80 resultados para Wheel–Rail Contact Force

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The motivation for this research is to make a comparison between dynamic results of a free railway wheelset derailment and safety limits. For this purpose, a numerical simulation of a wheelset derailment submitted to increasing lateral force is used to compare with the safety limit, using different criteria. A simplified wheelset model is used to simulate derailments with different adhesion conditions. The contact force components, including the longitudinal and spin effects, are identified in a steady-state condition on the verge of a derailment. The contact force ratios are used in a three-dimensional (3D) analytical formula to calculate the safety limits. Simulation results obtained with two contact methods were compared with the published results and the safety limit was identified with the two criteria. Results confirm Nadal`s conservative aspect and show that safety 3D analytical formula presents slightly higher safety limits for lower friction coefficients and smaller limits for high friction, in comparison with the simulation results with Fastsim.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dynamic vehicle behavior is used to identify safe traffic speed limits. The proposed methodology is based on the vehicle vertical wheel contact force response excited by measured pavement irregularities on the frequency domain. A quarter-car model is used to identify vehicle dynamic behavior. The vertical elevation of an unpaved road surface has been measured. The roughness spectral density is quantified as ISO Level C. Calculations for the vehicle inertance function were derived by using the vertical contact force transfer function weighed by the pavement spectral density roughness function in the frequency domain. The statistical contact load variation is obtained from the vehicle inertance density function integration. The vehicle safety behavior concept is based on its handling ability properties. The ability to generate tangential forces on the wheel/road contact interface is the key to vehicle handling. This ability is related to tire/pavement contact forces. A contribution to establish a traffic safety speed limit is obtained from the likelihood of the loss of driveability. The results show that at speeds faster than 25 km/h the likelihood of tire contact loss is possible when traveling on the measured road type. DOI: 10.1061/(ASCE)TE.19435436.0000216. (C) 2011 American Society of Civil Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The micro-scale abrasive wear test by rotative ball has gained large acceptance in universities and research centers, being widely used in studies on the abrasive wear of materials. Two wear modes are usually observed in this type of test: ""rolling abrasion"" results when the abrasive particles roll on the surface of the tested specimen, while ""grooving abrasion"" is observed when the abrasive particles slide; the type of wear mode has a significant effect on the overall behaviour of a tribological system. Several works on the friction coefficient during abrasive wear tests are available in the literature, but only a few were dedicated to the friction coefficient in micro-abrasive wear tests conducted with rotating ball. Additionally, recent works have identified that results may also be affected by the change in contact pressure that occurs when tests are conducted with constant applied force. Thus, the purpose of this work is to study the relationship between friction coefficient and abrasive wear modes in ball-cratering wear tests conducted at ""constant normal force"" and ""constant pressure"". Micro-scale abrasive wear tests were conducted with a ball of AISI52100 steel and a specimen of AISIH10 tool steel. The abrasive slurry was prepared with black silicon carbide (SiC) particles (average particle size of 3 mu m) and distilled water. Two constant normal force values and two constant pressure values were selected for the tests. The tangential and normal loads were monitored throughout the tests and their ratio was calculated to provide an indication of the friction coefficient. In all cases, optical microscopy analysis of the worn craters revelated only the presence of grooving abrasion. However, a more detailed analysis conducted by SEM has indicated that different degrees of rolling abrasion have also occurred along the grooves. The results have also shown that: (i) for the selected values of constant normal force and constant pressure, the friction coefficient presents, approximately, the same range of values and (ii) loading conditions play an important role on the occurrence of rolling abrasion or grooving abrasion and, consequently, on the average value and scatter of the friction coefficient in micro-abrasive wear tests. