246 resultados para comparative method
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
The development and application of a functionalized carbon nanotubes paste electrode (CNPE) modified with crosslinked chitosan for determination of Cu(II) in industrial wastewater, natural water and human urine samples by linear scan anodic stripping voltammetry (LSASV) are described. Different electrodes were constructed using chitosan and chitosan crosslinked with glutaraldehyde (CTS-GA) and epichlorohydrin (CTS-ECH). The best voltammetric response for Cu(II) was obtained with a paste composition of 65% (m/m) of functionalized carbon nanotubes, 15% (m/m) of CTS-ECH, and 20% (m/m) of mineral oil using a solution of 0.05 mol L(-1) KNO(3) with pH adjusted to 2.25 with HNO(3), an accumulation potential of 0.3V vs. Ag/AgCl (3.0 mol L(-1) KCl) for 300 s and a scan rate of 100 mV s(-1). Under these optimal experimental conditions, the voltammetric response was linearly dependent on the Cu(II) concentration in the range from 7.90 x 10(-8) to 1.60 x 10(-5) mol L(-1) with a detection limit of 1.00 x 10(-8) mol L(-1). The samples analyses were evaluated using the proposed sensor and a good recovery of Cu(II) was obtained with results in the range from 98.0% to 104%. The analysis of industrial wastewater, natural water and human urine samples obtained using the proposed CNPE modified with CTS-ECH electrode and those obtained using a comparative method are in agreement at the 95% confidence level. (C) 2009 Elsevier B. V. All rights reserved.
Resumo:
The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE: This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. MATERIAL AND METHODS: 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). RESULTS: Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. CONCLUSION: Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values.
Resumo:
This study compared the mandibular displacement from three methods of centric relation record using an anterior jig associated with (A) chin point guidance, (B) swallowing (control group) and (C) bimanual manipulation. Ten patients aged 25-39 years were selected if they met the following inclusion criteria: complete dentition (up to the second molars), Angle class I and absence of signs and symptoms of temporomandibular disorders and diagnostic casts showing stability in the maximum intercuspation (MI) position. Impressions of maxillary and mandibular arches were made with an irreversible hydrocolloid impression material. Master casts of each patient were obtained, mounted on a microscope table in MI as a reference position and 5 records of each method were made per patient. The mandibular casts were then repositioned with records interposed and new measurements were obtained. The difference between the two readings allowed measuring the displacement of the mandible in the anteroposterior and lateral axes. Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) among the three methods for measuring lateral displacement (A=0.38 ± 0.26, B=0.32 ± 0.25 and C=0.32 ± 0.23). For the anteroposterior displacement (A=2.76 ± 1.43, B=2.46 ± 1.48 and C=2.97 ± 1.51), the swallowing method (B) differed significantly from the others (p<0.05), but no significant difference (p>0.05) was found between chin point guidance (A) and bimanual manipulation (C). In conclusion, the swallowing method produced smaller mandibular posterior displacement than the other methods.
Resumo:
In Apis mellifera, hygienic behavior involves recognition and removal of sick, damaged or dead brood from capped cells. We investigated whether bees react in the same way to grouped versus isolated damaged capped brood cells. Three colonies of wild-type Africanized honey bees and three colonies of Carniolan honey bees were used for this investigation. Capped worker brood cells aged 12 to 14 days old were perforated with the pin-killing method. After making holes in the brood cells, the combs were placed back into the hives; 24 h later the number of cleaned cells was recorded in areas with pin-killed and control brood cells. Four repetitions were made in each colony. Isolated cells were more frequently cleaned than grouped cells, though variance analysis showed no significant difference (P = 0.1421). Carniolan bees also were somewhat, though not significantly more hygienic than Africanized honey bees (P = 0.0840). We conclude that honey bees can detect and remove both isolated and grouped dead brood. The tendency towards greater hygienic efficiency directed towards grouped pin-killed brood may be a consequence of a greater concentration of volatiles emanating from the wounds in the dead pupae.
