54 resultados para Vaginal Delivery

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The objective of this Pilot Study was to determine pain characteristics of pregnant women immediately before and after childbirth by vaginal delivery and to compare them with the pain intensity reported by physicians. Methods: We evaluated 20 Brazilian women between September and December 2007 with the WHOQOL-Bref instrument, VAS, McGill Pain Questionnaire, and Anxiety Adapted Scale. We interviewed the obstetrician with the VAS about the patient`s pain, Data were analyzed with the chi-square test. Results: Mean age was 22.35 years (SD = 6.24, range 15-39 years). It was necessary to use oxytocin in 15 (75%) patients, which had no correlation with anxiety degree. Higher intensity of pain (p < 0.05) and higher anxiety index (p < 0.05) were more common in women in the first pregnancy. Conclusions: Higher pain intensity was associated with higher anxiety levels (p < 0.05). Around half of the obstetricians` VAS scores were lower than the VAS scores of women, and probably pain at labor was underestimated and not controlled. Higher indices of anxiety and pain were associated, and were more frequent in women in the first pregnancy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. To compare pelvic floor muscle (PFM) strength between women undergoing vaginal delivery, cesarean section, and nulliparae, investigating the factors associated with PFM strength, and observing the correlation between vaginal digital palpation and use of a perineometer. Methods. A cross-sectional study was conducted, including 31 women following vaginal delivery, 30 women following cesarean section, and 30 nulliparous women. PFM strength was measured by vaginal digital palpation and use of a perineometer. Multiple linear regression analysis with adjustment for covariables was used to compare the mean PFM strength and identify its associated factors. Results. The mean PFM strength of women undergoing vaginal delivery and cesarean section was 25.6 +/- 14.5 cmH(2)O and 39.6 +/- 22.0 cmH(2)O (p < 0.01, adjusted for covariables), respectively. A correlation was observed between measurements of PFM strength obtained by vaginal digital palpation and use of a perineometer (tau = 0.82; p < 0.01). The non-white race/ethnicity was negatively associated with PFM strength (coefficient: -10.2424; p = 0.02). Conclusions. A lower PFM strength was observed in women with a history of vaginal delivery compared to those undergoing cesarean section. Non-white race/ethnicity negatively affected PFM strength. Our data suggest that vaginal digital palpation may be used in clinical practice because of its expressive correlation with use of a perineometer.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Obesity is epidemic worldwide, and increases in cesarean delivery rates have occurred in parallel. Objective: This study aimed to determine whether cesarean delivery is a risk factor for obesity in adulthood in a birth cohort of Brazilian subjects. Design: We initiated a birth cohort study in Ribeirao Preto, southeastern Brazil, in 1978. A randomly selected sample of 2057 subjects from the original cohort was reassessed in 2002-2004. Type of delivery, birth weight, maternal smoking, and schooling were obtained after birth. The following data from subjects were collected at 23-25 y of age: body mass index (BMI; in kg/m(2)), physical activity, smoking, and income. Obesity was defined as a BMI >= 30. A Poisson multivariable model was performed to determine the association between cesarean delivery and BMI. Results: The obesity rate in adults born by cesarean delivery was 15.2% and in those born by vaginal delivery was 10.4% (P = 0.002). Adults born by cesarean delivery had an increased risk (prevalence ratio: 1.58; 95% CI: 1.23, 2.02) of obesity at adulthood after adjustments. Conclusion: We hypothesize that increasing rates of cesarean delivery may play a role in the obesity epidemic worldwide. Am J Clin Nutr 2011;93:1344-7.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To study the association between maternal preeclampsia and neonatal sepsis in very low birth weight newborns. Study design We studied all infants with birth weights between 500 g and 1500 g who were admitted to 6 neonatal intensive care units of the Brazilian Network on Neonatal Research for 2 years. Exclusion criteria were major malformations, death in the delivery room, and maternal chronic hypertension. Absolute neutrophil count was performed in the first 72 hours of life. Results A total of 911 very low birth weight infants (preeclampsia, 308; non-preeclampsia, 603) were included. The preeclampsia group had significantly higher gestational age, more cesarean deliveries, antenatal steroid, central catheters, total parenteral nutrition, and neutropenia, and less rupture of membranes >18 hours and mechanical ventilation. Both groups had similar incidences of early sepsis (4.6% and 4.2% in preeclampsia and non-preeclampsia groups, respectively) and late sepsis (24% and 22.1% in preeclampsia and non-preeclampsia groups, respectively). Vaginal delivery and neutropenia were associated with multiple logistic regressions with early sepsis, and mechanical ventilation, central catheter, and total parenteral nutrition were associated with late sepsis. Death was associated with neutropenia in very preterm infants. Conclusions Preeclampsia did not increase neonatal sepsis in very low birth weight infants, and death was associated with neutropenia in very preterm infants. (J Pediatr 2010; 157: 434-8).