5 resultados para absorbent

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to assess the contamination status of endodontic absorbent paper points from sterilized or not sterilized commercial packs, as well as paper points exposed to the dental office environment. METHODS: Twenty absorbent paper points were evaluated for contamination status packed under different conditions: commercial/sterilized pack, commercial/non-sterilized pack, exposed to the clinical environment, and intentionally contaminated (positive control). Contamination was determined qualitatively and quantitatively by aerobiosis, capnophilic growth, and pour plate. The Petri dishes were analyzed with a colony counter, and the results were expressed as colony-forming units. The data were analyzed by Kruskal-Wallis test (α=0.05). RESULTS: No difference in colony-forming units was found among the groups of endodontic absorbent paper points. All groups were contaminated by fungi and bacteria. CONCLUSION: It can be concluded that the sterilization of absorbent endodontic paper points before clinical use should be recommended regardless of commercial presentation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The esthetics and functional integrity of the periodontal tissue may be compromised by dental loss. Immediate implants became a viable option to maintain the periodontal architecture because of their anatomic compatibility with the dental socket and the possibility of eliminating local contamination. This article describes the procedure of immediate implant placement in the anterior maxilla replacing teeth with chronic periapical lesions, which were condemned due to endodontic lesions persisting after failed endodontic treatment and endodontic surgery, and discusses the relationship between the procedure and periapical lesions. Surgical removal of hopeless teeth 11, 12 and 21 was performed conservatively in such a way to preserve the anatomy and gingival esthetics. A second surgical access was gained at the apical level, allowing the debridement of the surgical chamber for elimination of the periapical lesion, visual orientation for setting of the implants and filling of the surgical chamber with xenogenous bovine bone graft. After this procedure, the bone chamber was covered with an absorbent membrane and the healing screws were positioned on the implants. Later, a provisional partial removable denture was installed and the implants were inserted after 6 months. After 3 years of rehabilitation, the implants present satisfactory functional and esthetic conditions, suggesting that immediate implant placement combined with guided bone regeneration may be indicated for replacing teeth lost due to chronic periapical lesions with endodontic failure history in the anterior maxilla.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Posterior reconstruction (PR) of the rhabdosphincter has been previously described during retropubic radical prostatectomy, and shorter times to return of urinary continence were reported using this technical modification. This technique has also been applied during robot-assisted radical prostatectomy (RARP); however, contradictory results have been reported. Objective: We describe here a modified technique for PR of the rhabdosphincter during RARP and report its impact on early recovery of urinary continence and on cystographic leakage rates. Design, setting, and participants: We analyzed 803 consecutive patients who underwent RARP by a single surgeon over a 12-mo period: 330 without performing PR and 473 with PR. Surgical procedure: The reconstruction was performed using two 6-in 3-0 Poliglecaprone sutures tied together. The free edge of the remaining Denonvillier`s fascia was identified after prostatectomy and approximated to the posterior aspect of the rhabdosphincter and the posterior median raphe using one arm of the continuous suture. The second layer of the reconstruction was then performed with the other arm of the suture, approximating the posterior lip of the bladder neck and vesicoprostatic muscle to the posterior urethral edge. Measurements: Continence rates were assessed with a self-administrated, validated questionnaire (Expanded Prostate Cancer Index Composite) at 1, 4, 12, and 24 wk after catheter removal. Continence was defined as the use of ""no absorbent pads."" Cystogram was performed in all patients on postoperative day 4 or 5 before catheter removal. Results and limitations: There was no significant difference between the groups with respect to patient age, body mass index, prostate-specific antigen levels, prostate weight, American Urological Association symptom score, estimated blood loss, operative time, number of nerve-sparing procedures, and days with catheter. In the PR group, the continence rates at 1, 4, 12, and 24 wk postoperatively were 22.7%, 42.7%, 91.8%, and 96.3%, respectively; in the non-PR group, the continence rates were 28.7%, 51.6%, 91.1%, and 97%, respectively. The modified PR technique resulted in significantly