9 resultados para Schuyler, Philippa Duke.

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To discuss and share knowledge around advances in the care of patients with thrombotic disorders, the Third International Symposium of Thrombosis and Anticoagulation was held in So Paulo, Brazil, from October 14-16, 2010. This scientific program was developed by clinicians for clinicians, and was promoted by four major clinical research institutes: the Brazilian Clinical Research Institute, the Duke Clinical Research Institute of the Duke University School of Medicine, the Canadian VIGOUR Centre, and the Uppsala Clinical Research Center. Comprising 3 days of academic presentations and open discussion, the symposium had as its primary goal to educate, motivate, and inspire internists, cardiologists, hematologists, and other physicians by convening national and international visionaries, thought-leaders, and dedicated clinician-scientists. This paper summarizes the symposium proceedings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ""CORE-64"" trial (""Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors""). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. Methods: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. Results: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. Conclusions: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of cross-sectional arc calcification on the diagnostic accuracy of computed tomography (CT) angiography compared with conventional coronary angiography for the detection of obstructive coronary artery disease (CAD). Materials and Methods: Institutional Review Board approval and written informed consent were obtained from all centers and participants for this HIPAA-compliant study. Overall, 4511 segments from 371 symptomatic patients (279 men, 92 women; median age, 61 years [interquartile range, 53-67 years]) with clinical suspicion of CAD from the CORE-64 multi-center study were included in the analysis. Two independent blinded observers evaluated the percentage of diameter stenosis and the circumferential extent of calcium (arc calcium). The accuracy of quantitative multidetector CT angiography to depict substantial (>50%) stenoses was assessed by using quantitative coronary angiography (QCA). Cross-sectional arc calcium was rated on a segment level as follows: noncalcified or mild (<90 degrees), moderate (90 degrees-180 degrees), or severe (>180 degrees) calcification. Univariable and multivariable logistic regression, receiver operation characteristic curve, and clustering methods were used for statistical analyses. Results: A total of 1099 segments had mild calcification, 503 had moderate calcification, 338 had severe calcification, and 2571 segments were noncalcified. Calcified segments were highly associated (P < .001) with disagreement between CTA and QCA in multivariable analysis after controlling for sex, age, heart rate, and image quality. The prevalence of CAD was 5.4% in noncalcified segments, 15.0% in mildly calcified segments, 27.0% in moderately calcified segments, and 43.0% in severely calcified segments. A significant difference was found in area under the receiver operating characteristic curves (noncalcified: 0.86, mildly calcified: 0.85, moderately calcified: 0.82, severely calcified: 0.81; P < .05). Conclusion: In a symptomatic patient population, segment-based coronary artery calcification significantly decreased agreement between multidetector CT angiography and QCA to detect a coronary stenosis of at least 50%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multiple endocrine neoplasia type 2 is characterized by germline mutations in RET. For exon 10, comprehensive molecular and corresponding phenotypic data are scarce. The International RET Exon 10 Consortium, comprising 27 centers from 15 countries, analyzed patients with RET exon 10 mutations for clinical-risk profiles. Presentation, age-dependent penetrance, and stage at presentation of medullary thyroid carcinoma (MTC), pheochromocytoma, and hyperparathyroidism were studied. A total of 340 subjects from 103 families, age 4-86, were registered. There were 21 distinct single nucleotide germline mutations located in codons 609 (45 subjects), 611 (50), 618 (94), and 620 (151). MTC was present in 263 registrants, pheochromocytoma in 54, and hyperparathyroidism in 8 subjects. Of the patients with MTC, 53% were detected when asymptomatic, and among those with pheochromocytoma, 54%. Penetrance for MTC was 4% by age 10, 25% by 25, and 80% by 50. Codon-associated penetrance by age 50 ranged from 60% (codon 611) to 86% (620). More advanced stage and increasing risk of metastases correlated with mutation in codon position (609-620) near the juxtamembrane domain. Our data provide rigorous bases for timing of premorbid diagnosis and personalized treatment/prophylactic procedure decisions depending on specific RET exon 10 codons affected. Hum Mutat 32:51-58, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oligodendrogliomas are the second most common malignant brain tumor in adults and exhibit characteristic losses of chromosomes 1p and 19q. To identify the molecular genetic basis for this alteration, we performed exomic sequencing of seven tumors. Among other changes, we found that the CIC gene (homolog of the Drosophila gene capicua) on chromosome 19q was somatically mutated in six cases and that the FUBP1 gene [encoding far-upstream element (FUSE) binding protein] on chromosome 1p was somatically mutated in two tumors. Examination of 27 additional oligodendrogliomas revealed 12 and 3 more tumors with mutations of CIC and FUBP1, respectively, 58% of which were predicted to result in truncations of the encoded proteins. These results suggest a critical role for these genes in the biology and pathology of oligodendrocytes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Recent studies indicate an increased frequency of mutations in the gene encoding glucocerebrosidase (GBA), a deficiency of which causes Gaucher`s disease, among patients with Parkinson`s disease. We aimed to ascertain the frequency of GBA mutations in an ethnically diverse group of patients with Parkinson`s disease. Methods Sixteen centers participated in our international, collaborative study: five from the Americas, six from Europe, two from Israel, and three from Asia. Each center genotyped a standard DNA panel to permit comparison of the genotyping results across centers. Genotypes and phenotypic data from a total of 5691 patients with Parkinson`s disease (780 Ashkenazi Jews) and 4898 controls (387 Ashkenazi Jews) were analyzed, with multivariate logistic-regression models and the Mantel-Haenszel procedure used to estimate odds ratios across centers. Results All 16 centers could detect two GBA mutations, L444P and N370S. Among Ashkenazi Jewish subjects, either mutation was found in 15% of patients and 3% of controls, and among non-Ashkenazi Jewish subjects, either mutation was found in 3% of patients and less than 1% of controls. GBA was fully sequenced for 1883 non-Ashkenazi Jewish patients, and mutations were identified in 7%, showing that limited mutation screening can miss half the mutant alleles. The odds ratio for any GBA mutation in patients versus controls was 5.43 across centers. As compared with patients who did not carry a GBA mutation, those with a GBA mutation presented earlier with the disease, were more likely to have affected relatives, and were more likely to have atypical clinical manifestations. Conclusions Data collected from 16 centers demonstrate that there is a strong association between GBA mutations and Parkinson`s disease.