6 resultados para Telephone equipment.

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To assess risk and protective factors for chronic noncommunicable diseases (CNCD) and to identify social inequalities in their distribution among Brazilian adults. METHODS: The data used were collected in 2007 through VIGITEL, an ongoing population-based telephone survey. This surveillance system was implemented in all of the Brazilian State capitals, over 54,000 interviews were analyzed. Age-adjusted prevalence ratios for trends at different schooling levels were calculated using Poisson regression with linear models. RESULTS: These analyses have shown differences in the prevalence of risk and protective factors for CNCD by gender and schooling. Among men, the prevalence ratios of overweight, consumption of meat with visible fat, and dyslipidemia were higher among men with more schooling, while tobacco use, sedentary lifestyle, and high-blood pressure were lower. Among women, tobacco use, overweight, obesity, high-blood pressure and diabetes were lower among men with more schooling, and consumption of meat with visible fat and sedentary lifestyles were higher. As for protective factors, fruit and vegetables intake and physical activity were higher in both men and women with more schooling. CONCLUSION: Gender and schooling influence on risk and protective factors for CNCD, being the values less favorable for men. vigitel is a useful tool for monitoring these factors amongst the Brazilian population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents a decision-making method for maintenance policy selection of power plants equipment. The method is based on risk analysis concepts. The method first step consists in identifying critical equipment both for power plant operational performance and availability based on risk concepts. The second step involves the proposal of a potential maintenance policy that could be applied to critical equipment in order to increase its availability. The costs associated with each potential maintenance policy must be estimated, including the maintenance costs and the cost of failure that measures the critical equipment failure consequences for the power plant operation. Once the failure probabilities and the costs of failures are estimated, a decision-making procedure is applied to select the best maintenance policy. The decision criterion is to minimize the equipment cost of failure, considering the costs and likelihood of occurrence of failure scenarios. The method is applied to the analysis of a lubrication oil system used in gas turbines journal bearings. The turbine has more than 150 MW nominal output, installed in an open cycle thermoelectric power plant. A design modification with the installation of a redundant oil pump is proposed for lubricating oil system availability improvement. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development and Characterization of L-Alanyl-L-Glutamine Containing Pellets employing Extrusion-Spheronization Method and Drying Process in Fluidized Bad Equipment"". In this work, five formulations of L-alanyl-L-glutamine (glutamine dipeptide) containing pellets with different drug concentration were developed and evaluated: F1 (9.07%); F2 (17.70%); F3 (27.98%); F4 (37.74%) e F5 (47.53%). Pellets were prepared by extrusion-spheronization method and, further, dried in fluidized bad equipment. The following assays were carried out with the batches obtained: granulometry, friability, true density and morphologic analysis. Between the five formulations evaluated, pellets obtained from F3 present best yield (75.80%), most uniform particle size distribution (89.67% of pellets with size in the range of 0.80 to 1.18), most high true density (2.1634 g/ml) and best aspect (1.0795 +/- 0.0410). Due to these features, pellets obtained from F3 were considered adequate to further polymeric coating process in order to produce a multiparticulate system to prolong L-alanyl-L-glutamine release.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. This article evaluates the comparability of the telephone and in-person Structured Clinical Interview for DSM-IV (SCID) interviews in assessing patients with social anxiety disorder (SAD) as an independent anxiety diagnosis. DESIGN AND METHODS. One hundred subjects were randomly selected and interviewed with the SCID, once by telephone and once in person (1-3 months later). FINDINGS. The prevalence of SAD assessed with the telephone interviews was 56%, whereas the in-person prevalence was 52%, with no statistically significant difference. The test-retest kappa for the 200 interviews was .84, indication of excellent agreement. PRACTICE IMPLICATIONS. These findings, along with the existing evidence of their validity, should encourage the use of SCID by telephone for SAD diagnostic interviews.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of modular home made capillary electrophoresis equipment with spectrophotometric detection, at a visible region by means of a miniaturized linear charge coupled device, was evaluated for the determination of four food dyes. This system presents a simple but efficient home made cell detection scheme. A computer program that converts the spectral data after each run into the electropherograms was developed to evaluate the analytical parameters. The dyes selected for analytical evaluation of the system were Brilliant Blue FCF, Fast Green FCF, Sunset Yellow FCF, and Amaranth. Separation was carried out in a 29cm length and 75 mu m I.D fused silica capillary, using 10mmolL-1 borate buffer at pH 9, with separation voltage of 7.5kV. The detection limits for the dyes were between 0.3 and 1.5mgL-1 and the method presented adequate linearity over the ranges studied, with correlation coefficients greater than 0.99. The method was applied for determination and quantification of these dyes in fruit juices and candies.