59 resultados para Safety Device Attitudes.
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
This study investigated the consumer attitude to food irradiation in Sao Paulo, Brazil, through a qualitative research perspective. Three focus groups were conducted with 30 consumers, responsible for food choices and purchases. Both irradiated and nonirradiated food samples were served in the sessions to motivate the discussion and elicit the participants knowledge, opinions, feelings and concerns towards the irradiation process. Reactions were similar among the groups and differences between the irradiated and the nonirradiated samples were hardly perceived. When provided with positive information about irradiation and its benefits to foods and human health, many people still remained suspicious about the safety of the technology. Risk perception seemed to be related to unease and lack of knowledge about nuclear power and its non-defense use. Participants claimed for more transparency in communication about risks and benefits of irradiated foods to the human health, especially with respect to the continued consumption. Industrial relevance: Irradiation is an emerging food processing technology, which has been gaining interest by food technologists, producers and manufacturers all over the world in the last decades. Irradiation is suitable for disinfestation, microorganism load reduction or sterilization, assuring the safety, as well as having benefits in the shelf-life of foodstuffs. Food irradiation is approved in many countries and its use in food processing is endorsed by several reputed authorities, such as FAD and USDA. Despite the approval and recommendation, this technology still remains underutilized not only in Brazil, but also in other countries. The main reason appears to be the consumer concerns and doubts about the use of radiations in food processing. To develop communication strategies in promotion of irradiated foods it is necessary to investigate consumer attitudes, knowledge. opinions, as well as fears, with respect to the use of radiation in food processing. It is well-known that consumer views on technology may vary from a culture to another. So, findings from consumer research in a country may certainly not reflect the consumer views in other countries. In this sense, Brazilian studies focused on consumer views on food irradiation are necessary to gain understanding on how the local market accepts the technology. Brazil is one of the most important food producers in the world and an emerging consumer market with a population of about 184 million people. Food irradiation is regulated in Brazil since 1973, but to date only a few food ingredients are subjected to irradiation. The wide use of irradiation in food processing would favor Brazilian producers in the quality and safety assurance of food products, both for the local market and for exports. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Aim To describe the perceptions and attitudes of registered nurses (RNs) towards adverse events (AEs) in nursing care. Background The professionals` subjective perspectives should be taken into account for the prevention of AEs in care settings. Method Schutz`s social phenomenology was developed. Interviews were conducted with nine Intensive Care Unit RNs. Results The following five descriptive categories emerged: (1) the occurrence of AEs is inherent to the human condition but provokes a feeling of insecurity, (2) the occurrence of AEs indicates the existence of failures in health care systematization, (3) the professionals` attitudes towards AEs should be permeated by ethical principles; (4) the priority regarding AEs should be the mitigation of harm to patients, and (5) decisions regarding the communication of AEs were determined by the severity of the error. Conclusions The various subjective perspectives related to the occurrence of AEs requires a health care systematization with a focus on prevention. Ethical behaviour is essential for the patients` safety. Implications for nursing management Activities aimed at the prevention of AEs should be integrated jointly with both the professionals and the health care institution. A culture of safety, not punishment, and improvement in the quality of care provided to patients should be priorities.
Resumo:
This study aimed to evaluate the attitudes towards food safety among consumers in the city of So Paulo, the major consumer market in Brazil. Focus group sessions were conducted with 30 adults responsible for food choices and purchases. Results indicated a preference for supermarkets over street markets, for the variety of foods, convenience and confidence in the safety assurance. On the other hand, the ""naturalness"" of the products in the street markets was the main reason for purchases in those places. Participants showed concerns with respect to food additives, hormones and pesticides - technological rather than ""natural"" hazards. Minimally processed and ready-to-eat foods were considered convenient products meeting the need for time/labor-savings in the kitchen, although suspicion about wholesomeness and safety came up among consumers. Lack of awareness regarding potentially risky behaviors was observed, including handling and storage of foods in the domestic environment. In conclusion, this study suggests that Brazilian regulators should create more effective risk communication combining technical information with actual consumer perceptions of food risks. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Introduction: Pediatric percutaneous renal biopsy (Bx) is a routine procedure in pediatric nephrology to obtain renal tissues for histological study. We evaluated the safety, efficacy, indications and renal findings of this procedure at a tertiary care pediatric university hospital and compared our findings with the literature. Methods: Retrospective study based on medical records from January 1993 to June 2006. Results: In the study period, 305 Bx were performed in 262 patients, 127 (48.5%) male, aged 9.8 +/- 4.2 years. A 16-gauge needle was utilized in 56/305 Bx, an 18-gauge needle in 252/305 Bx (82.6%). 56.1% Bx were performed under sedation plus local anesthesia, 43.9% under general anesthesia. The number of punctures per Bx was 3.1 +/- 1.3. Minor complications occurred in 8.6% procedures. The 16-gauge needle caused a higher frequency of renal hematomas (p = 0.05). The number of glomeruli per puncture was >= 5 in 96.7% and >= 7 in 92%. Glomeruli number per puncture and frequency of complications were not different according to the type of anesthesia used. A renal pathology diagnosis was achieved in 93.1% Bx. The main indications of Bx were nephrotic syndrome (NS), lupus nephritis (LN) and hematuria (HE). The diagnosis of minimal change disease (MCD) (61.3%), class V (35.6%) and IgA nephropathy (26.3%) predominated in NS, LN and HE patients, respectively. Conclusion: Pediatric real-time ultrasound-guided percutaneous renal biopsy was safe and effective. The main clinical indications for Bx were NS and LN, the predominant renal pathology diagnoses were MCD and class V LN.
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.
