215 resultados para Visual performance

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye aft er the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients aft er bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at I and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (Am J Ophthalmol 2010;149:383-389. (C) 2010 by Elsevier Inc. All rights reserved.)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Patients with early age-related maculopathy ( ARM) do not necessarily show obvious morphological signs or functional impairment. Many have good visual acuity, yet complain of decreased visual performance. The aim of this study was to investigate the aging effects on performance of parafoveal letter recognition at reduced contrast, and defects caused by early ARM and normal fellow eyes of patients with unilateral age-related macular degeneration (nfAMD). Methods Testing of the central visual field (8 radius) was performed by the Macular Mapping Test (MMT) using recognition of letters in 40 parafoveal target locations at four contrast levels (5, 10, 25 and 100%). Effects of aging were investigated in 64 healthy subjects aged 23 to 76 years (CTRL). In addition, 39 eyes (minimum visual acuity of 0.63; 20/30) from 39 patients with either no visible signs of ARM, while the fellow eye had advanced age-related macular degeneration (nfAMD; n=12), or early signs of ARM (eARM; n=27) were examined. Performance was expressed summarily as a ""field score"" (FS). Results Performance in the MMT begins to decline linearly with age in normal subjects from the age of 50 and 54 years on, at 5% and 10% contrast respectively. The differentiation between patients and CTRLs was enhanced if FS at 5% was analyzed along with FS at 10% contrast. In 8/12 patients from group nfAMD and in 18/27 from group eARM, the FS was statistically significantly lower than in the CTRL group in at least one of the lower contrast levels. Conclusion Using parafoveal test locations, a recognition task and diminished contrast increases the chance of early detection of functional defects due to eARM or nfAMD and can differentiate them from those due to aging alone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bee males (drones) of stingless bees tend to congregate near entrances of conspecific nests, where they wait for virgin queens that initiate their nuptial flight. We observed that the Neotropical solitary wasp Trachypus boharti (Hymenoptera, Cabronidae) specifically preys on males of the stingless bee Scaptotrigona postica (Hymenoptera, Apidae); these wasps captured up to 50 males per day near the entrance of a single hive. Over 90% of the wasp attacks were unsuccessful; such erroneous attacks often involved conspecific wasps and worker bees. After the capture of non-male prey, wasps almost immediately released these individuals unharmed and continued hunting. A simple behavioral experiment showed that at short distances wasps were not specifically attracted to S. postica males nor were they repelled by workers of the same species. Likely, short-range prey detection near the bees' nest is achieved mainly by vision whereas close-range prey recognition is based principally on chemical and/or mechanical cues. We argue that the dependence on the wasp's visual perception during attack and the crowded and dynamic hunting conditions caused wasps to make many preying attempts that failed. Two wasp-density-related factors, wasp-prey distance and wasp-wasp encounters, may account for the fact that the highest male capture and unsuccessful wasp bee encounter rates occurred at intermediate wasp numbers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An inverted U-shape function between cortisol levels and memory performance has been reported in studies on both young animals and humans. Yet little is known about this relationship in normal aging or in older subjects with cognitive impairment. This issue is particularly significant since increased levels of cortisol have been reported in Alzheimer`s disease (AD). The present study examined the association between cortisol levels and visual memory performance in healthy subjects as well as in individuals presenting mild cognitive impairment (MCI) or AD. Salivary cortisol was measured in 40 healthy elderly subjects, 31 individuals with amnestic MCI, and 40 subjects with mild probable AD. Memory performance was evaluated using the Brief Cognitive Screening Battery. Higher cortisol levels were associated with better memory performance in healthy elderly (p = 0.005), while higher cortisol levels were correlated with poorer memory performance in MCI subjects (p = 0.011). No correlation between cortisol and memory was found in the AD group (p > 0.05). These results suggest that the relationship between cortisol levels and memory performance in the aging process could