243 resultados para Transmission System

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design of supplementary damping controllers to mitigate the effects of electromechanical oscillations in power systems is a highly complex and time-consuming process, which requires a significant amount of knowledge from the part of the designer. In this study, the authors propose an automatic technique that takes the burden of tuning the controller parameters away from the power engineer and places it on the computer. Unlike other approaches that do the same based on robust control theories or evolutionary computing techniques, our proposed procedure uses an optimisation algorithm that works over a formulation of the classical tuning problem in terms of bilinear matrix inequalities. Using this formulation, it is possible to apply linear matrix inequality solvers to find a solution to the tuning problem via an iterative process, with the advantage that these solvers are widely available and have well-known convergence properties. The proposed algorithm is applied to tune the parameters of supplementary controllers for thyristor controlled series capacitors placed in the New England/New York benchmark test system, aiming at the improvement of the damping factor of inter-area modes, under several different operating conditions. The results of the linear analysis are validated by non-linear simulation and demonstrate the effectiveness of the proposed procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new, simple approach for modeling and assessing the operation and response of the multiline voltage-source controller (VSC)-based flexible ac transmission system controllers, namely the generalized interline power-flow controller (GIPFC) and the interline power-flow controller (IPFC), is presented in this paper. The model and the analysis developed are based on the converters` power balance method which makes use of the d-q orthogonal coordinates to thereafter present a direct solution for these controllers through a quadratic equation. The main constraints and limitations that such devices present while controlling the two independent ac systems considered, will also be evaluated. In order to examine and validate the steady-state model initially proposed, a phase-shift VSC-based GIPFC was also built in the Alternate Transients Program program whose results are also included in this paper. Where applicable, a comparative evaluation between the GIPFC and the IPFC is also presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We derive an easy-to-compute approximate bound for the range of step-sizes for which the constant-modulus algorithm (CMA) will remain stable if initialized close to a minimum of the CM cost function. Our model highlights the influence, of the signal constellation used in the transmission system: for smaller variation in the modulus of the transmitted symbols, the algorithm will be more robust, and the steady-state misadjustment will be smaller. The theoretical results are validated through several simulations, for long and short filters and channels.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This research presents the development and implementation in a computational routine of algorithms for fault location in multiterminal transmission lines. These algorithms are part of a fault-location system, which is capable of correctly identifying the fault point based on voltage and current phasor quantities, calculated by using measurements of voltage and current signals from intelligent electronic devices, located on the transmission-line terminals. The algorithms have access to the electrical parameters of the transmission lines and to information about the transformers loading and their connection type. This paper also presents the development of phase component models for the power system elements used by the fault-location algorithms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rabies is a viral zoonotic infectious disease that affects mammals and is caused by genotypes/species of the Lyssavirus genus (Rhabdoviridae, Mononegavirales), with the genotype 1 (classic rabies virus - RABV) being the most prevalent. Despite continuous efforts, rabies is still an incurable disease that causes thousands of deaths amongst humans worldwide. Due to a wide range of hosts and the different evolutionary paths of RABV in each host, several host-specific variants have arisen in an ongoing process. The result of RABV replication in nervous tissues may lead to two opposite clinical outcomes, i.e., paralytic/dumb form and encephalitic/furious one. The paralytic form creates dead-end hosts mainly amongst herbivores, while the furious form of the disease allows for augmented transmission when manifested in gregarious carnivores, as their natural aggressive behavior is accentuated by the disease itself. The aim of this article is to propose a theoretical model intended to explore how the rabies virus intrinsically modulates the immune system of different host classes, the pathological changes that the virus causes in these animals and how these elements favor its own perpetuation in nature, thus providing a basis for better prediction of the patterns this disease may present.