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The aim of this study was to identify the behavior of masticatory muscles after fractures of the zygomatico-orbital complex (ZOC) and subsequent surgical treatment, by using analyses of bite force, electromyography (EMG), and mandible mobility during a 6-month period after surgery. Study design. Five patients with fractured ZOCs treated surgically by using an intraoral approach and fixation exclusively in the region of the zygomaticomaxillary buttress were evaluated. The control group included 12 other patients. During postoperative follow-up, bite force, mandible mobility, and EMG analysis of the masticatory muscles were evaluated. Results. There was an increase in bite force with time, but a decline in EMG activity during the same period. In the mandible mobility analysis, only maximum mouth-opening values increased significantly after the surgical treatment. Conclusions. The masticatory musculature, according to bite force and EMG, returned to its normal condition by the second month after surgery, and maximum mouth opening was observed after the first month. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e1-e7)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wear resistance of denture teeth is important to the longevity of removable prostheses of edentulous patients. The ability of denture teeth to maintain a stable occlusal relationship over time may be influenced by this property. The purpose of this in vitro study was to evaluate the wear resistance of polymethyl methacrylate (PMMA) denture teeth based on their chemical composition when opposed by a ceramic antagonist. The maxillary canines (n=10) of 3 PMMA denture teeth (Trubyte Biotone, cross-linked PMMA; Trilux, highly cross-linked IPN (interpenetrating polymer network)-PMMA; and Vivodent, highly cross-linked PMMA) were secured in an in vitro 2-body wear-testing apparatus that produced sliding contact of the specimens (4.5 cycles/s, sliding distance of 20 mm, under 37°C running water) against glazed or airborne particle abraded ceramic. Wear resistance was measured as height loss (mm) under 300 g (sliding force) after 100,000 cycles, using a digital measuring microscope. Mean values were analyzed by 2-way ANOVA and Tukey's test (a=0.05). The wear of Trubyte Biotone (0.93 ± 0.14 mm) was significantly higher than that of both other types of teeth tested against abraded ceramic (p<0.05). The Vivodent tooth (0.64 ± 0.17 mm) exhibited the best wear resistance among the denture teeth tested against airborne particle abraded ceramic. There were no statistically significant differences (p>0.05) in wear among the 3 denture teeth evaluated against glazed ceramic. Trilux and Vivodent teeth tested against either glazed or airborne particle abraded ceramic did not differ significantly from each other (p<0.05). All teeth showed significantly more wear against airborne particle abraded ceramic than against glazed ceramic (p<0.05). In conclusion, the three types of PMMA denture teeth presented significantly different wear resistance against the abraded ceramic. The high-strength PMMA denture teeth were more wear-resistant than the conventional PMMA denture tooth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the retention force of T-bar clasps made from commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) alloy by the insertion/removal test simulating 5 years use. Thirty-six frameworks were cast from CP Ti (n=18) and Co-Cr alloy (n=18) with identical prefabricated patterns on refractory casts from a distal extension mandibular hemi-arch segment. The castings were made on a vacuum-pressure machine, under vacuum and argon atmosphere. Each group was subdivided in three, corresponding to 0.25 mm, 0.50 mm and 0.75 mm undercuts, respectively. No polishing procedures were performed to ensure uniformity. The specimens were subjected to an insertion/removal test and data was analyzed statistically to compare CP Ti and Co-Cr alloy in the same undercut (Student's t-test for independent samples) and each material in different undercuts (one-way ANOVA) (p=0.05). Comparisons between materials revealed significant differences (p=0.017) only for the 0.50-mm undercut. No significant differences (p>0.05) were found when comparing the same material for the undercuts. It may be concluded that for different undercuts, both Co-Cr alloy and CP Ti had no significant differences for T-bar clasps; CP Ti showed the lowest retention force values when compared to Co-Cr alloy in each undercut, but with significant difference only for the 0.50-mm undercut; and both materials maintained the retentive capacity during the simulation test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The signs and symptoms of temporomandibular dysfunction (TMD) may contribute to reduce bite force and muscular activity. The aims of this study were to compare bite force in complete denture wearers with TMD (TMD group) and without TMD (healthy group).The TMD group consisted of 9 individuals, who had worn a maxillary and a mandibular complete removable denture for more than 10 years. The healthy group consisted of 9 participants who wore dentures and had satisfactory interocclusal and maxillomandibular relationship. Helkimo Index was used to analyze the dysfunction level. Maximum bite force was measured using a digital dynamometer with capacity of 100 kgf and adapted to oral conditions.The TMD group presented smaller mean bite force values than the healthy group, though without statistical significance (p>0.05). This outcome suggests that the TMD signs and symptoms