vary according to the presence or absence of cognitive impairment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The properties of recycled aggregate produced from mixed (masonry and concrete) construction and demolition (C&D) waste are highly variable, and this restricts the use of such aggregate in structural concrete production. The development of classification techniques capable of reducing this variability is instrumental for quality control purposes and the production of high quality C&D aggregate. This paper investigates how the classification of C&D mixed coarse aggregate according to porosity influences the mechanical performance of concrete. Concretes using a variety of C&D aggregate porosity classes and different water/cement ratios were produced and the mechanical properties measured. For concretes produced with constant volume fractions of water, cement, natural sand and coarse aggregate from recycled mixed C&D waste, the compressive strength and Young modulus are direct exponential functions of the aggregate porosity. Sink and float technique is a simple laboratory density separation tool that facilitates the separation of cement particles with lower porosity, a difficult task when done only by visual sorting. For this experiment, separation using a 2.2 kg/dmA(3) suspension produced recycled aggregate (porosity less than 17%) which yielded good performance in concrete production. Industrial gravity separators may lead to the production of high quality recycled aggregate from mixed C&D waste for structural concrete applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To compare reading ability after cataract surgery and bilateral implantation of multifocal intraocular lenses (IOLs) with a +3 00 diopter (D) addition (add) or a +4 00 D add SETTING Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil DESIGN Prospective comparative study METHODS Patients scheduled for cataract surgery were randomly assigned to bilateral implantation of an aspheric AcrySof ReSTOR multifocal IOL with a +3 00 diopter (D) addition (add) or a +4 00 D add The reading speed, critical print size, and reading acuity were measured binocularly with best correction using MNREAD acuity charts 6 months after surgery Patients were tested with the chart at the best patient-preferred reading distance and at 40 cm Binocular uncorrected and best distance-corrected visual acuities at far and near were also measured RESULTS The study enrolled 32 patients At the best reading distance the results were similar between the 2 IOL groups in all reading parameters When tested at 40 cm, reading speed at all print sizes from 03 to 00 (all P< 001), critical print size (P< 001) and reading acuity (P = 014) were statistically significantly better in the +3 00 D IOL group than in the +4 00 DIOL group Uncorrected and corrected visual acuities at far and near were similar between the 2 groups CONCLUSION Although the 2 IOL groups had similar performance in reading parameters, patients had to adjust to their best reading distance The +3 00 D IOL performed better than the +4 00 D IOL at 40 cm

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to elucidate electrophysiological and cortical mechanisms involved in anticipatory actions when 23 healthy right-handed subjects had to catch a free falling object by qEEG gamma-band (30-100 Hz). It is involved in cognitive processes, memory, spatial/temporal and proprioceptive factors. Our hypothesis is that an increase in gamma coherence in frontal areas will be observed during moment preceding ball drop, due to their involvement in attention, planning, selection of movements, preparation and voluntary control of action and in central areas during moment after ball drop, due to their involvement in motor preparation, perception and execution of movement. However, through a paired t-test, we found an increase in gamma coherence for F3-F4 electrode pair during moment preceding ball drop and confirmed our hypothesis for C3-C4 electrode pair. We conclude that gamma plays an important role in reflecting binding of several brain areas in a complex motor task as observed in our results. Moreover, for selection of movements, preparation and voluntary control of action, motor preparation, perception and execution of movement, the integration of somatosensory and visual information is mandatory. