HTLV ""at-risk"" populations from this geographic area are to be evaluated. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: A major problem in Chagas disease donor screening is the high frequency of samples with inconclusive results. The objective of this study was to describe patterns of serologic results among donors to the three Brazilian REDS-II blood centers and correlate with epidemiologic characteristics. STUDY DESIGN AND METHODS: The centers screened donor samples with one Trypanosoma cruzi lysate enzyme immunoassay (EIA). EIA-reactive samples were tested with a second lysate EIA, a recombinant-antigen based EIA, and an immunfluorescence assay. Based on the serologic results, samples were classified as confirmed positive (CP), probable positive (PP), possible other parasitic infection (POPI), and false positive (FP). RESULTS: In 2007 to 2008, a total of 877 of 615,433 donations were discarded due to Chagas assay reactivity. The prevalences (95% confidence intervals [CIs]) among first-time donors for CP, PP, POPI, and FP patterns were 114 (99-129), 26 (19-34), 10 (5-14), and 96 (82-110) per 100,000 donations, respectively. CP and PP had similar patterns of prevalence when analyzed by age, sex, education, and location, suggesting that PP cases represent true T. cruzi infections; in contrast the demographics of donors with POPI were distinct and likely unrelated to Chagas disease. No CP cases were detected among 218,514 repeat donors followed for a total of 718,187 person-years. CONCLUSION: We have proposed a classification algorithm that may have practical importance for donor counseling and epidemiologic analyses of T. cruzi-seroreactive donors. The absence of incident T. cruzi infections is reassuring with respect to risk of window phase infections within Brazil and travel-related infections in nonendemic countries such as the United States.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cytochrome P450 (CYP450) is a class of enzymes where the substrate identification is particularly important to know. It would help medicinal chemists to design drugs with lower side effects due to drug-drug interactions and to extensive genetic polymorphism. Herein, we discuss the application of the 2D and 3D-similarity searches in identifying reference Structures with higher capacity to retrieve Substrates of three important CYP enzymes (CYP2C9, CYP2D6, and CYP3A4). On the basis of the complementarities of multiple reference structures selected by different similarity search methods, we proposed the fusion of their individual Tanimoto scores into a consensus Tanimoto score (T(consensus)). Using this new score, true positive rates of 63% (CYP2C9) and 81% (CYP2D6) were achieved with false positive rates of 4% for the CYP2C9-CYP2D6 data Set. Extended similarity searches were carried out oil a validation data set, and the results showed that by using the T(consensus) score, not only the area of a ROC graph increased, but also more substrates were recovered at the beginning of a ranked list.