81 resultados para Welding automation portal

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the shear bond strength between commercially pure titanium, with and without laser welding, after airbone-particle abrasion (Al2O3) and 2 indirect composites. Sixty-four specimens were cast and divided into 2 groups with and without laser welding. Each group was divided in 4 subgroups, related to Al2O3 grain size: A - 250 µm; B - 180 µm; C- 110 µm; and D - 50 µm. Composite rings were formed around the rods and light polymerized using UniXS unit. Specimens were invested and their shear bond strength at failure was measured with a universal testing machine at a crosshead speed of 2.0 mm/min. Statistical analysis was carried out with ANOVA and Tukey's test (α=0.05). The highest bond strength means were recorded in 250 µm group without laser welding. The lowest shear bond strength means were recorded in 50 µm group with laser welding. Statistically significant differences (p<0.05) were found between all groups. In conclusion, airborne particle abrasion yielded significantly lower bond strength as the Al2O3 particle size decreased. Shear bond strength decreased in the laser welded specimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power distribution automation and control are import-ant tools in the current restructured electricity markets. Unfortunately, due to its stochastic nature, distribution systems faults are hardly avoidable. This paper proposes a novel fault diagnosis scheme for power distribution systems, composed by three different processes: fault detection and classification, fault location, and fault section determination. The fault detection and classification technique is wavelet based. The fault-location technique is impedance based and uses local voltage and current fundamental phasors. The fault section determination method is artificial neural network based and uses the local current and voltage signals to estimate the faulted section. The proposed hybrid scheme was validated through Alternate Transient Program/Electromagentic Transients Program simulations and was implemented as embedded software. It is currently used as a fault diagnosis tool in a Southern Brazilian power distribution company.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Petri net (PN) modeling is one of the most used formal methods in the automation applications field, together with programmable logic controllers (PLCs). Therefore, the creation of a modeling methodology for PNs compatible with the IEC61131 standard is a necessity of automation specialists. Different works dealing with this subject have been carried out; they are presented in the first part of this paper [Frey (2000a, 2000b); Peng and Zhou (IEEE Trans Syst Man Cybern, Part C Appl Rev 34(4):523-531, 2004); Uzam and Jones (Int J Adv Manuf Technol 14(10):716-728, 1998)], but they do not present a completely compatible methodology with this standard. At the same time, they do not maintain the simplicity required for such applications, nor the use of all-graphical and all-mathematical ordinary Petri net (OPN) tools to facilitate model verification and validation. The proposal presented here completes these requirements. Educational applications at the USP and UEA (Brazil) and the UO (Cuba), as well as industrial applications in Brazil and Cuba, have already been carried out with good results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Extrahepatic portal vein thrombosis (EHPVT) is an important cause of portal hypertension in children. Rex shunt has been used successfully to treat these patients. Methods: We report our experience in 19 infants and children (5 months to 14 years) with HPVT eligible for a mesenteric-portal surgical shunt with left internal jugular vein autograft. Eight children had idiopathic EHPVT, nine had post-umbilical catheterization EHPVT, one had portal vein agenesis, and one had posttransplant EHPVT. Results: It was possible to perform the Rex shunt in all patients except for 8 of 9 cases in the post-umbilical catheterization EHPVT group. A Warren procedure was performed in 4 of those patients and a proximal splenorenal shunt in 1. Current follow-up ranges from 3 to 26 months. Shunt thrombosis occurred in one patient with portal vein agenesis and associated cardiac anomaly. Portal hypertension has significantly improved after surgery. None of our patients have experienced new bleeding episodes until now. Conclusions: The Rex shunt should be considered in the treatment of children with idiopathic EHPVT experiencing repeated gastrointestinal bleeding episodes refractory to endoscopic treatment. Nevertheless, the role of this operation for children with post-umbilical catheterization EHPVT is yet to be clearly evaluated. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Aim: Although prophylaxis with beta-blockers has been shown to decrease variceal pressure and wall tension in cirrhotic patients, this has not been demonstrated in non-cirrhotic portal hypertension caused by Schistosoma mansoni infection. Methods: Thirteen patients without history of previous gastrointestinal bleeding were included. All of them had high-risk esophageal varices at endoscopy. An endoscopic gauge and a high-frequency endoscopic ultrasonography miniprobe were used to assess transmural variceal pressure and wall tension before and after achieving beta-blockade with propranolol. Results: Baseline variceal pressure decreased from 13.3 +/- 3.5 to 8.2 +/- 2.0 mmHg (P < 0.0001) and wall tension from 500.2 +/- 279.8 to 274.0 +/- 108.3 mg.mm-1. The overall effect of propranolol on decreasing variceal pressure and wall tension expressed in percentage change in relation to baseline values was 35.7 +/- 18.4% and 35.9 +/- 26.7%, respectively (P = 0.9993). Conclusion: Propranolol significantly reduced variceal pressure and wall tension in schistosomiasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Endoscopic sclerotherapy (ES) has been the standard treatment for children with idiopathic extrahepatic portal vein obstruction (EHPVO). Portosystemic shunts are