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS. One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The severity of the disease was graded based on the visual field index (VFI) from standard automated perimetry. Imaging of the retinal nerve fiber layer (RNFL) was obtained using the optic disc cube protocol available on the Cirrus HD-OCT. Pooled receiver operating characteristic (ROC) curves were initially obtained for each parameter of the Cirrus HD-OCT. The effect of disease severity on diagnostic performance was evaluated by fitting an ROC regression model, with VFI used as a covariate, and calculating the area under the ROC curve (AUCs) for different levels of disease severity. RESULTS. The largest pooled AUCs were for average thickness (0.892), inferior quadrant thickness (0.881), and superior quadrant thickness (0.874). Disease severity had a significant influence on the detection of glaucoma. For the average RNFL thickness parameter, AUCs were 0.962, 0.932, 0.886, and 0.822 for VFIs of 70%, 80%, 90%, and 100%, respectively. CONCLUSIONS. Disease severity had a significant effect on the diagnostic performance of the Cirrus HD-OCT and thus should be considered when interpreting results from this device and when considering the potential applications of this instrument for diagnosing glaucoma in the various clinical settings. (Invest Ophthalmol Vis Sci. 2010;51:4104-4109) DOI:10.1167/iovs.094716

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fear of heights, or acrophobia, is one of the most frequent subtypes of specific phobia frequently associated to depression and other anxiety disorders. Previous evidence suggests a correlation between acrophobia and abnormalities in balance control, particularly involving the use of visual information to keep postural stability. This study investigates the hypotheses that (1) abnormalities in balance control are more frequent in individuals with acrophobia even when not exposed to heights, that (2) acrophobic symptoms are associated to abnormalities in visual perception of movement; and that (3) individuals with acrophobia are more sensitive to balance-cognition interactions. Thirty-one individuals with specific phobia of heights and thirty one non-phobic controls were compared using dynamic posturography and a manual tracking task. Acrophobics had poorer performance in both tasks, especially when carried out simultaneously. Previously described interference between posture control and cognitive activity seems to play a major role in these individuals. The presence of physiologic abnormalities is compatible with the hypothesis of a non-associative acquisition of fear of heights, i.e., not associated to previous traumatic events or other learning experiences. Clinically, this preliminary study corroborates the hypothesis that vestibular physical therapy can be particularly useful in treating individuals with fear of heights.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods: 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen`s kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results: Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions: Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. Dentomaxillofacial Radiology (2010) 39, 362-367. doi: 10.1259/dmfr/22865872

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare visual inspection (VI), radiographic examination (RX) and the laser fluorescence device DIAGNOdent (L), as well as their combinations in vitro regarding treatment decisions for occlusal surfaces. Methods: 72 extracted human permanent teeth (molars and premolars) were used. Treatment decisions were recorded by three calibrated examiners, and the options available were fissure sealant and conservative restoration. For validation of treatment decisions, the teeth were sectioned and examined in a stereomicroscope. Thereafter, dental slices were scanned and the images were edited to facilitate classification of existing carious lesions. Intra and inter-examiner reproducibility for the determination of treatment plans were calculated using Cohen`s kappa test (95%-CI). Sensitivity, specificity, positive and negative predictive values, and the area under the ROC curve were also calculated. Results: VI and L provided on average the greatest intra- and inter-examiner reproducibility, respectively. Although the combination of diagnostic methods may decrease both intra- and inter examiners reproducibility, combination of VI, L and RX resulted in the greatest sensitivity, being statistically superior to RX and L. There was more inter-examiner agreement for the option of restorative treatment, while the use of sealants as a treatment option yielded the lowest values. Negative predictive values were numerically inferior to positive predictive values, indicating that the examiners preferred not to restore a carious tooth than to proceed operatively in an intact tooth. The combination of the three methods studied showed the best results in determining treatment plans for occlusal surfaces, when compared to the other types of exams. On the other hand, radiographic examination and laser fluorescence were less efficient when used alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A síndrome do X Frágil é a causa mais frequente de deficiência intelectual hereditária. A variante de