59 resultados para Ultrasound (US)
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
The therapeutic ultrasound (US) is one of the resources mostly used by physiotherapists; however the use of uncalibrated equipments results in inefficient or even harmful therapies to the patient. In this direction, the objective of this study was to evaluate the performance and the procedures of utilization and maintenance of US in use in clinics and Physical-therapy offices. A questionnaire with questions related to the procedures applied in service during the use of therapeutic ultrasound was applied to physiotherapists. The performance of 31 equipments of 6 different brands and 13 different models was evaluated according to the IEC 61689 norm. The parameters measured were: acoustic power; effective radiating area (AER); non-uniformity ratio of the beam (RBN); maximum effective intensity; acoustic frequency of operation, modulation factor and wave form on pulsate mode. As for the questionnaires, it was evident that the professionals are not concerned about the calibration of the equipment. The results demonstrated that only 32.3% of the equipments were in accordance with the norms for the variables power and effective radiation area. The frequency analysis indicated that 20% of the 3 MHz transducers and 12.5% of the 1 MHz contemplated the norms. In the pulsate mode, 12.7% presented relation rest/duration inside allowed limits. A great variation of the ultrasonic field was observed on the obtained images, which presented beams not centered, sometimes with bifurcation of its apex. The results allow concluding that, although used in therapeutic sessions with the population, none of the equipments presents all the analyzed variables inside technical norms. (C) 2010 Elsevier B. V. All rights reserved.
Resumo:
In vitro skin permeation of hyaluronidase enzyme and the ultrasound (US) effects on cutaneous permeation of this enzyme were investigated. Diffusion cell technique, porcine skins, buffer solution, and a hydrophilic gel+hyaluronidase (100 TUR/g), were used for study. The experimental groups were: gel+enzyme and gel+enzyme+US. The activity of permeated hyaluronidase was determined by turbydimetric method in spectrophotometer at 400nm. Gel+enzyme group permitted a diffusion of 26.89 +/- 3.82 TUR of hyaluronidase in the total time of 240 minutes. However, the other group did not produce significant differences (p0.05) in the same period (13.68 +/- 5.35 TUR). Hyaluronidase permeation through the skin was verified; however US did not cause increase of this enzyme permeation.
Resumo:
Symptomatic benign prostatic hyperplasia (BPH) typically occurs in the sixth and seventh decades, and the most frequent obstructive urinary symptoms are hesitancy, decreased urinary stream, sensation of incomplete emptying, nocturia, frequency, and urgency. Various medications, specifically 5-alpha-reductase inhibitors and selective alpha-blockers, can decrease the severity of the symptoms secondary to BPH, but prostatectomy is still considered to be the traditional method of management. We report the preliminary results for two patients with acute urinary retention due to BPH, successfully treated by prostate artery embolization (PAE). The patients were investigated using the International Prostate Symptom Score, by digital rectal examination, urodynamic testing, prostate biopsy, transrectal ultrasound (US), and magnetic resonance imaging (MRI). Uroflowmetry and postvoid residual urine volume complemented the investigation at 30, 90, and 180 days after PAE. The procedure was performed under local anesthesia; embolization of the prostate arteries was performed with a microcatheter and 300- to 500-mu m microspheres using complete stasis as the end point. One patient was subjected to bilateral PAE and the other to unilateral PAE; they urinated spontaneously after removal of the urethral catheter, 15 and 10 days after the procedure, respectively. At 6-month follow-up, US and MRI revealed a prostate reduction of 39.7% and 47.8%, respectively, for the bilateral PAE and 25.5 and 27.8%, respectively, for the patient submitted to unilateral PAE. The early results, at 6-month follow-up, for the two patients with BPH show a promising potential alternative for treatment with PAE.