Resumo:
Esophageal ulcer (EU) represents an important comorbidity in AIDS. We evaluated the prevalence of EU, the accuracy of the endoscopic and histologic methods used to investigate viral EU in HIV-positive Brazilian patients and the numerical relevance of tissue sampling. A total of 399 HIV-positive patients underwent upper gastrointestinal (UGI) endoscopy. HIV-positive patients with EU determined by UGI endoscopy followed by biopsies were analyzed by the hematoxylin-eosin (HE) and immunohistochemical (IH) methods. EU was detected in 41 patients (mean age, 39.2 years; 23 males), with a prevalence of 10.27%. The median CD4 count was 49 cells/mm(3) (range, 1-361 cells/mm(3)) and the viral load was 58,869 copies per milliliter (range, 50-77,3290 copies per milliliter). UGI endoscopy detected 29 of 41 EU suggestive of cytomegalovirus (CMV) infection and 7 of 41 indicating herpes simplex virus (HSV) infection. HE histology confirmed 4 of 29 ulcers induced by CMV, 2 of 7 induced by HSV, and 1 of 7 induced by HSV plus CMV. IH for CMV and HSV confirmed the HE findings and detected one additional CMV-induced case. UGI endoscopy showed 100% sensitivity and 15% specificity for the diagnosis of EU due to CMV or HSV compared to HE and IH. HE proved to be an adequate method for etiologic evaluation, with 87% sensitivity and 100% specificity compared to IH. The number of samples did not influence the etiologic evaluation. The data support the importance of IH as a complementary method for HE in the diagnosis of EU of viral etiology.
Resumo:
In this work, we employ the state of the art pseudopotential method, within a generalized gradient approximation to the density functional theory, to investigate the adsorption process of acrylic acid (AAc) and vinylacetic acid (VAA) on the silicon surface. Our total energy calculations support the proposed experimental process, as it indicates that the chemisorption of the molecule is as follows: The gas phase VAA (AAc) adsorbs molecularly to the electrophilic surface Si atom and then dissociates into H(2)C = CH - COO and H, bonded to the electrophilic and nucleophilic surface silicon dimer atoms, respectively. The activation energy for both processes correspond to thermal activations that are smaller than the usual growth temperature. In addition, the electronic structure, calculated vibrational modes, and theoretical scanning tunneling microscopy images are discussed, with a view to contribute to further experimental investigations.
Resumo:
Laser induced breakdown spectrometry (LIBS) was applied for the determination of macro (P, K, Ca, Mg) and micronutrients (B, Cu, Fe, Mn and Zn) in sugar cane leaves, which is one of the most economically important crops in Brazil. Operational conditions were previously optimized by a neuro-genetic approach, by using a laser Nd:YAG at 1064 nm with 110 mJ per pulse focused on a pellet surface prepared with ground plant samples. Emission intensities were measured after 2.0 mu s delay time, with 4.5 mu s integration time gate and 25 accumulated laser pulses. Measurements of LIBS spectra were based on triplicate and each replicate consisted of an average of ten spectra collected in different sites (craters) of the pellet. Quantitative determinations were carried out by using univariate calibration and chemometric methods, such as PLSR and iPLS. The calibration models were obtained by using 26 laboratory samples and the validation was carried out by using 15 test samples. For comparative purpose, these samples were also microwave-assisted digested and further analyzed by ICP OES. In general, most results obtained by LIBS did not differ significantly from ICP OES data by applying a t-test at 95% confidence level. Both LIBS multivariate and univariate calibration methods produced similar results, except for Fe where better results were achieved by the multivariate approach. Repeatability precision varied from 0.7 to 15% and 1.3 to 20% from measurements obtained by multivariate and univariate calibration, respectively. It is demonstrated that LIBS is a powerful tool for analysis of pellets of plant materials for determination of macro and micronutrients by choosing calibration and validation samples with similar matrix composition.
Resumo:
This study was conducted to evaluate the natural variability of total, extractable and non-extractable phenolics in pigmented and non-pigmented rice genotypes (Oryza sativa L.) and to estimate whether the contents and distribution of these compounds are typical for genotypes from indica and japonica subspecies. Twenty-one samples of commercial as well as new genotypes of brown rice, including seven pigmented genotypes were obtained from two Agronomic Institutes in South Brazil. Free and conjugated phenolics were extracted with ethanol, while bound phenolics were released by alkaline hydrolysis. Total phenolics were estimated in both fractions by the Folin-Ciocalteau method. Genotypes from Japonica and indica non-pigmented subspecies were not statistically distinguishable from each other, but differences in phenolic contents were associated with pericarp color. Despite individual differences, total phenolics were four times higher in pigmented than in non-pigmented genotypes (4246 and 1073 mg ferulic acid equiv. kg(-1), respectively). These high amounts were mostly due to the presence of extractable (free and conjugated) phenolics, which comprised up to 81% of total phenolics for pigmented genotypes. Non-extractable (bound) phenolics comprised 40% of total phenolics of non-pigmented rice genotypes while pigmented genotypes presented greater absolute amounts, but their contribution on total phenolics was small. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
Vecuronium bromide is a neuromuscular blocking agent used for anesthesia to induce skeletal muscle relaxation. HPLC and CZE analytical methods were developed and validated for the quantitative determination of vecuronium bromide. The HPLC method was achieved on an amino column (Luna 150 x 4.6 mm, 5 mu m) using UV detection at 205 nm. The mobile phase was composed of acetonitrile:water containing 25.0 mmol L(-1) of sodium phosphate monobasic (50:50 v/v), pH 4.6 and flow rate of 1.0 mL min(-1). The CZE method was achieved on an uncoated fused-silica capillary (40.0 cm total length, 31.5 cm effective length and 50 mu m i.d.) using indirect UV detection at 230 nm. The electrolyte comprised 1.0 mmol L(-1) of quinine sulfate dihydrate at pH 3.3 and 8.0% of acetonitrile. The results were used to compare both techniques. No significant differences were observed (p > 0.05).