indicated when variceal bleeding cannot be controlled by ES. Recently, mesenteric left portal vein bypass was indicated as a surgical intervention and preventative measure for hepatic dysfunction in children with long-term EHPVO. Nevertheless, there is a lack Of published data confirming the extent of hepatic dysfunction, hypersplenism, and physical development in children with long-term follow-up. Method: We retrospectively verified the long-term outcomes in 82 children with EHPVO treated with ES protocol, focusing on mortality, control of bleeding, hypersplenism, and consequent hepatic dysfunction. Results: Of the children, 56% were free from bleeding after the initiation of ES. The most frequent cause of rebleeding was gastric varices (30%). Four patients had recurrent bleeding from esophageal varices (4.6%). Four patients underwent surgery as a consequence of uncontrolled gastric varices. There were no deaths. Most patients showed good physical development. We observed a mild but statistically significant drop in factor V motion, as well as leukocyte and platelet count. Conclusion: Endoscopic sclerotherapy is an efficient treatment for children with EHPVO. The incidence of rebleeding is low, and there was no mortality. Children develop mild liver dysfunction and hypersplenism with long-term follow-up. Only a few patients manifest symptoms of hypersplenism, portal biliopathy, or liver dysfunction before adolescence. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper has the objective to evaluate retrospectively the long-term results of transhepatic treatment of PV stenoses after pediatric LT. During an eight-yr period, 15 children with PV stenoses underwent PTA with balloon dilation or stent placement in case of PTA failure after LT. Patients` body weights ranged from 9.3 to 46 kg (mean, 15.5 kg). PV patency was evaluated in the balloon dilation and in the stent placement groups. Technical and clinical successes were achieved in all cases with no complication. Eleven patients (11/15; 73.3%) were successfully treated by single balloon dilation. Four patients (4/15; 26.7%) needed stent placement. One patient was submitted to stent placement during the same procedure because of PTA failure. The other three developed clinical signs of portal hypertension because of PV restenoses two, eight, and twenty-eight months after the first PTA. They had to be submitted to a new procedure with stent placement. The follow-up time ranged from 3 to 8.1 yr (mean, 6.3 yr). In conclusion, transhepatic treatment of PV stenoses after pediatric LT with balloon dilation or stent placement demonstrated to be a safe and effective treatment that results in long-term patency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Many chronic liver diseases lead to progressive hepatic fibrosis, a condition that can ultimately result in loss of organ function and severe portal hypertension necessitating hepatic transplantation. Within the last few decades, studies have been conducted to demonstrate the possibility of drug modulation of hepatic fibrogenesis. Regarding biliary obstruction, it has been suggested that administration of corticosteroids could promote better late outcomes for children with biliary atresia submitted to Kasai`s portoenterostomy. Models used to test potential antifibrogenic drugs such as pentoxifylline (PTX) have not included growing animals. Methods: In this experimental study, 119 young rats (21st or 22nd days) were submitted to laparotomy and common bile duct ligation (CBDL) or to sham surgery (SHAM). Animals were allocated into 5 groups, according to surgical procedure, and administered the following solutions: (1) CBDL + distilled water, (2) SHAM + distilled water, (3) CBDL + PTX, (4) CBDL + prednisolone (PRED), and (5) CBDL + PTX + PRED (PTX + PRED). Each group was further divided into 2 subgroups according to the length of the experiment (15 or 30 days). At the end of the defined period, animals were weighed, and a hepatic fragment was collected from each one for analyses. Results: The PTX animals exhibited increased weight gain compared to animals in the PRED or PTX + PRED groups. Animals from the 3 therapeutic groups (PTX, PRED, and PTX + PRED) showed diminished collagen-filled area in portal spaces. Total portal space area was increased in the PTX group. Conclusions: Hepatic fibrosis induced by bile duct ligation in young rats could be modulated by pharmacologic interventions. Administration of PTX or PRED, or the combination of both, resulted in diminished collagen-filled areas in portal spaces. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Purpose. Posttransplantation portal vein thrombosis (PVT) can have severe health consequences, and portal hypertension and other consequences of the long-term privation of portal inflow to the graft may be hazardous, especially in young children. The Rex shunt has been used successfully to treat PVT patients since 1998. In 2007, we started to perform this surgery in patients with idiopathic PVT and late posttransplantation PVT. Herein we have reported our experience with this technique in acute posttransplantation PVT. Methods. Three patients of ages 12, 15, and 18 months underwent cadaveric (n = 1) or living donor (n = 2) orthotopic liver transplantation (OLT). All patients had biliary atresia with portal vein hypoplasia; they developed acute PVT on the first postoperative day. They underwent a mesenteric-portal surgical shunt (Rex shunt) using a left internal jugular vein autograft (n = 2) or cadaveric iliac vein graft (n = 1) on the first postoperative day. Results. The 8-month follow-up has confirmed shunt patency by postoperative Doppler ultrasound. There have been no biliary complications to date. Conclusions. The mesenteric-portal shunt (Rex shunt) using an autograft of the left internal jugular or a cadaveric vein graft should be considered for children with acute PVT after OLT. These children usually have small portal veins; reanastomosis is often unsuccessful. In addition, this technique has the advantage to avoid manipulation of the hepatic hilum and biliary