Resumo:
Background/Aims: Hepatocellular carcinoma (HCC) is a well recognized complication of advanced NASH (non-alcoholic steatohepatitis). We sought to produce a rat model of NASH, cirrhosis and HCC. Methods: Adult Sprague-Dawley rats, weighing 250-300 g, were fed a choline-deficient, high trans-fat diet and exposed to DEN in drinking water. After 16 weeks, the animals underwent liver ultrasound (US), sacrifice and assessment by microscopy, immunohistochemistry and transmission electron microscopy (TEM). Results: US revealed steatosis and focal lesions in 6 of 7. All had steatohepatitis defined as inflammation, advanced fibrosis and ballooning with Mallory-Denk bodies (MDB) with frank cirrhosis in 6. Areas of more severe injury were associated with anti-CK19 positive ductular reaction. HCC, present in all, were macro-trabecullar or solid with polyhedral cells with foci of steatosis and ballooned cells. CK19 was positive in single or solid nests of oval cells and in neoplastic hepatocytes. TEM showed ballooning with small droplet fat, dilated endoplasmic reticulum and MDB in non-neoplastic hepatocytes and small droplet steatosis in some cancer cells. Conclusions: This model replicated many features of NASH including steatohepatitis with ballooning, fibrosis, cirrhosis and hepatocellular carcinoma. Oval cell proliferation was evident and the presence anti-CK 19 positivity in the cancer suggests oval cell origin of the malignancy. (C) 2008 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
Resumo:
OBJECTIVE To evaluate the correlation between ultrasound-estimated bladder weight (UEBW) in patients with different degrees of bladder outlet obstruction (BOO). METHODS We evaluated 50 consecutive non-neurogenic male patients with lower urinary tract symptoms (LUTS) referred to urodynamic study (UDS). All patients self-answered the International Prostate Score Symptoms (IPSS) questionnaire. After the UDS, the bladder was filled with 150 mL to determine UEBW. Patients with a bladder capacity under 150 mL, a previous history of prostate surgery or pelvic irradiation, an IPSS score <8, a bladder stone or urinary tract infection were excluded. After a pressure-flow study, the Schafer linear passive urethral resistance relation nomogram was plotted to determine the grade of obstruction: Grades I-II/VI were defined as mild obstruction, Grades III-IV/VI as moderate obstruction, and Grades V-VI/VI as severe obstruction. RESULTS The UEBW was 51.7 +/- 26.9, 54.1 +/- 30.0 and 54.8 +/- 28.2 in patients with mild, moderate and severe BOO, respectively (P = 0.130). The UEBW allowed us to define four groups: (i) UEBW < 35 g; (ii) 35 g <= UEBW < 50 g; (iii) 50 g <= UEBW < 70 g; and (4) UEBW >= 70 g. We did not find any differences in age, prostate weight, IPSS, PVR, cystometric bladder capacity, presence of detrusor overactive and degree of obstruction in the aforementioned groups. CONCLUSION Despite the fact that some studies have emphasized the value of UEBW as an efficient non-invasive method for evaluating lower urinary tract obstruction, our study suggests that UEBW does not present any individual correlation with LUTS or objective measurements of BOO.
Resumo:
To describe clinical and ultrasound findings in a patient with infantile systemic hyalinosis (ISH). A 5-month-old boy was evaluated of joint contractures. In addition to clinical and laboratory investigations, an ultrasound of his joints was done and compared to a child with similar age. On examination, a short neck, gingival hyperplasia and papular rash were noted. Joint examination showed painful passive movement, reduced range of motion, and joint contractures in knees, elbows, and small joints of the hands, without any evidence of synovial thickness. Ultrasound of the affected joints showed irregular cortical surface of MCPs and PIP, the presence of osteophytes and bone erosions, increased synovial fluid without evidence of synovial hyperplasia. This is the first report to show evidence of US findings in ISH. Ultrasound findings may help to distinguish ISH from JIA in early stages.
Resumo:
OBJECTIVES: Causes may be found in most cases of acute pancreatitis, however no etiology is found by clinical, biological and imaging investigations in 30% of these cases. Our objective was to evaluate results from endoscopic ultrasonography (EUS) for diagnosis of gallbladder microlithiasis in patients with unexplained (idiopathic) acute pancreatitis. METHODS: Thirty-six consecutive non-alcoholic patients with diagnoses of acute pancreatitis were studied over a five-year period. None of them showed signs of gallstones on transabdominal ultrasound or tomography. We performed EUS within one week of diagnosing acute pancreatitis. Diagnosis of gallbladder microlithiasis on EUS was based upon findings of hyperechoic signals of 0.5-3.0 mm, with or without acoustic shadowing. All patients (36 cases) underwent cholecystectomy, in accordance with indication from the attending physician or based upon EUS diagnosis. RESULTS: Twenty-seven patients (75%) had microlithiasis confirmed by histology and nine did not (25%). EUS findings were positive in twenty-five. Two patients had acute cholecystitis diagnosed at EUS that was confirmed by surgical and histological findings. In two patients, EUS showed cholesterolosis and pathological analysis disclosed stones not detected by EUS. EUS diagnosed microlithiasis in four cases not confirmed by surgical treatment. In our study, sensitivity, specificity and positive and negative predictive values to identify gallbladder microlithiasis (with 95% confidence interval) were 92.6% (74.2-98.7%), 55.6% (22.7-84.7%), 86.2% (67.4-95.5%) and 71.4% (30.3-94.9%), respectively. Overall EUS accuracy was 83.2%. CONCLUSIONS: EUS is a very reliable procedure to diagnose gallbladder microlithiasis and should be used for the management of patients with unexplained acute pancreatitis. This procedure should be part of advanced endoscopic evaluation.