Resumo:
In the present study a fast, sensitive and robust validated method to quantify chlorpheniramine in human plasma using brompheniramine as internal standard (IS) is described. The analyte and the IS were extracted from plasma by LLE (diethyl ether-dichloromethane, 80:20, v/v) and analyzed by HPLC-ESI-MS/MS. Chromatographic separation was performed using a gradient of methanol from 35 to 90% with 2.5 mm NH(4)OH on a Gemini Phenomenex C(8) 5 mu m column (50 x 4.6 mm i.d.) in 5.0 min/run. The method fitted to a linear calibration curve (0.05-10 ng/mL, R > 0.9991). The precision (%CV) and accuracy ranged, respectively: intra-batch from 1.5 to 6.8% and 99.1 to 106.6%, and inter-batch from 2.4 to 9.0%, and 99.9 to 103.1%. The validated bioanalytical procedure was used to assess the comparative bioavailability in healthy volunteers of two dexchlorpheniramine 2.0 mg tablet formulations (test dexchlorpheniramine, Eurofarma, and reference Celestamine (R), Schering-Plough). The study was conducted using an open, randomized, two-period crossover design with a 2 week washout interval. Since the 90% confidence interval for C(max) and AUC ratios were all within the 80-125% interval proposed by ANVISA and FDA, it was concluded that test and reference formulations are bioequivalent concerning the rate and the extent of absorption. Copyright (C) 2009 John Wiley & Sons, Ltd.
Resumo:
Background Although fatigue is a ubiquitous symptom across countries, clinical descriptions of chronic fatigue syndrome have arisen from a limited number of high-income countries. This might reflect differences in true prevalence or clinical recognition influenced by sociocultural factors. Aims To compare the prevalence, physician recognition and diagnosis of chronic fatigue syndrome in London and Sao Paulo. Method Primary care patients in London (n=2459) and Sao Paulo n=3914) were surveyed for the prevalence of chronic fatigue syndrome. Medical records were reviewed for the physician recognition and diagnosis. Results The prevalence of chronic fatigue syndrome according to Centers for Disease Control 1994 criteria was comparable in Britain and Brazil, 2.1% v. 1.6% (P=0.20). Medical records review identified 11 diagnosed cases of chronic fatigue syndrome in Britain, but none in Brazil (P<0.001). Conclusions The primary care prevalence of chronic fatigue syndrome was similar in two Culturally and economically distinct nations. However, doctors are unlikely to recognise and label chronic fatigue syndrome as a discrete disorder in Brazil. The recognition of this illness rather than the illness itself may be culturally induced.
Resumo:
Background: Attention deficit hyperactivity disorder (ADHD) is a clinically significant disorder in adulthood, but current diagnostic criteria and instruments do not seem to adequately capture the complexity of the disorder in this developmental phase. Accordingly, there are limited data on the proportion of adults affected by the disorder, specially in developing countries. Method: We assessed a representative household sample of the Brazilian population for ADHD with the Adult ADHD Self-report Scale (ASRS) Screener, and evaluated the instrument according to the Rasch model of item response theory. Results: The sample was comprised by 3007 individuals, and the overal prevalence of positive screeners for ADHD was 5.8% [95% confidence interval (CI), 4.8-7.0]. Rasch analyses revealed the misfitt of the overall sample to expectations of the model. The evaluation of the sample stratified by age revealed that data for adolescents showed a signficant fittnes to the model expectations, while items completed by adults were not adequated. Conclusions: The lack of fitness to the model for adult respondents challenges the possibility of a linear transformation of the ordinal data into interval measures and the utilization of parametric analyses of data. This result suggests that diagnostic criteria and instruments for adult ADHD must take into account a developmental perspective. Moreover, it calls for further evaluation of currently employed research methods in light of modern theories of psychometrics. Copyright (C) 2010 John Wiley & Sons, Ltd.