anastomosis. Although this study was based on a limited experience, we concluded that this technique is feasible, with great benefits to and low risks for these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Absence of the horizontal segment of the left portal vein (PV) or absence of bifurcation of the portal vein (ABPV) is extremely rare anomaly. The aim of this study was to study the extra-hepatic PV demonstrating the importance of its careful assessment for the purpose of split-liver transplantation. Human cadaver livers (n = 60) were obtained from routine autopsies. The cutting plane of the liver consisted of a longitudinal section made immediately on the left of the supra-hepatic inferior vena cava through the gallbladder bed preserving the arterial, portal and biliary branches in order to obtain two viable grafts (right lobe-segments V, VI, VII, and VIII and left lobe-segments II, III, and IV) as defined by the main portal scissure. The PV was dissected out and recorded for application of the liver splitting. The PV trunk has been divided into right and left branch in 50 (83.3%) cases. A trifurcation of the PV was found in 9 (15.2%) cases, 3 (5%) was a right anterior segmental PV arising from the left PV and 6 (10%) a right posterior segmental PV arising from the main PV. ABPV occurred in 1 (1.6%) case. Absence of bifurcation of the portal vein is a rare anatomic variation, the surgeon must be cautious and aware of the existence of this exceptional PV anomaly either pre or intra-operatively for the purpose of hepatectomies or even split-liver transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose. Late portal vein thrombosis (PVT) can be extremely well tolerated, although portal hypertension and other consequences of the long-term deprivation of portal inflow to the graft may be hazardous, especially in young children. Recently, the ""Rex shunt"" has been used successfully to treat these patients. We now report the initial experience with this novel technique. Methods. A 3-year-old girl with PVT at 7 months after whole organ cadaveric liver transplant displayed portal hypertension with an episode of gastrointestinal bleeding, requiring a mesenteric-portal surgical shunt (""Rex shunt"") using a left internal jugular vein autograft. Results. Upon current follow-up of 6 months, postoperative Doppler ultrasound confirmed shunt patency. Endoscopic status was significantly improved after surgery with resolution of portal hypertension. There was no recurrence of bleeding. Conclusions. The mesenteric-portal shunt (""Rex shunt""), using a left internal jugular vein autograft, should be considered for children with late PVT after liver transplantation. Although this is an initial experience, we may conclude that this technique is feasible, with great potential benefits and low risks for these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a 2-year-old child with extrahepatic portal venous obstruction, hepatoportal sclerosis and pulmonary thromboembolism whose sole hypercoagulability factor was the presence of anti-phospholipid antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare the accuracy of fit of three types of implant-supported frameworks cast in Ni-Cr alloy: specifically, a framework cast as one piece compared to frameworks cast separately in sections to the transverse or the diagonal axis, and later laser welded. Materials and Methods: Three sets of similar implant-supported frameworks were constructed. The first group of six 3-unit implant-supported frameworks were cast as one piece, the second group of six were sectioned in the transverse axis of the pontic region prior to casting, and the last group of six were sectioned in the diagonal axis of the pontic region prior to casting. The sectioned frameworks were positioned in the matrix (10 N(.)cm torque) and laser welded. To evaluate passive fit, readings were made with an optical microscope with both screws tightened and with only one-screw tightened. Data were submitted to ANOVA and Tukey-Kramer`s test (p < 0.05). Results: When both screws were tightened, no differences were found between the three groups (p > 0.05). In the single-screw-tightened test, with readings made opposite to the tightened side, the group cast as one piece (57.02 +/- 33.48 mu m) was significantly different (p < 0.05) from the group sectioned diagonally (18.92 +/- 4.75 mu m) but no different (p > 0.05) from the group transversally sectioned (31.42 +/- 20.68 mu m). On the tightened side, no significant differences were found between the groups (p > 0.05). Conclusions: Results of this study showed that casting diagonally sectioned frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves the levels of passivity to the same frameworks when compared to structures cast as one piece.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the vertical misfit of 3-unit implant-supported nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloy and commercially pure titanium (cpTi) frameworks after casting as 1 piece, after sectioning and laser welding, and after simulated porcelain firings. The results on the tightened side showed no statistically significant differences. On the opposite side, statistically significant differences were found for Co-Cr alloy (118.64 mu m [SD: 91.48] to 39.90 mu m [SD: 27.13]) and cpTi (118.56 mu m [51.35] to 27.87 mu m [12.71]) when comparing 1-piece to laser-welded frameworks. With both sides tightened, only Co-Cr alloy showed statistically significant differences after laser welding. Ni-Cr alloy showed the lowest misfit values, though the differences were not statistically significantly different. Simulated porcelain firings revealed no significant differences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58 center dot 66 +/- 14 center dot 30 mu m) was significantly different from cp Ti group after diagonal section (IV: 27 center dot 51 +/- 8 center dot 28 mu m) (P < 0 center dot 05). On the tightened side, no significant differences were found between groups (P > 0 center dot 05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.