and the structural conditions of the dentures did not affect the maximal bite force of complete denture wearers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Composite resins might be susceptible to degradation and staining when in contact with some foods and drinks. This study evaluated color alteration and changes in microhardness of a microhybrid composite after immersion in different colored foods and determined whether there was a correlation between these two variables. Eighty composite disks were randomly divided into 8 experimental groups (n = 10): kept dry; deionized water; orange juice; passion fruit juice; grape juice; ketchup; mustard and soy sauce. The disks were individually immersed in their respective test substance at 37 ºC, for a period of 28 days. Superficial analysis of the disk specimens was performed by taking microhardness measurements (Vickers, 50 g load for 45 seconds) and color alterations were determined with a spectrophotometer (CINTRA 10- using a CIEL*a*b* system, 400-700 nm wavelength, illuminant d65 and standard observer of 2º) at the following times: baseline (before immersion), 1, 7, 14, 21 and 28 days. Results were analyzed by ANOVA and Tukey's test (p < 0.05). Both variables were also submitted to Pearson's correlation test (p < 0.05). The passion fruit group underwent the greatest microhardness change, while the mustard group suffered the greatest color alteration. Significant positive correlation was found between the two variables for the groups deionized water, grape juice, soy sauce and ketchup. Not all color alteration could be associated with surface degradation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar a distribuição de tensões na resina em contato com os filetes de roscas de mini-implantes cilíndricos e cônicos, submetidos à carga lateral e torção de inserção. Um modelo fotoelástico foi confeccionado com gelatina transparente, para simular o osso alveolar. O modelo foi observado com um polariscópio plano e fotografado antes e após a ativação dos mini-implantes com força lateral e de inserção. A aplicação de cargas laterais provocou momentos fletores nos mini-implantes, aparecimento de franjas isocromáticas ao longo dos filetes do corpo dos mini-implantes e no ápice. Quando foi aplicado o torque de inserção, verificou-se a concentração de tensões próxima ao ápice. Concluiu-se que: (1) o mini-implante cilíndrico apresentou maior concentração de tensões no ápice, e (2) o mini-implante cônico apresentou maior concentração de tensões nos filetes de rosca apicais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study how the crossover exponent, phi, between the directed percolation (DP) and compact directed percolation (CDP) behaves as a function of the diffusion rate in a model that generalizes the contact process. Our conclusions are based in results pointed by perturbative series expansions and numerical simulations, and are consistent with a value phi = 2 for finite diffusion rates and phi = 1 in the limit of infinite diffusion rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study cellulose acetate butyrate (CAB) and carboxymehtylcellulose acetate butyrate (CMCAB) films adsorbed onto silicon wafers were characterized by means of ellipsometry, atomic force microscopy (AFM), sum frequency generation spectroscopy (SFG) and contact angle measurements. The adsorption behavior of lysozyme (LIS) or bovine serum albumin (BSA) onto CAB and CMCAB films was investigated. The amounts of adsorbed LIS or BSA onto CMCAB films were more pronounced than those onto CAB films due to the presence of carboxymethyl group in the CMCAB structure. Besides, the adsorption of BSA molecules on CMCAB films was more favored than that of LIS molecules. Antimicrobial effect of LIS bound to CAB or CMCAB layers was evaluated using Micrococcus luteus as substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We explored possible effects of negative covariation among finger forces in multifinger accurate force production tasks on the classical Fitts's speed-accuracy trade-off. Healthy subjects performed cyclic force changes between pairs of targets ""as quickly and accurately as possible."" Tasks with two force amplitudes and six ratics of force amplitude to target size were performed by each of the four fingers of the right hand and four finger combinations. There was a close to linear relation between movement time and the log-transformed ratio of target amplitude to target size across all finger combinations. There was a close to linear relation between standard deviation of force amplitude and movement time. There were no differences between the performance of either of the two ""radial"" fingers (index and middle) and the multifinger tasks. The ""ulnar"" fingers (little and ring) showed higher indices of variability and longer movement times as compared with both ""radial"" fingers and multifinger combinations. We conclude that potential effects of the negative covariation and also of the task-sharing across a set of fingers are counterbalanced by an increase in individual finger force variability in multifinger tasks as compared with single-finger tasks. The results speak in favor of a feed-forward model of