higher continence rates at 1 and 4 wk after catheter removal (p = 0.048 and 0.016, respectively), although the continence rates at 12 and 24 wk were not significantly affected (p = 0.908 and p = 0.741, respectively). The median interval to recovery of continence was also statistically significantly shorter in the PR group (median: 4 wk; 95% confidence interval [CI]: 3.39-4.61) when compared to the non-PR group (median: 6 wk; 95% CI: 5.18-6.82; log-rank test, p = 0.037). Finally, the incidence of cystographic leaks was lower in the PR group (0.4% vs 2.1%; p = 0.036). Although the patients` baseline characteristics were similar between the groups, the patients were not preoperatively randomized and unknown confounding factors may have influenced the results. Conclusions: Our modified PR combines the benefits of early recovery of continence reported with the original PR technique with a reinforced watertight closure of the posterior anastomotic wall. Shorter interval to recovery of continence and lower incidence of cystographic leaks were demonstrated with our PR technique when compared to RARP with no reconstruction. (C) 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Several studies have shown that robot-assisted laparoscopic radical prostatectomy (RALP) is feasible, with favorable complication rates and short hospital times. However, the early recovery of urinary continence remains a challenge to be overcome. Objective: We describe our technique of periurethral retropubic suspension stitch during RALP and report its impact on early recovery of urinary continence. Design, setting, and participants: We analyze prospectively 331 consecutive patients who underwent RALP, 94 without the placement of suspension stitch (group 1) and 237 with the application of the suspension stitch (group 2). Surgical procedure: The only difference between the groups was the placement of the puboperiurethral stitch after the ligation of the dorsal venous complex (DVC). The periurethral retropubic stitch was placed using a 12-in monofilament polyglytone suture on a CTI needle. The stitch was passed from right to left between the urethra and DVC, and then through the periostium on the pubic bone. The stitch was passed again through the DVC, and then through the pubic bone in a figure eight, and then tied. Measurements: Continence rates were assessed with a self-administered validated questionnaire (Expanded Prostate Cancer Index Composite [EPIC] at 1, 3, 6, and 12 mo after the procedure. Continence was defined as the use of no absorbent pads or no leakage of urine. Results and limitations: In group 1, the continence rate at 1, 3, 6, and 12 mo postoperatively was 33%, 83%, 94.7%, and 95.7%, respectively; in group 2, the continence rate was 40%, 92.8%, 97.9%, and 97.9%, respectively. The suspension technique resulted in significantly greater continence rates at 3 mo after RALP (p = 0.013). The median/mean interval to recovery of continence was also statistically significantly shorter in the suspension group (median: 6 wk; mean: 7.338 wk: 95% confidence interval [CI]: 6.387-8.288) compared to the non-suspension group (median: 7 wk; mean: 9.585 wk: 95% CI: 7.558-11.612; log rank test, p = 0.02). Conclusions: The suspension stitch during RALP resulted in a statistically significantly shorter interval to recovery of continence and higher continence rates at 3 mo after the procedure. (C) 2009 European Association of Urology. Published by Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate, through the application of different dentin bonding systems, the influence of wetness on shear bond strength in enamel. Methods: This study evaluated three etch-and-rinse adhesive systems (Scotchbond MP [used with and without primer]; Singlebond; and Prime&Bond 2.1) and two self-etching adhesive systems (Clearfil SE Bond; and Xeno IV). Flat bovine enamel surfaces were either air-dried for 30 seconds or blotted with absorbent paper after acid-etching for the conventional bonding agents or before the application of self-etching bonding agents. The resin composite EsthetX was bonded to flat surfaces that had been treated with one of the adhesives, following the manufacturer`s instructions. After being stored in water at 37 degrees C for one week, bonded specimens were broken in shear. Data were evaluated with two-way analysis of variance (ANOVA) and Student-Newman-Keuls tests (alpha=0.05). For comparing each condition individually, regardless of the adhesive or wetness condition, a one-way ANOVA and a Student-Newman-Keuls test (alpha=0.05) were applied. Results: The two-way ANOVA showed significant differences among adhesive systems. An interaction effect was also observed (p < 0.05), but wetness did not influence shear bond strength (p=0.98). The one-way ANOVA showed that the all-in-one adhesive was the only material influenced by the presence of water at the enamel`s surface. Conclusion: The all-in-one adhesive behaved differently depending on whether the enamel surface was dry or wet.