59 resultados para Voice detectors
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
This Letter reports new results from the MINOS experiment based on a two-year exposure to muon neutrinos from the Fermilab NuMI beam. Our data are consistent with quantum-mechanical oscillations of neutrino flavor with mass splitting vertical bar Delta m(2)vertical bar = (2.43 +/- 0.13) x 10(-3) eV(2) (68% C.L.) and mixing angle sin(2)(2 theta) > 0.90 (90% C.L.). Our data disfavor two alternative explanations for the disappearance of neutrinos in flight: namely, neutrino decays into lighter particles and quantum decoherence of neutrinos, at the 3.7 and 5.7 standard-deviation levels, respectively.
Resumo:
Research Foundation of the State of Sao Paulo (FAPESP)
Resumo:
State of Sao Paulo Research Foundation (FAPESP)
Resumo:
This paper analyzes the complexity-performance trade-off of several heuristic near-optimum multiuser detection (MuD) approaches applied to the uplink of synchronous single/multiple-input multiple-output multicarrier code division multiple access (S/MIMO MC-CDMA) systems. Genetic algorithm (GA), short term tabu search (STTS) and reactive tabu search (RTS), simulated annealing (SA), particle swarm optimization (PSO), and 1-opt local search (1-LS) heuristic multiuser detection algorithms (Heur-MuDs) are analyzed in details, using a single-objective antenna-diversity-aided optimization approach. Monte- Carlo simulations show that, after convergence, the performances reached by all near-optimum Heur-MuDs are similar. However, the computational complexities may differ substantially, depending on the system operation conditions. Their complexities are carefully analyzed in order to obtain a general complexity-performance framework comparison and to show that unitary Hamming distance search MuD (uH-ds) approaches (1-LS, SA, RTS and STTS) reach the best convergence rates, and among them, the 1-LS-MuD provides the best trade-off between implementation complexity and bit error rate (BER) performance.
Resumo:
Morbid obesity is highly prevalent in the Western World, and its consequences present a real public health challenge. Voice alterations can represent one of these consequences and represent an opportunity for interference with therapeutic methods. This particularly features of the individual`s voice was the goal of the present study. A group of 45 adult volunteers of both sexes with a BMI greater than 35 Kg/m(2) was selected among patients of the Obesity Ambulatory of the Digestive Surgery Division. The control group consisted of volunteers matched by sex, age (+/- 1 year), and smoking habits, but with a BMI bellow 30 Kg/m(2). All subjects were submitted to laryngoscopic examination, audio perceptive analysis, and voice acoustics determination. Examinations were always performed by the same doctor, and diagnoses were provided by two different physician specialists in laryngology and voice. Obese individuals exhibit the following modifications in voice feature: hoarseness, murmuring, vocal instability, altered jitter and shimmer, and reduced maximum phonation times as well the presence of voice strangulation at the end of emission. The voices of individuals with morbid obesity are different of the voice of nonobese people and demonstrate significant changes in vocal characteristics.
Resumo:
The metallic voice is usually confused with ring or nasality by singers and nontrained listeners. who are not used to perceptual vocal analysis. They believe a metallic voice results from a rise in fundamental frequency. A diagnostic error in this aspect may lead to lowering pitch, an incorrect procedure that Could Cause vocal overload and fatigue. The purpose of this article is to Study the quality of metallic voice considering the correlation between information of the physiological and acoustic plans, based on a perceptive consensual assumption. Fiberscopic video pharyngolaryngoscopy was performed on 21 professional singers while speaking vowel [e]-in normal and metallic modes to observe muscular movements and structural changes of the velopharynx, pharynx, and larynx. Vocal samples captured simultaneously to the fiberscopic examination were acoustically analyzed. Frequency and amplitude of the first four formants (F(1), F(2), F(3), and F(4)) were extracted by means of linear predictor coefficients (LPC) Spectrum and were statistically analyzed. Vocal tract adjustments such as velar lowering, pharyngeal wall narrowing, laryngeal rise, aryepiglottic, and lateral laryngeal constrictions were frequently found: there were no significant changes in frequency and amplitude of F(1) in the metallic voiced there were significant increases in amplitudes of F(2), F(3), and F(4) and in frequency for F, metallic Voice perceived as louder was correlated to an increase ill amplitude of F(3) and F(4). Physiological adjustments of velopharynx, pharynx, and larynx are combined in characterizing the metallic voice and can be acoustically related to changes in formant pattern.
