83 resultados para cut-off score

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a detailed study of the capacitance spectra obtained from Au/doped-polyaniline/Al structures in the frequency domain (0.05 Hz-10 MHz), and at different temperatures (150-340 K) is carried out. The capacitance spectra behavior in semiconductors can be appropriately described by using abrupt cut-off models, since they assume that the electronic gap states that can follow the ac modulation have response times varying rapidly with a certain abscissa, which is dependent on both temperature and frequency. Two models based on the abrupt cut-off concept, formerly developed to describe inorganic semiconductor devices, have been used to analyze the capacitance spectra of devices based on doped polyaniline (PANI), which is a well-known polymeric semiconductor with innumerous potential technological applications. The application of these models allowed the determination of significant parameters, such as Debye length (approximate to 20 nm), position of bulk Fermi level (approximate to 320 meV) and associated density of states (approximate to 2x10(18) eV(-1) cm(-3)), width of the space charge region (approximate to 70 nm), built-in potential (approximate to 780 meV), and the gap states` distribution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To analyze the psychometric properties of the Brazilian Portuguese version of the Beck Anxiety Inventory (BAI) in terms of its internal consistency, scores distribution, concurrent and discriminant validity, and factorial analysis in a sample of university students and social anxiety disorder (SAD) cases and non-cases. Methods. A sample of Brazilian university students from the general population (N = 2314) and a sample of university students identified as cases (N = 88) and non-cases (N = 90) of SAD were assessed, using as a parameter the Structured Clinical Interview for the DSM-IV. The different instruments were completed individually in the presence of an experienced rater. Results. The BAI showed adequate internal consistency (0.88-0.92) and discriminant validity, with 0.74 sensitivity and 0.71 specificity for a cut-off score of 10. The factorial analysis suggested a three-factor solution to be the most adequate. Conclusions. The version of the BAI studied is quite adequate to be used in the context of Brazilian university students, identifying the presence of anxiety indicators. However, its usefulness to screen for SAD seems limited.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To investigate the accuracy of the Brazilian version of the Addenbrooke Cognitive Examination-revised (ACE-R) in the diagnosis of mild Alzheimer disease (AD). Background: The ACE-R is an accurate and brief cognitive battery for the detection of mild dementia, especially for the discrimination between AD and frontotemporal dementia. Methods: The battery was administered to 31 patients with mild AD and 62 age-matched and education-matched cognitively healthy controls. Both groups were selected using the Dementia Rating Scale and were submitted to the ACE-R. Depression was ruled out in both groups by the Cornell Scale for Depression in Dementia. The performance of patients and controls in the ACE-R was compared and receiver operator characteristic curve analysis was undertaken to ascertain the accuracy of the instrument for the diagnosis of mild AD. Results: The mean scores at the ACE-R were 63.10 +/- 10.22 points for patients with AD and 83.63 +/- 7.90 points for controls. The cut-off score < 78 yielded high diagnostic accuracy (receiver operator characteristic area under the curve = 0.947), with 100% sensitivity, 82.26% specificity, 73.8% positive predictive value, and 100% negative predictive value. Conclusions: The Brazilian version of the ACE-R displayed high diagnostic accuracy for the identification of mild AD in the studied sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chronic hepatitis C (CHC) is one of the most important causes of chronic liver disease in the world, potentially resulting in cirrhosis, hepatocellular carcinoma, and the need for liver transplantation. Liver biopsy is currently performed before therapy indication. Although, it is the golden standard there are many reasons to avoid or delay the procedure. APRI Score is an easy, low cost and practice alternative method which was described as an alternative for assessing structural changes in chronic hepatitis C (CHC). The rationale of this study was to observe the accuracy of APRI Score in comparison to liver biopsy in 400 patients divided into two groups of 200 carriers (Validation and Experimental