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Atelectasis after either vaginal or Caesarean delivery has not been adequately quantified. This study addresses the hypothesis that atelectasis may be worse in women who undergo Caesarean section when compared with vaginal delivery under regional anaesthesia. Twenty healthy non-smoking women submitted to a chest computed tomography (CT) 2 h after delivery in a University Hospital, who had experienced vaginal delivery (n=10) under combined spinal-epidural analgesia or a Caesarean section (n=10) under spinal anaesthesia, were evaluated. The percentage cross-sectional area of atelectasis in dependent lung regions were measured from the CT images obtained at cross-section of the xiphoid process and the top of the diaphragm. The percentage cross-sectional area of atelectasis was 3.95% in the vaginal delivery group and 14.1% in the Caesarean group (P < 0.001, Mann-Whitney rank sum test). These results suggested that pulmonary atelectasis is greater after Caesarean section delivery under spinal anaesthesia than after vaginal delivery with combined spinal-epidural analgesia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to verify the possible association between the Sp1-binding site polymorphism and genital prolapse. A case-control study was conducted in 107 patients with stages III and IV genital prolapse. The control group included 209 women with stages 0 and I. The polymorphism of type I collagen Sp1-binding site was identified by amplification of the first intron of the COL1A1 gene. We did not find differences in the prevalence of the GT and TT genotypes between the groups (p=0.34), even when we grouped patients with at least one polymorphic allele (GT and TT) and compared them with patients without the polymorphic allele (GG; p=0.17) The presence of at least one vaginal delivery, family history for prolapse, and macrosomatic fetus were independent risk factors for prolapse. In conclusion, the COL1A1 Sp1-binding site was not significantly associated with genital prolapse among our study subjects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There seems to be controversy on the anorectal sphincter presentation and anatomical division, as well as on its functional representation. Evaluation of the anorectal sphincter musculature has been achieved through several methods, including anorectal manometry and computerized tomography, but to date there is no experimental model allowing a detailed manometric study of this muscle complex. In this work, we have developed such a model, which should enable the manometric and radiographic study of the anatomical features and functional mechanisms of sphincteric injuries, as well as the assessment of drug effects on the anorectal musculature upon incontinence and constipation. Twenty-two piglets (aged 25-30 days, weighing 5-7 kg) were studied by anorectal manometry (rectoanal inhibitory reflex and vector volume) and computerized tomography (anorectal angle and anal canal length). The data obtained for the rectoanal inhibitory reflex, represented here as the average and standard deviation, were the following: relaxation duration = 14.75 +/- 3.62 s, sphincter basal pressure = 41.58 +/- 8.20 mmHg, relaxation index = 87.26 +/- 11.52%, speed of relaxation = 5.90 +/- 2.10 mm/s, and speed of relaxation recovery = 4.03 +/- 1.78 mm/s. As for the vector volume, results were as follows: vector volume = 2692.32 +/- 1298.12 mmHg(2) cm, sphincter length = 11.82 +/- 2.74 mm, high pressure zone length = 5.09 +/- 1.34 mm, maximum pressure = 61.50 +/- 20.58 mmHg, and asymmetry index = 43.50 +/- 10.03%. Radiographic evaluation led to the following results: anal canal length = 9.61 +/- 2.14 mm and anorectal angle = 137.91 +/- 7.75 degrees. The experimental model designed here allows both anorectal manometry and computerized tomography to be carried out in the same way it is performed in human beings, as long as animal sedation is strictly controlled.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Anal incontinence causes psychological, social and adaptive troubles prejudicial to the quality of life both in children and adults. Therefore, the detailed knowledge of its causes and the improvement of diagnostic and therapeutic methods increase the possibilities of a more adequate social life to patients with congenital anomalies or sphincteric lesions or degenerations. In this work, a manometric study was developed through an experimental model so as to analyze alterations in behavior of muscle groups responsible for the anorectal sphincteric mechanism, previous to and after proximal and distal lesions. Twenty-two pigs aged between 25 and 30 days, weighing 5-7 kg, were randomly divided into two groups. They were submitted to lesions of different levels in the anorectal muscle. The animals were studied by anorectal manometry (rectoanal inhibitory reflex and vector volume) before and after the lesions. The Student t test and the Wilcoxon test were applied for the statistical analyses, considered p <= 0.05. The proximal lesion preserved sphincter relaxation, retarding its closure [speed of relaxation recovery 4.35 +/- 2.10 vs. 2.70 +/- 1.32 mm/s (p = 0.001)], but