Resumo:
Technical evaluation of analytical data is of extreme relevance considering it can be used for comparisons with environmental quality standards and decision-making as related to the management of disposal of dredged sediments and the evaluation of salt and brackish water quality in accordance with CONAMA 357/05 Resolution. It is, therefore, essential that the project manager discusses the environmental agency's technical requirements with the laboratory contracted for the follow-up of the analysis underway and even with a view to possible re-analysis when anomalous data are identified. The main technical requirements are: (1) method quantitation limits (QLs) should fall below environmental standards; (2) analyses should be carried out in laboratories whose analytical scope is accredited by the National Institute of Metrology (INMETRO) or qualified or accepted by a licensing agency; (3) chain of custody should be provided in order to ensure sample traceability; (4) control charts should be provided to prove method performance; (5) certified reference material analysis or, if that is not available, matrix spike analysis, should be undertaken and (6) chromatograms should be included in the analytical report. Within this context and with a view to helping environmental managers in analytical report evaluation, this work has as objectives the discussion of the limitations of the application of SW 846 US EPA methods to marine samples, the consequences of having data based on method detection limits (MDL) and not sample quantitation limits (SQL), and present possible modifications of the principal method applied by laboratories in order to comply with environmental quality standards.
Resumo:
Currently, the acoustic and nanoindentation techniques are two of the most used techniques for material elastic modulus measurement. In this article fundamental principles and limitations of both techniques are shown and discussed. Last advances in nanoindentation technique are also reviewed. An experimental study in ceramic, metallic, composite and single crystals was also done. Results shown that ultrasonic technique is capable to provide results in agreement with those reported in literature. However, ultrasonic technique does not allow measuring the elastic modulus of some small samples and single crystals. On the other hand, the nanoindentation technique estimates the elastic modulus values in reasonable agreement with those measured by acoustic methods, particularly in amorphous materials, while in some policristaline materials some deviation from expected values was obtained.
Resumo:
Methods currently employed to establish the etiology of congenital hypothyroidism include thyroid ultrasound and scintigraphic exams. Thyroglobulin is a protein almost exclusively secreted by thyroid tissue and indirectly reflects the amount of follicular cells. Even though thyroglobulin is easy to measure, it has been not frequently used because of discordant results to distinguish mainly athyreosis and ectopy (dysgenesis). Knowing the differences in inheritance and prognosis of thyroid dysgenesis and dyshormonogenesis, it is important to define the etiology of CH, combining tools that are easy, fast and available in most medical centers. Our objective was to evaluate and compare color Doppler ultrasound and serum thyroglobulin with radionuclide scan to define the etiology of congenital hypothyroidism. We evaluated 38 children above 3 years-old off-treatment that performed serum thyroglobulin by immunofluorometric assay, color Doppler ultrasound and radionuclide study. On color Doppler ultrasound, 11 patients had athyreosis, 5 ectopic glands, being I associated to hemiagenesis. Twenty one had topic thyroid (3 goiters, 10 normal, 8 hypoplastic). Hemiagenesis and cystic lesion were not revealed by radionuclide scan. We observed substantial agreement between color Doppler ultrasound and radionuclide scan (kappa=0.745, p<0.0001). Serum thyroglobulin in athyreosis ranged from <1.0 to 18.7 mu g/L. Patients with ectopic glands showed wider thyroglobulin range (4.5 to 123 mu g/L, median 28.4 mu g/L). Only one patient showed thyroglobulin deficiency. By using color Doppler ultrasound and serum thyroglobulin levels as valuable combined tools, we established the etiology of congenital hypothyroidism limiting excessive and harmful exams in children, like radionuclide scan.