groups respectively) selected at random or according to liver fibrosis staging (METAVIR). The ROC curves showed a concordance among these two methods of 92% and 88.5% when 1.05 was the cut off (F3 and F4), and 87% and 83%, on 0.75 cut offs (F2-F4). The discordance in advanced fibrosis staging (F3 and F4) was only 16 (8%) and 22 (11%) out of 200 patients in the experimental and validation groups, respectively. In 26 (13%) out of 200 patients in the experimental group and 34 (17%) out of 200 patients in the validation group, there was discordance between APRI Score and liver biopsy in moderate and advanced fibrosis (F2-F4). In conclusion APRI is a serological marker that has satisfactory sensitivity and specificity together with a high predictive value and it can be useful either in the absence of a biopsy or to reduce the frequency with which biopsies need to be carried out to monitor the evolution of chronic hepatitis C and the right moment for treatment indication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Around 15% of patients die or become dependent after cerebral vein and dural sinus thrombosis (CVT). Method: We used the International Study on Cerebral Vein and Dural Sinus Thrombosis (ISCVT) sample (624 patients, with a median follow-up time of 478 days) to develop a Cox proportional hazards regression model to predict outcome, dichotomised by a modified Rankin Scale score > 2. From the model hazard ratios, a risk score was derived and a cut-off point selected. The model and the score were tested in 2 validation samples: (1) the prospective Cerebral Venous Thrombosis Portuguese Collaborative Study Group (VENO-PORT) sample with 91 patients; (2) a sample of 169 consecutive CVT patients admitted to 5 ISCVT centres after the end of the ISCVT recruitment period. Sensitivity, specificity, c statistics and overall efficiency to predict outcome at 6 months were calculated. Results: The model (hazard ratios: malignancy 4.53; coma 4.19; thrombosis of the deep venous system 3.03; mental status disturbance 2.18; male gender 1.60; intracranial haemorrhage 1.42) had overall efficiencies of 85.1, 84.4 and 90.0%, in the derivation sample and validation samples 1 and 2, respectively. Using the risk score (range from 0 to 9) with a cut-off of 6 3 points, overall efficiency was 85.4, 84.4 and 90.1% in the derivation sample and validation samples 1 and 2, respectively. Sensitivity and specificity in the combined samples were 96.1 and 13.6%, respectively. Conclusions: The CVT risk score has a good estimated overall rate of correct classifications in both validation samples, but its specificity is low. It can be used to avoid unnecessary or dangerous interventions in low-risk patients, and may help to identify high-risk CVT patients. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to translate the Structured Clinical Interview for Mood Spectrum into Brazilian Portuguese, measuring its reliability, validity, and defining scores for bipolar disorders. METHOD: Questionnaire was translated (into Brazilian Portuguese) and back-translated into English. Sample consisted of 47 subjects with bipolar disorder, 47 with major depressive disorder, 18 with schizophrenia and 22 controls. Inter-rater reliability was tested in 20 subjects with bipolar disorder and MDD. Internal consistency was measured using the Kuder Richardson formula. Forward stepwise discriminant analysis was performed. Scores were compared between groups; manic (M), depressive (D) and total (T) threshold scores were calculated through receiver operating characteristic (ROC) curves. RESULTS: Kuder Richardson coefficients were between 0.86 and 0.94. Intraclass correlation coefficient was 0.96 (CI 95 % 0.93-0.97). Subjects with bipolar disorder had higher M and T, and similar D scores, when compared to major depressive disorder (ANOVA, p < 0.001). The sub-domains that best discriminated unipolar and bipolar subjects were manic energy and manic mood. M had the best area under the curve (0.909), and values of M equal to or greater than 30 yielded 91.5% sensitivity and 74.5% specificity. CONCLUSION: Structured Clinical Interview for Mood Spectrum has good reliability and validity. Cut-off of 30 best differentiates subjects with bipolar disorder vs. unipolar depression. A cutoff score of 30 or higher in the mania sub-domain is appropriate to help make a distinction between subjects with bipolar disorder and those with unipolar depression.