5 resultados para complicated background
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Only a small fraction of spectra acquired in LC-MS/MS runs matches peptides from target proteins upon database searches. The remaining, operationally termed background, spectra originate from a variety of poorly controlled sources and affect the throughput and confidence of database searches. Here, we report an algorithm and its software implementation that rapidly removes background spectra, regardless of their precise origin. The method estimates the dissimilarity distance between screened MS/MS spectra and unannotated spectra from a partially redundant background library compiled from several control and blank runs. Filtering MS/MS queries enhanced the protein identification capacity when searches lacked spectrum to sequence matching specificity. In sequence-similarity searches it reduced by, on average, 30-fold the number of orphan hits, which were not explicitly related to background protein contaminants and required manual validation. Removing high quality background MS/MS spectra, while preserving in the data set the genuine spectra from target proteins, decreased the false positive rate of stringent database searches and improved the identification of low-abundance proteins.
Resumo:
At surgical depths of anesthesia, inhalational anesthetics cause a loss of motor response to painful stimuli (i.e., immobilization) that is characterized by profound inhibition of spinal motor circuits. Yet, although clearly depressed, the respiratory motor system continues to provide adequate ventilation under these same conditions. Here, we show that isoflurane causes robust activation of CO(2)/pH-sensitive, Phox2b-expressing neurons located in the retrotrapezoid nucleus (RTN) of the rodent brainstem, in vitro and in vivo. In brainstem slices from Phox2b-eGFP mice, the firing of pH-sensitive RTN neurons was strongly increased by isoflurane, independent of prevailing pH conditions. At least two ionic mechanisms contributed to anesthetic activation of RTN neurons: activation of an Na(+)-dependent cationic current and inhibition of a background K(+) current. Single-cell reverse transcription-PCR analysis of dissociated green fluorescent protein-labeled RTN neurons revealed expression of THIK-1 (TWIK-related halothane-inhibited K(+) channel, K(2P)13.1), a channel that shares key properties with the native RTN current (i.e., suppression by inhalational anesthetics, weak rectification, inhibition by extracellular Na(+), and pH-insensitivity). Isoflurane also increased firing rate of RTN chemosensitive neurons in urethane-anesthetized rats, again independent of CO(2) levels. In these animals, isoflurane transiently enhanced activity of the respiratory system, an effect that was most prominent at low levels of respiratory drive and mediated primarily by an increase in respiratory frequency. These data indicate that inhalational anesthetics cause activation of RTN neurons, which serve an important integrative role in respiratory control; the increased drive provided by enhanced RTN neuronal activity may contribute, in part, to maintaining respiratory motor activity under immobilizing anesthetic conditions.
Resumo:
Path-integral representations for a scalar particle propagator in non-Abelian external backgrounds are derived. To this aim, we generalize the procedure proposed by Gitman and Schvartsman of path-integral construction to any representation of SU(N) given in terms of antisymmetric generators. And for arbitrary representations of SU(N), we present an alternative construction by means of fermionic coherent states. From the path-integral representations we derive pseudoclassical actions for a scalar particle placed in non-Abelian backgrounds. These actions are classically analyzed and then quantized to prove their consistency.
Resumo:
We present a method to determine the magnitude of the uncorrelated background distribution obtained with the event mixing technique, through the simultaneous observation of the projectile elastic scattering in different detectors, which correspond to random coincidences. The procedure is tested with alpha-d angular correlation data from the (6)Li + (59)Co reaction at E(lab) = 29.6 MeV. We also show that the method can be applied using the product of singles events, when singles measurements are available. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
In the Eplerenone Post-Acute Myocardial Infarction Heart Failure Efficacy and Survival Study ( n = 6632), eplerenone- associated reduction in all- cause mortality was significantly greater in those with a history of hypertension ( Hx- HTN). There were 4007 patients with Hx- HTN ( eplerenone: n = 1983) and 2625 patients without Hx- HTN ( eplerenone: n = 1336). Propensity scores for eplerenone use, separately calculated for patients with and without Hx- HTN, were used to assemble matched cohorts of 1838 and 1176 pairs of patients. In patients with Hx- HTN, all- cause mortality occurred in 18% of patients treated with placebo ( rate, 1430/ 10 000 person- years) and 14% of patients treated with eplerenone ( rate, 1058/ 10 000 person- years) during 2350 and 2457 years of follow- up, respectively ( hazard ratio [ HR]: 0.71; 95% CI: 0.59 to 0.85; P < 0.0001). Composite end point of cardiovascular hospitalization or cardiovascular mortality occurred in 33% of placebo-treated patients ( 3029/ 10 000 person- years) and 28% of eplerenone- treated patients (2438/10 000 person- years) with Hx- HTN ( HR: 0.82; 95% CI: 0.72 to 0.94; P = 0.003). In patients without Hx- HTN, eplerenone reduced heart failure hospitalization ( HR: 73; 95% CI: 0.55 to 0.97; P = 0.028) but had no effect on mortality ( HR: 0.91; 95% CI: 0.72 to 1.15; P = 0.435) or on the composite end point ( HR: 0.91; 95% CI: 0.76 to 1.10; P = 0.331). Eplerenone should, therefore, be prescribed to all of the post - acute myocardial infarction patients with reduced left ventricular ejection fraction and heart failure regardless of Hx- HTN.