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe the male reproductive system of the intertidal hermit crab Calcinus tihicen, with emphasis on the sexual apparatus, spermatophore, and spermatozoa. The crabs were collected on the rocky shore of Praia Grande Beach, Ubatuba, southeastern Brazil. The morphological analysis, based on 30 specimens, was made with the use of a stereomicroscope, an optical microscope, and scanning and transmission electron microscopes. The male reproductive system is composed of a pair of juxtaposed testes, located dorsally in the pleon. From each testis emerges a vas deferens that links it to the exterior by the gonopores. located on the base of the fifth pair of pereiopods. The vas deferens has three macroscopically distinct regions that contain spermatophores in different stages of maturation. The spermatophore morphology is similar to that of other members of Paguroidea, having a distal, nearly spherical ampulla containing spermatozoa; an approximately cylindrical peduncle and a proximal foot connecting the spermatophores. We describe, for the first time, the variability in the spermatophore morphology and size in the three regions of the vas deferens using the type species of the genus Calcinus. The spermatozoa have three main regions (the acrosomal vesicle, the nucleus, and the cytoplasm). The morphological similarity of the male reproductive system of C. tihicen with previously studied species of Diogenidae is an indicative of complex phylogenetic relationships among the members of the genus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an approach for the active transmission losses allocation between the agents of the system. The approach uses the primal and dual variable information of the Optimal Power Flow in the losses allocation strategy. The allocation coefficients are determined via Lagrange multipliers. The paper emphasizes the necessity to consider the operational constraints and parameters of the systems in the problem solution. An example, for a 3-bus system is presented in details, as well as a comparative test with the main allocation methods. Case studies on the IEEE 14-bus systems are carried out to verify the influence of the constraints and parameters of the system in the losses allocation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new approach to the transmission loss allocation problem in a deregulated system. This approach belongs to the set of incremental methods. It treats all the constraints of the network, i.e. control, state and functional constraints. The approach is based on the perturbation of optimum theorem. From a given optimal operating point obtained by the optimal power flow the loads are perturbed and a new optimal operating point that satisfies the constraints is determined by the sensibility analysis. This solution is used to obtain the allocation coefficients of the losses for the generators and loads of the network. Numerical results show the proposed approach in comparison to other methods obtained with well-known transmission networks, IEEE 14-bus. Other test emphasizes the importance of considering the operational constraints of the network. And finally the approach is applied to an actual Brazilian equivalent network composed of 787 buses, and it is compared with the technique used nowadays by the Brazilian Control Center. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, the innovation approach is used to estimate the measurement total error associated with power system state estimation. This is required because the power system equations are very much correlated with each other and as a consequence part of the measurements errors is masked. For that purpose an index, innovation index (II), which provides the quantity of new information a measurement contains is proposed. A critical measurement is the limit case of a measurement with low II, it has a zero II index and its error is totally masked. In other words, that measurement does not bring any innovation for the gross error test. Using the II of a measurement, the masked gross error by the state estimation is recovered; then the total gross error of that measurement is composed. Instead of the classical normalised measurement residual amplitude, the corresponding normalised composed measurement residual amplitude is used in the gross error detection and identification test, but with m degrees of freedom. The gross error processing turns out to be very simple to implement, requiring only few adaptations to the existing state estimation software. The IEEE-14 bus system is used to validate the proposed gross error detection and identification test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During the last few years, the evolution of fieldbus and computers networks allowed the integration of different communication systems involving both production single cells and production cells, as well as other systems for business intelligence, supervision and control. Several