10 resultados para Sports facilities -- Automation

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study addressed the use of conventional and vegetable origin polyurethane foams to extract C. I. Acid Orange 61 dye. The quantitative determination of the residual dye was carried out with an UV/Vis absorption spectrophotometer. The extraction of the dye was found to depend on various factors such as pH of the solution, foam cell structure, contact time and dye and foam interactions. After 45 days, better results were obtained for conventional foam when compared to vegetable foam. Despite presenting a lower percentage of extraction, vegetable foam is advantageous as it is considered a polymer with biodegradable characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the predictive validity of the Braden Scale for Predicting Pressure Sore Risk in elderly residents of long-term care facilities (LTCFs) in Brazil. The determination of the cutoff score for the Brazilian population is important for the comparison between Brazilian and international studies and establishment of guidelines for prevention of pressure ulcers in our health care facilities. This is the first study of its kind in Brazil. This was a secondary analysis of a prospective cohort study conducted with 233 LTCF residents aged 60 and over who underwent complete skin examination and Braden Scale rating every 2 days for 3 months. Two groups of patients were considered: the total group (N = 233) and risk group (n = 94, total scores <= 18). Data from the first and last assessments were analyzed for sensitivity, specificity, and likelihood ratios. The best results were obtained for the total group, with cutoff scores of 18 and 17, sensitivity of 75.9% and 74.1%, specificity of 70.3% and 75.4%, and area under the receiver operating characteristic curve (AUC-ROC) of 0.79 and 0.81 at the first and last assessments, respectively. For the risk group, the cutoff scores of 16 (first assessment) and 13 (last assessment) were associated with a smaller AUC-ROC and, therefore, lower predictive accuracy. The Braden Scale showed good predictive validity in elderly LTCF residents. (Geriatr Nurs 2010;31:95-104)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study had as objective to verify the production of fight, martial arts and combat sports in articles published in the main Physical Education academic journals available in Brazil after the establishment of the CONFEF, as well as analyze the subjects studied in these articles. The subject classification followed Tani (1996)`s proposition concerning an academic structure to Kinesiology, Physical Education and Sport. When considering the 2561 articles published on these journals only 75 (2.93%) were related to Fight/Martial Arts/Combat Sports. It was verified a predominance of studies conducted in the Biodynamic area (40%), followed by Human Movement Socio-cultural Studies (32%) and Motor Behavior (8%). The applied studies were divided as: Human Movement Pedagogy (10.7%), Sports Training (8%), Sports Administration (1.3%) and Adapted Human Movement (none study published). These data indicate: (1) a reduced number of publications concerning these activities, especially those of applied nature; (2) a need to promote inter and multidisciplinary research about this subject.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power distribution automation and control are import-ant tools in the current restructured electricity markets. Unfortunately, due to its stochastic nature, distribution systems faults are hardly avoidable. This paper proposes a novel fault diagnosis scheme for power distribution systems, composed by three different processes: fault detection and classification, fault location, and fault section determination. The fault detection and classification technique is wavelet based. The fault-location technique is impedance based and uses local voltage and current fundamental phasors. The fault section determination method is artificial neural network based and uses the local current and voltage signals to estimate the faulted section. The proposed hybrid scheme was validated through Alternate Transient Program/Electromagentic Transients Program simulations and was implemented as embedded software. It is currently used as a fault diagnosis tool in a Southern Brazilian power distribution company.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study approaches the economic and technical evaluation of equivalent carbon dioxide (CO(2) eqv.) capture and storage processes, considered in a proposal case compared to a base case. The base case considers an offshore petroleum production facility, with high CO(2) content (4 vol%) in the composition of the produced gas and both CO(2) and natural gas emissions to the atmosphere, called CO(2) eqv. emissions. The results obtained with this study, by using a Hysys process simulator, showed a CO(2) emission reduction of 65% comparing the proposal case in relation to the base case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Petri net (PN) modeling is one of the most used formal methods in the automation applications field, together with programmable logic controllers (PLCs). Therefore, the creation of a modeling methodology for PNs compatible with the IEC61131 standard is a necessity of automation specialists. Different works dealing with this subject have been carried out; they are presented in the first part of this paper [Frey (2000a, 2000b); Peng and Zhou (IEEE Trans Syst Man Cybern, Part C Appl Rev 34(4):523-531, 2004); Uzam and Jones (Int J Adv Manuf Technol 14(10):716-728, 1998)], but they do not present a completely compatible methodology with this standard. At the same time, they do not maintain the simplicity required for such applications, nor the use of all-graphical and all-mathematical ordinary Petri net (OPN) tools to facilitate model verification and validation. The proposal presented here completes these requirements. Educational applications at the USP and UEA (Brazil) and the UO (Cuba), as well as industrial applications in Brazil and Cuba, have already been carried out with good results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The facilities location problem for companies with global operations is very complex and not well explored in the literature. This work proposes a MILP model that solves the problem through minimization of the total logistic cost. Main contributions of the model are the pioneer carrying cost calculation, the treatment given to the take-or-pay costs and to the international tax benefits such as drawback and added value taxes in Brazil. The model was successfully applied to a real case of a chemical industry with industrial plants and sales all over the world. The model application recommended a totally new sourcing model for the company.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Listeriosis is a serious foodborne disease caused by Listeria monocytogenes, a pathogen often found in food processing plants. Poultry meat and its derivatives may harbor L. monocytogenes even if good manufacturing practices are implanted in abattoirs. Little information exists in Brazil on the frequency of L. monocytogenes contamination, even though the country is considered the top poultry meat exporter in the world. This study attempted to compare 2 exporters poultry facilities following same the standards but differing only in manual (plant M) or automatic (plant A) evisceration. Eight hundred fifty-one samples from food, food contact and non-food contact surfaces, water, and workers` hands were collected from cage to finished products over a 1-yr period. In plant A, 20.1% of the samples were positive for L. monocytogenes, whereas in plant M, 16.4% was found. The greatest incidence of contamination with the pathogen in plant A was found in non- food contact surfaces (27.3%), while in plant M, it was found in products (19.4%). The most prevalent serovars were 1/2a or 3a (plant M) and 4b, 4d, or 4e (plant A). Despite having proper hygiene and good manufacturing practices, controlling the entry and persistence of L. monocytogenes in processing facilities remains a formidable task.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the two-level network design problem with intermediate facilities. This problem consists of designing a minimum cost network respecting some requirements, usually described in terms of the network topology or in terms of a desired flow of commodities between source and destination vertices. Each selected link must receive one of two types of edge facilities and the connection of different edge facilities requires a costly and capacitated vertex facility. We propose a hybrid decomposition approach which heuristically obtains tentative solutions for the vertex facilities number and location and use these solutions to limit the computational burden of a branch-and-cut algorithm. We test our method on instances of the power system secondary distribution network design problem. The results show that the method is efficient both in terms of solution quality and computational times. (C) 2010 Elsevier Ltd. All rights reserved.