it reduced the maximum pressure [62.45 +/- 20.02 vs. 40.36 +/- 12.59 mmHg (p = 0.004)] and vector volume [2,749 +/- 921 vs. 1,591 +/- 1,379 mmHg(2)cm (p = 0.005)]. There was an increment in the high-pressure zone [5.09 +/- 1.04 vs. 6.36 +/- 1.50 mm (p = 0.005)], but the asymmetry percentage and the sphincter length were maintained. The distal lesion did not alter the rectoanal inhibitory reflex, the high-pressure zone length, the asymmetry percentage, or the vector volume. Nevertheless, the sphincter length increased [11.82 +/- 2.82 vs. 14.09 +/- 2.39 mm (p = 0.022)] and the maximum pressure decreased [60.55 +/- 22.05 vs. 40.91 +/- 13.41 mmHg (p = 0.004)]. The alterations observed due to proximal lesion of the anorectal sphincter suggest a direct and more important interference of the levator ani muscle in the function of the sphincteric musculature than that caused by the distal lesion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims: To evaluate the C-reactive protein (CRP) and interleukin-6 (IL-6) as diagnostic tools for early onset infection in preterm infants with early respiratory distress (RD). Methods: CRP and IL-6 were quantified at identification of RD and 24 h after in 186 newborns. Effects of maternal hypertension, mode of delivery, Apgar score, birth weight, gestational age, mechanical ventilation, being small for gestational age (SGA), and the presence of infection were analyzed. Results: Forty-four infants were classified as infected, 42 as possibly infected, and 100 as uninfected. Serum levels of IL-6 (0 h), CRP (0 h), and CRP (24 h), but not IL-6 (24 h) were significantly higher in infected infants compared to the remaining groups. The best test for identification of infection was the combination of IL-6 (0 h) 36 pg/dL and/or CRP (24 h) 0.6 mg/dL, which yielded 93% sensitivity and 37% specificity. The presence of infection and vaginal delivery independently increased IL-6 (0 h), CRP (0 h) and CRP (24 h) levels. Being SGA also increased the CRP (24 h) levels. IL-6 (24 h) was independently increased by mechanical ventilation. Conclusions: The combination of IL-6 (0 h) and/or CRP (24 h) is helpful for excluding early onset infection in preterm infants with RD but the poor specificity limits its potential benefit as a diagnostic tool.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to standardize signs and diagnostic criteria of respiratory function in newborn puppies delivered normally or after dystocia and caesarean operation. A total of 48 neonates were allocated into groups: eutocia (n = 20), dystocia (n = 8), caesarean (c)-section (n = 20). Neonatal health was assessed using the Apgar score and body temperature was determined at 0, 5 and 60 min after delivery. Venous blood gases (pO(2) and SO(2)) was measured immediately and 60 min after delivery, and a thoracic radiograph was made between 0 and 5 min of life. The c-section group had significantly lower Apgar scores at birth and 5 min. Hypothermia was present at 5 min in the eutocia and c-section groups, and at 60 min in all groups. The eutocia group had an irregular respiratory pattern in 78% of puppies at birth, 27.7% at 5 min and 21% at 60 min compared with 87.5%, 62.5% and 12.5% of the pups in the dystocia group where there was irregular respiratory rhythm, moderate to intense respiratory sounds with agonic episodes. The c-section group had respiratory alterations in 70%, 45% and 16% of puppies at 0, 5 and 60 min, respectively. Radiographic abnormalities were present in 17% of the pups in the eutocia group, 25% of the pups in the dystocia group and 30% of the pups in the c-section group, respectively. The c-section group had significantly lower SO(2) values at 60 min than at birth. All puppies had hypoxaemia, but a significant decrease was observed in the c-section group. Newborn puppies had tissue hypoxia and irregular respiratory pattern at birth. Caesarean-section puppies had lower vitality; however, all developed satisfactory Apgar scores at 5 min of life, regardless of the obstetric condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micropartículas produzidas a partir de polímeros sintéticos têm sido amplamente utilizadas na área farmacêutica para encapsulação de princípios ativos. Essas micropartículas apresentam as vantagens de proteção do princípio ativo, mucoadesão e gastrorresistência, melhor biodisponibilidade e maior adesão do paciente ao tratamento. Além disso, utiliza menores quantidade de princípio ativo para obtenção do efeito terapêutico proporcionando diminuição dos efeitos adversos locais, sistêmicos e menor toxidade. Os polímeros sintéticos empregados na produção das micropartículas são classificados biodegradáveis ou não biodegradáveis, sendo os biodegradáveis mais utilizados por não necessitam ser removidos cirurgicamente após o término de sua ação. A produção das micropartículas poliméricas sintéticas para encapsulação tanto de ativos hidrofílicos quanto hidrofóbicos pode ser emulsificação por extração e/ou evaporação do solvente; coacervação; métodos mecânicos e estão revisados neste artigo evidenciando as vantagens, desvantagens e viabilidade de cada metodologia. A escolha da metodologia e do polímero sintético a serem empregados na produção desse sistema dependem da aplicação terapêutica requerida, bem como a simplicidade, reprodutibilidade e factibilidade do aumento de escala da produção.