Resumo:
Over two-thirds of renal masses noted incidentally on abdominal CT scans performed for nonurological indications are most likely renal cell carcinoma (RCC). The prognosis in these instances is often quite favorable, as early diagnosis offers the best hope of a complete cure. We report the identification of a RCC incidentally at endoscopic ultrasound (EUS) while an earlier CT scan of abdomen was negative. The mass was biopsied resulting in a histological confirmation of RCC and successful surgical resection.
Resumo:
In this article, we discuss school schedules and their implications in the context of chronobiological contemporary knowledge, arguing for the need to reconsider time planning in the school setting. We present anecdotal observations regarding chronobiological challenges imposed by the school system throughout different ages and discuss the effects of these schedules in terms of sleepiness and its deleterious consequences on learning, memory, and attention. Different settings (including urban vs. rural habitats) influence timing, which also depends on self-selected sleep schedules. Finally, we criticize the traditional view of a necessary strict stability of sleep-wake habits.
Resumo:
Lipases from different sources, Pseudomonas fluorescens (AK lipase), Burkholderia cepacia (PS lipase), Penicillium camembertii (lipase G) and Porcine pancreas lipase (PPL), previously immobilized on epoxy SiO(2)-PVA, were screened for the synthesis of xylitol monoesters by esterification of the protected xylitol using oleic acid as acyl donor group. Among all immobilized derivatives, the highest esterification yield was achieved by P. camembertii lipase, showing to be attractive alternative to bulk chemical routes to satisfy increasing commercial demands. Further experiments were performed to determine the influence of fatty acids chain size on the reaction yield and the feasibility of using non-conventional heating systems (microwave and ultrasound irradiations) to enhance the reaction rate. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Bittar CK, Cliquet A Jr, dos Santos Floter M: Utility of quantitative ultrasound of the calcaneus in diagnosing osteoporosis in spinal cord injury patients. Am J Phys Med Rehabil 2011;90:477-481. Objective: The aim of this study was to assess the utility of quantitative ultrasound of the calcaneus in diagnosing osteoporosis in spinal cord injury patients in a Brazilian Teaching Hospital. Design: This is a diagnostic test criterion standard comparison study. Between January 2008 and October 2009, the bone density of 15 spinal cord injury patients was assessed for analysis before beginning rehabilitation using muscle stimulation. The bone density was assessed using bone densitometry examination (DEXA) and ultrasound examination of the calcaneus (QUS). The measurements acquired using QUS and DEXA were compared between patients with spinal cord injury and a control group of ten healthy individuals. Results: The T-score values for femoral neck using DEXA (P < 0.0022) and those using QUS of the calcaneus (P < 0.0005) differed significantly between the groups, and the means in the normal subjects were higher than those in spinal cord injury patients who would receive electrical stimulation. In spinal cord injury patients, the significant differences were found between the QUS T-score for calcaneus and the DEXA scores for the lumbar spine and femoral neck. Conclusions: Because of the low level of mechanical stress on the calcaneus, the results of the QUS could not be correlated with the DEXA results for diagnosing osteoporosis. Therefore, QUS seems to be not a good choice for diagnosis and follow-up.
Resumo:
The aim of this study was to measure the temporal expression of osteogenic genes during the process of bone healing in low-intensity pulsed ultrasound (LIPUS) treated bone defects by means of histopathologic and real-time polymerase chain reaction (PCR) analysis. Animals were randomly distributed into two groups (n = 30): control group (bone defect without treatment) and LIPUS treated (bone defect treated with LIPUS). On days 7, 13 and 25 postinjury, 10 rats per group were sacrificed. Rats were treated with a 30 mW/cm(2) LIPUS. The results pointed out intense new bone formation surrounded by highly vascularized connective tissue presenting a slight osteogenic activity, with primary bone deposition was observed in the group exposed to LIPUS in the intermediary (13 days) and late stages of repair (25 days) in the treated animals. In addition, quantitative real-time polymerase chain reaction (RT-qPCR) showed an upregulation of bone morphogenetic protein 4 (BMP4), osteocalcin and Runx2 genes 7 days after the surgery. In the intermediary period, there was no increase in the expression. The expression of alkaline phosphatase, BMP4 and Runx2 was significantly increased at the last period. Our results indicate that LIPUS therapy improves bone repair in rats and upregulated osteogenic genes, mainly at the late stages of recovery. (E-mail: a.renno@unifesp.br) (C) 2010 Published by Elsevier Inc. on behalf of World Federation for Ultrasound in Medicine & Biology.