well-adopted communication technologies exist today for public and non-public networks. Since most of the industrial applications are time-critical, the requirements of communication systems for remote control differ from common applications for computer networks accessing the Internet, such as Web, e-mail and file transfer. The solution proposed and outlined in this work is called CyberOPC. It includes the study and the implementation of a new open communication system for remote control of industrial CNC machines, making the transmission delay for time-critical control data shorter than other OPC-based solutions, and fulfilling cyber security requirements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study was designed to determine the prevalence and extended-spectrum beta-lactamase (ESBL) types in clinical isolates of Klebsiella spp. at a university hospital located in the Brazilian southern region (Ribeirao Preto, Sao Paulo) as well as their antibiotic susceptibility and genetic profiles. This study included 147 non-repeat Klebsiella spp. isolates collected from January to June 2000, of which 23 K. pneumoniae and 8 K. oxytoca were selected as ESBL producers by using the Oxoid combination disk method and Etest ESBL strip. beta-lactamases were characterized by IEF, PCR and sequencing assays using primers for ESBL genes. Antibiotic susceptibility was evaluated by MicroScan system. Dissemination of two major clones of ESBL-producing Klebsiella spp. occurred in the hospital. According to the results obtained in this study there was a clonal spread of CTX-M-producing K. oxytoca in five clinics and dissemination of ESBL-producing K. pneumoniae in the nursery and pediatrics wards.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study, the morphology and biometry of the spermatophores of the western Atlantic hermit crab Clibanarius sclopetarius (Herbst, 1796) are described, and the results are placed in the context of the Paguroidea, in particular the Diogenidae. Individuals of C. sclopetarius were sampled from a human-impacted mangrove area of southern Brazil. The male reproductive system was removed, measured and analyzed using stereoscopic, light, transmission-electron and scanning-electron microscopy. This system is composed of lobular testes connected to the vas deferens, and gonopores with membranous coverage. The mature spermatophore consists of a spherical pack that stores sperm. These cells consist of a spherical acrosomal vesicle, an amorphous cytoplasm and a distal nucleus. The results revealed that the gonopores, testis and vas deferens have the expected characteristics of the family Diogenidae, while the non-tripartite morphology of the spermatophores and the sperm follow the patterns found only in the genus Clibanarius, and the presence of the dense perforatorial ring is, to date, unique in the species of the genus, being a possible apomorphic characteristic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The influence of the preparation method on the structural properties of the RuO(2)-Ta(2)O(5) system was investigated. Both thin films on Ti substrates and powder samples of nominal composition Ti/RuO(2)-Ta(2)O(5) (Ru:Ta = 100:0, 90:10, 80:20, 30:70, and 0:100 at.%) were prepared through thermal decomposition of polymeric precursors (DPP). The thin films and powder samples were investigated using X-ray absorption spectroscopy (XAS). XANES analyses showed that Ru and Ta are present in the Ru(IV) and Ta(V) oxidation states. EXAFS signals of all the samples were analyzed, to obtain the average bond length (r), coordination number, and the Debye-Waller factor (sigma(2)) for each Ru-O, Ru-Ru, Ta-O nearest-neighbor. The first shell Ru-O distance was found at 1.91-1.92 angstrom with coordination number of 1.8-2.1, and at 2.01-2.02 angstrom with coordination number of 3.9-4.1. The Ta-O distance obtained for all the samples and in both modes (transmission and fluorescence) had significantly different values from the theoretical ones. The results revealed that the local structure around both the Ru and Ta sites are similar, and that they consist of distorted M-O(6) octahedra (where M = Ru or Ta). (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Early Alzheimer`s disease (AD) pathophysiology is characterized by synaptic changes induced by degradation products of amyloid precursor protein (APP). The exact mechanisms of such modulation are unknown. Here, we report that nanomolar concentrations of intraaxonal oligomeric (o)A beta 42, but not oA beta 40 or extracellular oA beta 42, acutely inhibited synaptic transmission at the squid giant synapse. Further characterization of this phenotype demonstrated that presynaptic calcium currents were unaffected. However, electron microscopy experiments revealed diminished docked synaptic vesicles in oA beta 42-microinjected terminals, without affecting clathrin-coated vesicles. The molecular events of this modulation involved casein kinase 2 and the synaptic vesicle rapid endocytosis pathway. These findings open the possibility of a new therapeutic target aimed at ameliorating synaptic dysfunction in AD.