3 resultados para Sistema de base

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the tissue compatibility of a silorane-based resin system (FiltekTM Silorane) and a methacrylate-based nanoparticle resin (FiltekTM Supreme XT) after implantation in the subcutaneous connective tissue of isogenic mice. One hundred and thirty five male isogenic BALB/c mice were randomly assigned to 12 experimental and 3 control groups, according to the implanted material and the experimental period of 7, 21 and 63 days. At the end of each period, the animals were killed and the tubes with the surrounding tissues were removed and processed for microscopic analysis. Samples were subjected to a descriptive and a semi-quantitative analyses using a 4-point scoring system (0-3) to evaluate the collagen fiber formation and inflammatory infiltrate. Data were statistically analyzed using the Kruskal Wallis test (?=0.05). The results showed that there was no significant difference between the experimental and control groups considering the three evaluation periods (p>0.05). The silorane-based and the methacrylate-based nanoparticle resins presented similar tissue response to that of the empty tube (control group) after subcutaneous implantation in isogenic mice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74ºC for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (α= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Considerando a importância do Sistema de Informações sobre Orçamentos Públicos em Saúde (SIOPS) como ferramenta para o planejamento, gestão e controle social dos gastos públicos em saúde, este trabalho teve como objetivo avaliar a relação entre a regularidade na alimentação do SIOPS e o conhecimento e uso do Sistema pelos gestores municipais do Estado de Pernambuco, Brasil. Foram selecionados dez municípios distribuídos nas cinco mesorregiões do estado, sendo cinco regulares e cinco irregulares na alimentação do Sistema, e aplicada uma entrevista semi-estruturada entre os secretários de saúde dos respectivos municípios. Com base na análise dos dados, foi identificado que o domínio de informática e o conhecimento do Sistema não interferem na regularidade da alimentação, em função do distanciamento entre os gestores das Secretarias de Saúde e o SIOPS, em geral alimentado por serviços terceirizados. Constata-se que as informações geradas não têm sido exploradas potencialmente pelos gestores enquanto instrumento de gestão.