Resumo:
Objective: The study compared the prevalence, correlates of functional impairment, and service utilization for eating disorders across Latinos, Asians, and African Americans living in the United States to non-Latino Whites. Method: Pooled data from the NIMH Collaborative Psychiatric Epidemiological Studies (CPES; NIMH, 2007) were used. Results: The prevalence of anorexia nervosa (AN) and binge-eating disorder (BED) were similar across all groups examined, but bulimia nervosa (BN) was more prevalent among Latinos and African Americans than non-Latino Whites. Despite similar prevalence of BED among ethnic groups examined, lifetime prevalence of any binge eating (ABE) was greater among each of the ethnic minority groups in comparison to non-Latino Whites. Lifetime prevalence of mental health service utilization was lower among ethnic minority groups studied than for non-Latino Whites for respondents with a lifetime history of any eating disorder. Discussion: These findings suggest the need for clinician training and health policy interventions to achieve optimal and equitable care for eating disorders across all ethnic groups in the United States. (C) 2010 by Wiley Periodicals, Inc.
Resumo:
Background and objective: Dynamic indices represented by systolic pressure variation and pulse pressure variation have been demonstrated to be more accurate than filling pressures in predicting fluid responsiveness. However, the literature is scarce concerning the impact of different ventilatory modes on these indices. We hypothesized that systolic pressure variation or pulse pressure variation could be affected differently by volume-controlled ventilation and pressure-controlled ventilation in an experimental model, during normovolaemia and hypovolaemia. Method: Thirty-two anaesthetized rabbits were randomly allocated into four groups according to ventilatory modality and volaemic status where G1-ConPCV was the pressure-controlled ventilation control group, G2-HemPCV was associated with haemorrhage, G3-ConVCV was the volume-controlled ventilation control group and G4-HemVCV was associated with haemorrhage. In the haemorrhage groups, blood was removed in two stages: 15% of the estimated blood volume withdrawal at M1, and, 30 min later, an additional 15% at M2. Data were submitted to analysis of variance for repeated measures; a value of P < 0.05 was considered to be statistically significant. Results: At MO (baseline), no significant differences were observed among groups. At M1, dynamic parameters differed significantly among the control and hypovolaemic groups (P < 0.05) but not between ventilation modes. However, when 30% of the estimated blood volume was removed (M2), dynamic parameters became significantly higher in animals under volume-controlled ventilation when compared with those under pressure-controlled ventilation. Conclusions: Under normovolaemia and moderate haemorrhage, dynamic parameters were not influenced by either ventilatory modalities. However, in the second stage of haemorrhage (30%), animals in volume-controlled ventilation presented higher values of systolic pressure variation and pulse pressure variation when compared with those submitted to pressure-controlled ventilation.
Resumo:
Aim: To demonstrate that the evaluation of erythrocyte dysmorphism by light microscopy with lowering of the condenser lens (LMLC) is useful to identify patients with a haematuria of glomerular or non-glomerular origin. Methods: A comparative double-blind study between phase contrast microscopy (PCM) and LMLC is reported to evaluate the efficacy of these techniques. Urine samples of 39 patients followed up for 9 months were analyzed, and classified as glomerular and non-glomerular haematuria. The different microscopic techniques were compared using receiver-operator curve (ROC) analysis and area under curve (AUC). Reproducibility was assessed by coefficient of variation (CV). Results: Specific cut-offs were set for each method according to their best rate of specificity and sensitivity as follows: 30% for phase contrast microscopy and 40% for standard LMLC, reaching in the first method the rate of 95% and 100% of sensitivity and specificity, respectively, and in the second method the rate of 90% and 100% of sensitivity and specificity, respectively. In ROC analysis, AUC for PCM was 0.99 and AUC for LMLC was 0.96. The CV was very similar in glomerular haematuria group for PCM (35%) and LMLC (35.3%). Conclusion: LMLC proved to be effective in contributing to the direction of investigation of haematuria, toward the nephrological or urological side. This method can substitute PCM when this equipment is not available.