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conventional karyotyping detects anomalies in 3-15% of patients with multiple congenital anomalies and mental retardation (MCA/MR). Whole-genome array screening (WGAS) has been consistently suggested as the first choice diagnostic test for this group of patients, but it is very costly for large-scale use in developing countries. We evaluated the use of a combination of Multiplex Ligation-dependent Probe Amplification (MLPA) kits to increase the detection rate of chromosomal abnormalities in MCA/MR patients. We screened 261 MCA/MR patients with two subtelomeric and one microdeletion kits. This would theoretically detect up to 70% of all submicroscopic abnormalities. Additionally we scored the de Vries score for 209 patients in an effort to find a suitable cut-off for MLPA screening. Our results reveal that chromosomal abnormalities were present in 87 (33.3%) patients, but only 57 (21.8%) were considered causative. Karyotyping detected 15 abnormalities (6.9%), while MLPA identified 54 (20.7%). Our combined MLPA screening raised the total detection number of pathogenic imbalances more than three times when compared to conventional karyotyping. We also show that using the de Vries score as a cutoff for this screening would only be suitable under financial restrictions. A decision analytic model was constructed with three possible strategies: karyotype, karyotype + MLPA and karyotype + WGAS. Karyotype + MLPA strategy detected anomalies in 19.8% of cases which account for 76.45% of the expected yield for karyotype + WGAS. Incremental Cost Effectiveness Ratio (ICER) of MLPA is three times lower than that of WGAS, which means that, for the same costs, we have three additional diagnoses with MLPA but only one with WGAS. We list all causative alterations found, including rare findings, such as reciprocal duplications of regions deleted in Sotos and Williams-Beuren syndromes. We also describe imbalances that were considered polymorphisms or rare variants, such as the new SNP that confounded the analysis of the 22q13.3 deletion syndrome. (C) 2011 Elsevier Masson SAS. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background The CAMCOG is a brief neuropsychological battery designed to assess global cognitive function and ascertain the impairments that are required for the diagnosis of dementia. To date, the cut-off scores for mild cognitive impairment (MCI) have not been determined. Given the need for an earlier diagnosis of mild dementia, new cut-off values are also necessary, taking into account cultural and educational effects. Methods One hundred and fifty-seven older adults (mean age: 69.6 +/- 7.4 years) with 8 or more years of formal education (mean years of schooling 14.2 +/- 3.8) attending a memory clinic at the Institute of Psychiatry University of Sao Paulo were included. Subjects were divided into three groups according to their cognitive status, established through clinical and neuropsychological assessment: normal controls, n = 62; MCI, n = 65; and mild or moderate dementia, n = 30. ROC curve analyses were performed for dementia vs controls, MCI vs controls and MCI vs dementia. Results The cut-off values were: 92/93 for dementia is controls (AUC = 0.99: sensitivity: 100%, specificity: 95%); 95/96 for MCI vs controls (AUC = 0.83, sensitivity: 64%, specificity: 88%), and 85/86 for MCI vs dementia (AUC = 0.91, sensitivity: 81%, specificity: 88%). The total CAMCOG score was more accurate than its subtests Mini-mental State Examination, Verbal Fluency Test and Clock Drawing Test when used separately. Conclusions The CAMCOG discriminated controls and MCI from demented patients, but was less accurate to discriminate MCI from controls. The best cut-off value to differentiate controls and demented was higher than suggested in the original publication, probably because only cases of mild to moderate dementia were included. This is important given the need for a diagnostic at earlier stages of Alzheimer`s disease. Copyright (C) 2008 John Wiley & Sons, Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Noncarious cervical lesions (NCCLs) are considered to be of multifactorial origin, normally associated with inadequate brushing. This study assessed the influence in vitro of simulated brushing on NCCL formation. Fifteen human premolars were submitted to brushing in the cementoenamel junction region, using hard-, medium- and soft-bristled brushes associated with a toothpaste of medium abrasiveness under a 200 g load, at a speed of 356 rpm for 100 minutes. The surface topography of the region was analyzed before and after brushing, by means of a laser interferometer, using "cut-off" values of 0.25 and considering roughness values in mm. The initial roughness (mm) results for dentin (D / bristle consistency: 1 - soft, 2 - medium and 3 - hard) were as follows: (D1) 1.25 ± 0.45; (D2) 1.12 ± 0.44; (D3) 1.05 ± 0.41. For enamel (E / bristle consistency: 1 - soft, 2 - medium and 3 - hard), the initial results were: (E1) 1.18 ± 0.35; (E2) 1.32 ± 0.25; (E3) 1.50 ± 0.38. After brushing, the following were the values for dentin: (D1) 2.32 ± 1.99; (D2) 3.30 ± 0.96; (D3) Over 500. For enamel, the values after brushing were: (E1) 1.37 ± 0.31; (E2) 2.15 ± 0.90; (E3) 1.22 ± 0.47. Based on the results of the ANOVA and Tukey statistical analyses (a = .05) it was concluded that soft, medium and hard brushes are not capable of abrading enamel, whereas dentin showed changes in surface roughness by the action of medium- and hard-bristled brushes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Secondary caries has been reported as the main reason for restoration replacement. The aim of this in vitro study was to evaluate the performance of different methods - visual inspection, laser fluorescence (DIAGNOdent), radiography and tactile examination - for secondary caries detection in primary molars restored with amalgam. Fifty-four primary molars were photographed and 73 suspect sites adjacent to amalgam restorations were selected. Two examiners evaluated independently these sites using all methods. Agreement between examiners was assessed by the Kappa test. To validate the methods, a caries-detector dye was used after restoration removal. The best cut-off points for the sample were found by a Receiver Operator Characteristic (ROC) analysis, and the area under the ROC curve (Az), and the sensitivity, specificity and accuracy of the methods were calculated for enamel (D2) and dentine (D3) thresholds. These parameters were found for each method and then compared by the McNemar test. The tactile examination and visual inspection presented the highest inter-examiner agreement for the D2 and D3 thresholds, respectively. The visual inspection also showed better performance than the other methods for both thresholds (Az = 0.861 and Az = 0.841, respectively). In conclusion, the visual inspection presented the best performance for detecting enamel and dentin secondary caries in primary teeth restored with amalgam.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Analisar a acurácia do diagnóstico de dois protocolos de imunofluorescência indireta para leishmaniose visceral canina. MÉTODOS: Cães provenientes de inquérito soroepidemiológico realizado em área endêmica nos municípios de Araçatuba e de Andradina, na região noroeste do estado de São Paulo, em 2003, e área não endêmica da região metropolitana de São Paulo, foram utilizados para avaliar comparativamente dois protocolos da reação de imunofluorescência indireta (RIFI) para leishmaniose: um utilizando antígeno heterólogo Leishmania major (RIFI-BM) e outro utilizando antígeno homólogo Leishmania chagasi (RIFI-CH). Para estimar acurácia utilizou-se a análise two-graph receiver operating characteristic (TG-ROC). A análise TG-ROC comparou as leituras da diluição 1:20 do antígeno homólogo (RIFI-CH), consideradas como teste referência, com as diluições da RIFI-BM (antígeno heterólogo). RESULTADOS: A diluição 1:20 do teste RIFI-CH apresentou o melhor coeficiente de contingência (0,755) e a maior força de associação entre as duas variáveis estudadas (qui-quadrado=124,3), sendo considerada a diluição-referência do teste nas comparações com as diferentes diluições do teste RIFI-BM. Os melhores resultados do RIFI-BM foram obtidos na diluição 1:40, com melhor coeficiente de contingência (0,680) e maior força de associação (qui-quadrado=80,8). Com a mudança do ponto de corte sugerido nesta análise para a diluição 1:40 da RIFI-BM, o valor do parâmetro especificidade aumentou de 57,5% para 97,7%, embora a diluição 1:80 tivesse apresentado a melhor estimativa para sensibilidade (80,2%) com o novo ponto de corte. CONCLUSÕES: A análise TG-ROC pode fornecer importantes informações sobre os testes de diagnósticos, além de apresentar sugestões sobre pontos de cortes que podem melhorar as estimativas de sensibilidade e especificidade do teste, e avaliá-los a luz do melhor custo-benefício.