Resumo:
The objectives of this study were to check music and voice message influence on vital signs and facial expressions of patients with disorders of consciousness and to connect the existence of patient`s responses with the Glasgow Coma Scale or with the Ramsay Sedation Scale. The method was a single-blinded randomized controlled clinical trial with 30 patients, from two intensive care units, being divided into two groups (control and experimental). Their relatives recorded a voice message and chose a song according to the patient`s preference. The patients were submitted to three sessions for three consecutive days. Significant statistical alterations of the vital signs were noted during the message playback (oxygen saturation-Day 1 and Day 3; respiratory frequency-Day 3) and with facial expression, on Day 1, during both music and message. The conclusion was that the voice message was a stronger stimulus than the music.
Resumo:
Considering that orthognathic surgery promotes changes in orofacial structures constituting the resonating system, functional changes secondary to surgery are expected to affect speech, leading to the need for further speech and voice adjustments. Thus, understanding the possible relationships of these structures with voice production is important. Therefore, this Study aimed to describe the changes in voice fundamental frequency of a patient submitted to orthognathic surgery and observe if there is a relationship with hyoid bone positioning at the different treatment periods. The results revealed that voice fundamental frequency increased after surgery, returning to values close to the preoperative condition, which corresponded to vertical movement of the hyoid bone.
Resumo:
The triple- and quadruple-escape peaks of 6.128 MeV photons from the (19)F(p,alpha gamma)(16)O nuclear reaction were observed in an HPGe detector. The experimental peak areas, measured in spectra projected with a restriction function that allows quantitative comparison of data from different multiplicities, are in reasonably good agreement with those predicted by Monte Carlo simulations done with the general-purpose radiation-transport code PENELOPE. The behaviour of the escape intensities was simulated for some gamma-ray energies and detector dimensions; the results obtained can be extended to other energies using an empirical function and statistical properties related to the phenomenon. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
This paper proposes an improved voice activity detection (VAD) algorithm using wavelet and support vector machine (SVM) for European Telecommunication Standards Institution (ETS1) adaptive multi-rate (AMR) narrow-band (NB) and wide-band (WB) speech codecs. First, based on the wavelet transform, the original IIR filter bank and pitch/tone detector are implemented, respectively, via the wavelet filter bank and the wavelet-based pitch/tone detection algorithm. The wavelet filter bank can divide input speech signal into several frequency bands so that the signal power level at each sub-band can be calculated. In addition, the background noise level can be estimated in each sub-band by using the wavelet de-noising method. The wavelet filter bank is also derived to detect correlated complex signals like music. Then the proposed algorithm can apply SVM to train an optimized non-linear VAD decision rule involving the sub-band power, noise level, pitch period, tone flag, and complex signals warning flag of input speech signals. By the use of the trained SVM, the proposed VAD algorithm can produce more accurate detection results. Various experimental results carried out from the Aurora speech database with different noise conditions show that the proposed algorithm gives considerable VAD performances superior to the AMR-NB VAD Options 1 and 2, and AMR-WB VAD. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Nowadays, noninvasive methods of diagnosis have increased due to demands of the population that requires fast, simple and painless exams. These methods have become possible because of the growth of technology that provides the necessary means of collecting and processing signals. New methods of analysis have been developed to understand the complexity of voice signals, such as nonlinear dynamics aiming at the exploration of voice signals dynamic nature. The purpose of this paper is to characterize healthy and pathological voice signals with the aid of relative entropy measures. Phase space reconstruction technique is also used as a way to select interesting regions of the signals. Three groups of samples were used, one from healthy individuals and the other two from people with nodule in the vocal fold and Reinke`s edema. All of them are recordings of sustained vowel /a/ from Brazilian Portuguese. The paper shows that nonlinear dynamical methods seem to be a suitable technique for voice signal analysis, due to the chaotic component of the human voice. Relative entropy is well suited due to its sensibility to uncertainties, since the pathologies are characterized by an increase in the signal complexity and unpredictability. The results showed that the pathological groups had higher entropy values in accordance with other vocal acoustic parameters presented. This suggests that these techniques may improve and complement the recent voice analysis methods available for clinicians. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
The present paper describes the utilization of nickel hydroxide modified electrodes toward the catalytic oxidation of carbohydrates (glucose, fructose, lactose and sucrose) and their utilization as electrochemical sensor. The modified electrodes were employed as a detector in flow injection analysis for individual carbohydrate detection, and to an ionic column chromatography system for multi-analyte samples aiming a prior separation step. Kinetic studies were performed on a rotating disk electrode (RDE) in order to determine both the heterogeneous rate constant and number of electrons transferred for each carbohydrate. Many advantages were found for the proposed system including fast and easy handling of the electrode modification, low cost procedure, a wide range of linearity (0.5-50 ppm), low detection limits (ppb level) and high sensitivities. (C) 2009 Elsevier B.V. All rights reserved.