multifinger synergies. They corroborate a hypothesis that multifinger synergies are created not to improve overall accuracy, but to allow the system larger flexibility, for example to deal with unexpected perturbations and concomitant tasks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim of this study was to analyse contact endoscopy as an auxiliary method for identifying parathyroid glands during thyroid surgery and to identify other variables that may interfere with this correlation. overall, 125 patients underwent thyroid surgery between January 2004 and February 2006. The variables analysed were: the total duration of surgery; time taken to locate and identify parathyroid glands; improvement in identifying these; numbers of parathyroid glands located by the surgeon and confirmed by contact endoscopy; histopathological diagnosis; presence of thyroiditis; thyroid weight; number of parathyroid glands left in thyroid specimens; and number of parathyroid gland autotransplantations. A total of 331 parathyroid glands were observed by the surgeon. however, 282 glands were identified by contact endoscopy. nine parathyroid glands (7.2%) were observed together with thyroid specimens (Kappa = 0.534). The longer the total duration of surgery (p = 0.03) and time taken to locate and identify (p = 0.00) the parathyroid glands by contact endoscopy, the lower the observed agreement. The second year of performing contact endoscopy led to better agreement between the results (p = 0.02). in conclusion, contact endoscopy is an efficient auxiliary method for identifying parathyroid glands during thyroid surgery. During the period studied, association between total duration of surgery and time taken to locate and identify parathyroid glands was statistically significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Tuberculosis clusters in families may be due to increased household exposure, shared genetic factors, or both. Household contact studies are useful to control exposure because socioeconomic and environmental conditions are similar to all subjects, allowing the evaluation of the contribution of relatedness to disease development. Methods In this study, the familial aggregation of tuberculosis using relatedness and a specific inherited marker (HLA-DRB1) was evaluated. Fifty families, which had at least two cases of tuberculosis diagnosed within the past 5 years, were selected from a cohort of tuberculosis carried out in Recife, Brazil. The first case diagnosed was considered to be a primary case. The secondary attack rate of tuberculosis in household contacts was estimated according to the degree of relatedness. The relative risk of having tuberculosis based on the degree of relatedness household and the population attributable fraction to relatedness were also estimated. HLA-DRB1 typing and attributable etiologic/preventive fractions were calculated among sick and healthy household contacts. Results Compared to unrelated contacts, the relative risk for tuberculosis adjusted for age was 1.38 (95% CI 0.86 to 2.21). Relatedness contributed 23% to the development of tuberculosis at the population levels. The HLA-DRB1*04 allele group (OR = 2.44; p =0.0324; etiologic fraction =0.15) was overrepresented and the DRB1*15 allele group (OR=0.48; p=0.0488; protective fraction=0.19) was underrepresented among household contacts exhibiting tuberculosis. The presence of DRB1 shared alleles between primary cases and their contacts was a risk factor for tuberculosis (p=0.0281). Conclusion This household contact model together with the utilisation of two genetic variables permitted the evaluation of genetic factors contributing towards tuberculosis development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine if the magnitude of the force used to induce incisor tooth movement promotes distinct activation in cells in the central amygdala (CEA) and lateral hypothalamus (LH) of rats. Also, the effect of morphine on Fos immunoreactivity (Fos-IR) was investigated in these nuclei. Materials and Methods: Adult male rats were anesthetized and divided into six groups: only anesthetized (control), without orthodontic appliance (OA), OA but without force, OA activated with 30g or 70g, OA with 70g in animals pretreated with morphine (2 mg/kg, intraperitoneal). Three hours after the onset of the experiment the rats were reanesthetized and perfused with 4% paraformaldehyde. The brains were removed and fixed, and sections containing CEA and LH were processed for Fos protein immunohistochemistry. Results: The results show that in the control group, the intramuscular injection of a ketamine/xylazine mixture did not induce Fos-IR cells in the CEA or in the LH. Again, the without force group showed a little Fos-IR. However, in the 70g group the Fos-IR was the biggest observed (P < .05, Tukey) in the CEA and LH compared with the other groups. In the 30g group, the Fos-IR did not differ from the control group, the without OA group, and the without force group. Furthermore, pretreatment with morphine in the 70g group reduced Fos-IR in these regions. Conclusions: Tooth movement promotes Fos-IR in the CEA and LH according to the magnitude of the force applied. (Angle Orthod. 2010;80:111-115.)