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Estimar a prevalência de hipertensão arterial entre militares jovens e fatores associados. MÉTODOS: Estudo transversal realizado com amostra de 380 militares do sexo masculino de 19 e 35 anos de idade em uma unidade da Força Aérea Brasileira em São Paulo, SP, entre 2000 e 2001. Os pontos de corte para hipertensão foram: >140mmHg para pressão sistólica e > 90mmHg para pressão diastólica. As variáveis estudadas incluíram fatores de risco e de proteção para hipertensão, como características comportamentais e nutricionais. Para análise das associações, utilizou-se regressão linear generalizada múltipla, com família binomial e ligação logarítmica, obtendo-se razões de prevalências com intervalo de 90% de confiança e seleção hierarquizada das variáveis. RESULTADOS: A prevalência de hipertensão arterial foi de 22% (IC 90%: 21;29). No modelo final da regressão múltipla verificou-se prevalência de hipertensão 68% maior entre os ex-fumantes em relação aos não fumantes (IC 90%: 1,13;2,50). Entre os indivíduos com sobrepeso (índice de massa corporal - IMC de 25 a 29kg/m2) e com obesidade (IMC>29kg/m2) as prevalências foram, respectivamente, 75% (IC 90%: 1,23;2,50) e 178% (IC 90%: 1,82;4,25) maiores do que entre os eutróficos. Entre os que praticavam atividade física regular, comparado aos que não praticavam, a prevalência foi 52% menor (IC 90%: 0,30;0,90). CONCLUSÕES: Ser ex-fumante e ter sobrepeso ou obesidade foram situações de risco para hipertensão, enquanto que a prática regular de atividade física foi fator de proteção em militares jovens.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O presente estudo investigou fatores sócio-demográficos, de estilo de vida e gineco-obstétricos associados às concentrações séricas ou plasmáticas de homocisteína, ácido fólico, vitaminas B12 e B6 em mulheres de baixa renda de São Paulo, Brasil. Concentrações séricas de ácido fólico e vitamina B12 foram analisadas por fluoroimunoensaio; concentrações plasmáticas de homocisteína e vitamina B6, por cromatografia líquida de alta performance em fase reversa. Variáveis independentes foram inicialmente selecionadas segundo pressupostos teóricos, correlação de Pearson ou teste Kruskal-Wallis (p < 0,20). Concentrações alteradas segundo pontos de corte para homocisteína, ácido fólico, vitaminas B12 e B6 foram observadas em 20%, 6%, 11% e 67% das participantes, respectivamente. Idade foi positivamente correlacionada à vitamina B6 e homocisteína plasmáticas (p < 0,001). Índice de massa corporal foi positivamente correlacionado à vitamina B6 plasmática (p < 0,001). Modelos de regressão linear múltiplos explicaram 10,2%, 5,8%, 14,4% e 9,4% das concentrações de ácido fólico, vitamina B12, vitamina B6 e homocisteína, respectivamente. No presente estudo, variáveis sócio-demográficas, de estilo de vida e gineco-obstétricas apresentaram contribuição importante na variação das concentrações dos indicadores bioquímicos avaliados.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A serologic survey was conducted among 130 swine slaughtered in the public slaughterhouse of the city of Patos, Paraíba State, Northeastern Brazil, to determine the prevalence of anti-Toxoplasma gondii and anti-Neospora caninum antibodies, and to verify possible associations between sex of the animals and antibody prevalence. The sera were analyzed by indirect antibody tests, considering 1:64 (T. gondii) and 1:50 (N. caninum) dilutions as cut-off points. The prevalence of anti-T. gondii antibodies was 36.2% (47/130) (95% CI = 27.9 - 45.0%) with reciprocal titers ranging from 64 to 2,048, and of anti-N. caninum antibodies was 3.1% (4/130) (95% CI = 0.8 - 7.7%) with reciprocal titers ranging from 50 to 6,400. Three of the four N. caninum-positive samples were also positive for T. gondii antibodies. All Neospora and Toxoplasma IFAT-positive animals were also positive for confirmatory immunoblotting techniques using total and purified N. caninum and T. gondii tachyzoite antigens, i.e., p38 (NcSRS2) and p30 (TgSAG1). There was no association between sex of animals and prevalence of anti-T. gondii and anti-N. caninum antibodies. This is the first indication of N. caninum natural infection in pigs from Brazil.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo deste estudo foi determinar a ocorrência de anticorpos anti-Neospora caninum em 260 amostras de soro coletadas de fetos bovinos de julho de 2007 a março de 2008, em abatedouro do município de Santa Maria, Rio Grande do Sul, Brasil. Para detecção de anticorpos anti-N. caninum, a técnica de imunofluorescência indireta foi utilizada tanto para a detecção de imunoglobulinas G e M. Amostras com títulos e" 25 foram consideradas positivas. Das 260 amostras testadas, 15% (39/260) foram positivas para anticorpos anti-N. caninum. Destas, em 38 (97,4%) foi detectada a presença de IgG anti-N. caninum e em seis (15,4%) de IgM. Em cinco amostras (12,8%) detectaram-se ambos, IgG e IgM. Os resultados reafirmam a habilidade do N. caninum em determinar infecção fetal. A pesquisa de IgM foi de limitada importância na detecção da infecção via transplacentária em soro fetal bovino.