9 resultados para espectrometria por absorção atômica

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes methods for the simultaneous determination of Cd and Pb by graphite furnace atomic absorption spectrometry and As by hydride generation atomic absorption spectrometry in Brazilian nuts. The samples (~ 0.300 g) were digested to clear solutions in a closed vessel microwave oven. The pyrolysis and atomization temperatures for simultaneous determinations of Cd and Pb were 1100 and 2100 °C, respectively, using 0.5% (w v-1) NH4H2PO4 + 0.03% (w v-1) Mg(NO3)2 as chemical modifier. The limits of detection (3Δ) were 3.8 μg kg-1 for As, 0.86 μg kg-1 for Cd and 13 μg kg-1 for Pb. The reliability of the entire procedures was confirmed by peach leaves (No. 1547 - NIST) certified reference material analysis and addition and recovery tests. The found concentrations presented no statistical differences at the 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is a review of direct analysis using solid sampling graphite furnace atomic absorption spectrometry. Greater emphasis is dedicated to sample preparation, sample homogeneity, calibration and its application to microanalysis and micro-homogeneity studies. The main advantages and some difficulties related to the applicability of this technique are discussed. A literature search on the application of solid sampling graphite furnace atomic absorption spectrometry in trace element determination in many kinds of samples, including biological, clinical, technological and environmental ones, is also presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several sample preparation strategies were employed for determination and fractionation of barium in Brazil nuts using measurements by graphite furnace atomic absorption spectrometry (GF AAS) and inductively coupled plasma optical emission spectrometry with axial view (ICP OES). This food is widely consumed because of its nutritional value and good taste. The chemical analysis of Brazil nuts is not trivial due to their complex matrix. The fractionation of barium in Brazil nuts was studied owing to the toxicity of this element and the strong correlation between chemical form and absorption. Total concentrations of barium varied from 860 to 2084 mg kg-1. Sequential extractions were performed based on solubility in different media and also according to lipids, proteins and low molecular weight fractions (LMW). The greatest contents of barium were determined in the LMW and in the water insoluble fractions with concentrations in the range 778 to 1606 and 551 to 1520 mg kg-1, respectively. Based on these results it can be inferred that Ba is not absorbed when Brazil nuts are ingested. Considering both the contents of barium and sulfur in different fractions and stoichiometric calculations it was also possible to assume that barium occurs mainly in the BaSO4 form. The presence of this chemical form was also confirmed by thermogravimetric measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To analyze household risk factors associated with high lead levels in surface dental enamel. METHODS: A cross-sectional study was conducted with 160 Brazilian adolescents aged 14-18 years living in poor neighborhoods in the city of Bauru, southeastern Brazil, from August to December 2008. Body lead concentrations were assessed in surface dental enamel acid-etch microbiopsies. Dental enamel lead levels were measured by graphite furnace atomic absorption spectrometry and phosphorus levels were measured by inductively coupled plasma optical emission spectrometry. The parents answered a questionnaire about their children's potential early (05 years old) exposure to well-known lead sources. Logistic regression was used to identify associations between dental enamel lead levels and each environmental risk factor studied. Social and familial covariables were included in the models. RESULTS: The results suggest that the adolescents studied were exposed to lead sources during their first years of life. Risk factors associated with high dental enamel lead levels were living in or close to a contaminated area (OR = 4.49; 95% CI: 1.69;11.97); and member of the household worked in the manufacturing of paints, paint pigments, ceramics or batteries (OR = 3.43; 95% CI: 1.31;9.00). Home-based use of lead-glazed ceramics, low-quality pirated toys, anticorrosive paint on gates and/or sale of used car batteries (OR = 1.31; 95% CI: 0.56;3.03) and smoking (OR = 1.66; 95% CI: 0.52;5.28) were not found to be associated with high dental enamel lead levels. CONCLUSIONS: Surface dental enamel can be used as a marker of past environmental exposure to lead and lead concentrations detected are associated to well-known sources of lead contamination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As distribuidoras de combustíveis utilizam containers de aço inoxidável para o armazenamento de biocombustíveis, entretanto, na literatura, há poucos relatos sobre os aspectos corrosivos desse aço em biodiesel. O objetivo desse trabalho é estudar o comportamento corrosivo do aço inoxidável austenítico 304 na presença de biodiesel, não lavado e lavado com soluções aquosas de ácido cítrico, oxálico, acético e ascórbico 0,01 mol L-1e comparar com os resultados obtidos para o cobre (ASTM D130). Empregaram-se técnicas como: espectrometria de absorção atômica (EAA) e microscopia óptica (MO). Os resultados de EAA mostraram uma baixa taxa de corrosão para o aço inoxidável, os elementos de liga estudados foram Cr, Ni e Fe, a maior taxa observada foi para o cromo, 1,78 ppm/dia em biodiesel não lavado ou lavado. As MO do aço 304, quando comparados com as do cobre, comprovaram a baixa taxa de corrosão para o sistema aço 304/biodiesel, entretanto comprovaram que, tanto o aço 304, quanto o cobre, sofrem corrosão em amostras de biodiesel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rare earth ion doped solid state materials are the most important active media of near-infrared and visible lasers and other photonic devices. In these ions, the occurrence of Excited State Absorptions (ESA), from long lived electronic levels, is commonplace. Since ESA can deeply affect the efficiencies of the rare earth emissions, evaluation of these transitions cross sections is of greatest importance in predicting the potential applications of a given material. In this paper a detailed description of the pump-probe technique for ESA measurements is presented, with a review of several examples of applications in Nd3+, Tm3+ and Er3+ doped materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of modern analytical tools plays an important role in quality control. The main purpose of this study was to explore the use of subcritical water as a versatile analytical tool, employed simultaneously as a reagent and solvent, as well as the application of high temperature-high resolution gas chromatography (HT-HRGC) to develop a procedure for the analysis of triacylglycerides and fatty acids in Azadirachta indica A. Juss. (Neem) oil without the need for solvents, chemical reagents, or catalytic agents. The developed method presented satisfactory results and is in agreement with the concepts of Green Analytical Chemistry (GAC).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper introduces the basics of peptide mass spectra interpretation applied to proteomics and is directed to chemists, biochemists and biologists. The manuscript presents a well detailed protocol aiming to serve as a first choice guide for understanding peptide sequencing. The tutorial was elaborated based on both a thorough bibliographic revision and the author's experience. In order to prove the applicability of the proposed guide, spectra obtained on different instruments have been successfully interpreted by applying the presented rational.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CE-MS has been increasingly used for analysis of a vast array of compounds. This article reviews the different electrophoretic modes, interfaces and mass analyzers that are commonly used in the CE-MS coupling, as well as the technique advantages and performance characteristics. A large compilation of CE-MS applications is also presented. Therefore, this review is both a guide for beginners and a collection of key references for people who are familiar to the technique. Furthermore, this is the first CE-MS review published in a Brazilian journal and marks the installation of the first two commercial CE-MS units in Sao Paulo State.