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we propose natural rubber latex (NRL) membranes as a protein delivery system. For this purpose Bovine Serum Albumin (BSA) was incorporated into the latex solution for in vitro protein delivery experiments. Different polymerization temperatures were used, from -10 to 27 °C, in order to control the membrane morphology. These membranes were characterized by Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), as well as the Lowry Method to measure the BSA release. SEM and AFM microscopy analysis showed that the number, size and distribution of pores in NRL membranes can be varied, as well as its overall morphology. We have found that the morphology of the membrane is the predominant factor for higher protein release, compared with pore size and number of pores. Results demonstrated that the best drug-delivery system was the membrane polymerized at RT (27 °C), which does release 66% of its BSA content for up to 18 days. Our results indicate that NRLb could be used in the future as an active membrane that could accelerate bone healing in GBR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudos populacionais sobre mortalidade neonatal de nascimentos de muito baixo peso ao nascer contribuem para identificar sua complexa rede de fatores de risco. Foi estudada uma coorte de 213 recém-nascidos com peso inferior a 1.500g (112 óbitos neonatais e 101 sobreviventes) na Região Sul do Município de São Paulo, Brasil, em 2000/2001. Foram realizadas entrevistas domiciliares e obtidos dados de prontuários hospitalares. Foi realizada análise de sobrevida e empregada regressão múltipla de Cox. A elevada mortalidade na sala de parto, no primeiro dia de vida e ausência de sobreviventes < 700g dos nascimentos < 1.000g e com menos de 28 semanas sugere que condutas mais ativas destinam-se a nascituros de maior viabilidade. Mães residentes em favela, com história anterior de cesárea e aborto provocado, adolescentes, com sangramento vaginal e ausência de pré-natal aumentaram o risco de óbito neonatal. Partos cesarianos e internação em berçários mostraram efeito protetor. O peso ao nascer abaixo de 1.000g e Apgar menor que 7 foram risco. A elevada mortalidade está associada às condições de vida, características maternas e dos nascimentos e condições assistenciais. A melhoria da atenção pré-natal e ao recém-nascido pode atuar na redução da mortalidade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: An evaluation of patients' preferences is necessary to understand the demand for different insulin delivery systems. The aim of this study was to investigate the association between socioeconomic status (SES) and patients' preferences and willingness to pay (WTP) for various attributes of insulin administration for diabetes management. Methods: We conducted a discrete choice experiment (DCE) to determine patients' preferences and their WTP for hypothetical insulin treatments. Both self-reported annual household income and education completed were used to explore differences in treatment preferences and WTP for different attributes of treatment across different levels of SES. Results: The DCE questionnaire was successfully completed by 274 patients. Overall, glucose control was the most valued attribute by all socioeconomic groups, while route of insulin delivery was not as important. Patients with higher incomes were willing to pay significantly more for better glucose control and to avoid adverse events compared to lower income groups. In addition, they were willing to pay more for an oral short-acting insulin ($Can 71.65 [95% confidence interval, $40.68, $102.62]) compared to the low income group ($Can 9.85 [95% confidence interval, 14.86, 34.56; P < 0.01]). Conversely, there were no differences in preferences when the sample was stratified by level of education. Conclusions: This study revealed that preferences and WTP for insulin therapy are influenced by income but not by level of education. Specifically, the higher the income, the greater desire for an oral insulin delivery system, whereas an inhaled route becomes less important for patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The magnetic albumin nanosphere (MAN), encapsulating maghemite nanoparticles, was designed as a magnetic drug delivery system (MDDS) able to perform a variety of biomedical applications. It is noteworthy that MAN was efficient in treating Ehrlich's tumors by the magnetohyperthermia procedure. Methods and materials: In this study, several nanotoxicity tests were systematically carried out in mice from 30 minutes until 30 days after MAN injection to investigate their biocompatibility status. Cytometry analysis, viability tests, micronucleus assay, and histological analysis were performed. Results: Cytometry analysis and viability tests revealed MAN promotes only slight and temporary alterations in the frequency of both leukocyte populations and viable peritoneal cells, respectively. Micronucleus assay showed absolutely no genotoxicity or cytotoxicity effects and histological analysis showed no alterations or even nanoparticle clusters in several investigated organs but, interestingly, revealed the presence of MAN clusters in the central nervous system (CNS). Conclusion: The results showed that MAN has desirable in vivo biocompatibility, presenting potential for use as a MDDS, especially in CNS disease therapy.