Dandy-Walker trata-se de uma constelação específica de achados neurorradiológicos. Este estudo relata achados da comunicação oral e escrita de um menino de 15 anos com diagnóstico clínico e molecular da síndrome do X-Frágil e achados de neuroimagem do encéfalo compatíveis com variante de Dandy-Walker. A avaliação fonoaudiológica foi realizada por meio da Observação do Comportamento Comunicativo, aplicação do ABFW - Teste de Linguagem Infantil - Fonologia, Perfil de Habilidades Fonológicas, Teste de Desempenho Escolar, Teste Illinois de Habilidades Psicolinguísticas, avaliação do sistema estomatognático e avaliação audiológica. Observou-se: alteração de linguagem oral quanto às habilidades fonológicas, semânticas, pragmáticas e morfossintáticas; déficits nas habilidades psicolinguísticas (recepção auditiva, expressão verbal, combinação de sons, memória sequencial auditiva e visual, closura auditiva, associação auditiva e visual); e alterações morfológicas e funcionais do sistema estomatognático. Na leitura verificou-se dificuldades na decodificação dos símbolos gráficos e na escrita havia omissões, aglutinações e representações múltiplas com o uso predominante de vogais e dificuldades na organização viso-espacial. Em matemática, apesar do reconhecimento numérico, não realizou operações aritméticas. Não foram observadas alterações na avaliação audiológica periférica. A constelação de sintomas comportamentais, cognitivos, linguísticos e perceptivos, previstos na síndrome do X-Frágil, somada às alterações estruturais do sistema nervoso central, pertencentes à variante de Dandy-Walker, trouxeram interferências marcantes no desenvolvimento das habilidades comunicativas, no aprendizado da leitura e escrita e na integração social do indivíduo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study compared the accuracy of three electronic apex locators (EALs) - Elements Diagnostic®, Root ZX® and Apex DSP® - in the presence of different irrigating solutions (0.9% saline solution and 1% sodium hypochlorite). The electronic measurements were carried out by three examiners, using twenty extracted human permanent maxillary central incisors. A size 10 K file was introduced into the root canals until reaching the 0.0 mark, and was subsequently retracted to the 1.0 mark. The gold standard (GS) measurement was obtained by combining visual and radiographic methods, and was set 1 mm short of the apical foramen. Electronic length values closer to the GS (± 0.5 mm) were considered as accurate measures. Intraclass correlation coefficients (ICCs) were used to verify inter-examiner agreement. The comparison among the EALs was performed using the McNemar and Kruskal-Wallis tests (p < 0.05). The ICCs were generally high, ranging from 0.8859 to 0.9657. Similar results were observed for the percentage of electronic measurements closer to the GS obtained with the Elements Diagnostic® and the Root ZX® EALs (p > 0.05), independent of the irrigating solutions used. The measurements taken with these two EALs were more accurate than those taken with Apex DSP®, regardless of the irrigating solution used (p < 0.05). It was concluded that Elements Diagnostic® and Root ZX® apex locators are able to locate the cementum-dentine junction more precisely than Apex DSP®. The presence of irrigating solutions does not interfere with the performance of the EALs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Secondary caries has been reported as the main reason for restoration replacement. The aim of this in vitro study was to evaluate the performance of different methods - visual inspection, laser fluorescence (DIAGNOdent), radiography and tactile examination - for secondary caries detection in primary molars restored with amalgam. Fifty-four primary molars were photographed and 73 suspect sites adjacent to amalgam restorations were selected. Two examiners evaluated independently these sites using all methods. Agreement between examiners was assessed by the Kappa test. To validate the methods, a caries-detector dye was used after restoration removal. The best cut-off points for the sample were found by a Receiver Operator Characteristic (ROC) analysis, and the area under the ROC curve (Az), and the sensitivity, specificity and accuracy of the methods were calculated for enamel (D2) and dentine (D3) thresholds. These parameters were found for each method and then compared by the McNemar test. The tactile examination and visual inspection presented the highest inter-examiner agreement for the D2 and D3 thresholds, respectively. The visual inspection also showed better performance than the other methods for both thresholds (Az = 0.861 and Az = 0.841, respectively). In conclusion, the visual inspection presented the best performance for detecting enamel and dentin secondary caries in primary teeth restored with amalgam.