Resumo:
Background: The effects of etonogestrel (ETG)-releasing contraceptive implant during the immediate postpartum period on maternal safety are unknown. Study design: Forty healthy women exclusively breastfeeding were randomized to receive either ETG-releasing implant 24-48 h after delivery (n=20) or depot medroxyprogesterone acetate (DMPA group; n=20) at the sixth week postpartum. We measured blood pressure, maternal and neonatal weight, body mass index (BMI; kg/m(2)), waist circumference (WC), complete blood count, C-reactive protein, interleukin-6, tumor necrosis factor (TNF-alpha), lipid profile, fasting serum glucose and maintenance of exclusive lactation up to the 12th week postpartum. Results: Decreases in mean maternal weight, BMI (kg/m(2)) and WC were significantly greater in the ETG-releasing implant group than in the MPA group during the first 6 weeks postpartum (-4.64 +/- 2.71 kg vs. -2.6 +/- 2.45 kg mean +/- SD, p=.017; -1.77 +/- 1.06 kg/m(2) vs. -0.97 +/- 0.95 kg/m(2), p=.026; -15.3 +/- 6.72 cm vs. -9.05 +/- 5.84 cm, p=.003, respectively). In addition, total cholesterol and HDL, were lower in DMPA users, and TNF-alpha and leukocytes were higher in DMPA users compared to in the implant group, between 6 and 12 weeks after delivery. The newborns of implant users showed a trend towards gaining more weight, as compared with the infants of the DMPA mothers during the first 6 weeks of life (implant group: +1460.50 +/- 621.34 g vs. DMPA group: +1035.0 +/- 562.43 g, p=.05). The remaining variables, including the duration of exclusive breastfeeding, were similar between the groups. Conclusion: The insertion of ETG-releasing contraceptive implant during the immediate postpartum period was not associated with deleterious maternal clinical effects or with significant maternal metabolic alterations or decreased infant weight gain. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.
Resumo:
Current scientific knowledge provides clear evidence that alcohol-based mouthwashes can be beneficial in a daily oral health routine, including dental hygiene and plaque control. Several issues are worth discussing, in spite of the wealth of supporting evidence. Despite some undesirable effects to some people, like burning sensation, and some contraindications, like the use by infants, alcohol addicts and patients with mucosal injuries, there is no reason to avoid the use of alcohol-containing mouthwashes as long as they are used following proper guidance by dental professionals and the manufacturers' instructions. The alleged correlation between oral cancer and alcohol-based mouthrinses presents so little, weak, inconsistent and even contradictory evidence in the literature that any kind of risk warning to patients would be uncalled for. Antimicrobial mouthrinses are safe and effective in reducing plaque and gingivitis, and should be part of a comprehensive oral health care regimen that includes brushing, flossing and rinsing to prevent or minimize periodontal disease.
Resumo:
Purpose: Potentially Inappropriate Medications (PIM) use in elderly people may be responsible for the development of Adverse Drug Reaction (ADR) which, when severe, leads to hospital admissions. Objectives: to estimate the prevalence of elderly who had used PIM before being admitted to hospital and to identify the risk factors and the hospitalizations related to ADR arising from PIM. Methods: A descriptive and cross-sectional study was performed in the internal medicine ward of a teaching hospital (Brazil), in 2008. With the aid of a validated form, patients aged >= 60 years, with length of hospital stay >= 24 hours, were interviewed about drugs taken prior to the hospital admission and the complaints/reasons for hospitalization. Results: 19.1% (59/308) of older patients had taken PIM before hospital admission and in 4.9%; there were a causal relation between the PIM taken and the complaint reported. PIM responsible for admissions were: amiodarone, amitriptyline, cimetidine, clonidine, diazepam, digoxin, estrogen, fluoxetine, lorazepam, short-acting nifedipine and propranolol. 47.0% of the clinical manifestations of PIM-related ADR were: dizziness, fatigue, digoxin toxicity and erythema. Only polypharmacy was detected as a risk factor for the occurrence of ADR of PIM (p = 0.02). Conclusion: PIM use in elderly people is not a risk factor for ADR-related hospital admission. Probably, severe ADR, which lead to hospitalizations of older people, can be explained by idiosyncratic response or the predisposition of these patients to develop adverse drug events, whether or not drugs are classed as PIM.
Resumo:
The objective of this manuscript is to discuss the existing barriers for the dissemination of medical guidelines, and to present strategies that facilitate the adaptation of the recommendations into clinical practice. The literature shows that it usually takes several years until new scientific evidence is adopted in current practice, even when there is obvious impact in patients' morbidity and mortality. There are some examples where more than thirty years have elapsed since the first case reports about the use of a effective therapy were published until its utilization became routine. That is the case of fibrinolysis for the treatment of acute myocardial infarction. Some of the main barriers for the implementation of new recommendations are: the lack of knowledge of a new guideline, personal resistance to changes, uncertainty about the efficacy of the proposed recommendation, fear of potential side-effects, difficulties in remembering the recommendations, inexistence of institutional policies reinforcing the recommendation and even economical restrains. In order to overcome these barriers a strategy that involves a program with multiple tools is always the best. That must include the implementation of easy-to-use algorithms, continuous medical education materials and lectures, electronic or paper alerts, tools to facilitate evaluation and prescription, and periodic audits to show results to the practitioners involved in the process. It is also fundamental that the medical societies involved with the specific medical issue support the program for its scientific and ethical soundness. The creation of multidisciplinary committees in each institution and the inclusion of opinion leaders that have pro-active and lasting attitudes are the key-points for the program's success. In this manuscript we use as an example the implementation of a guideline for venous thromboembolism prophylaxis, but the concepts described here can be easily applied to any other guideline. Therefore, these concepts could be very useful for institutions and services that aim at quality improvement of patient care. Changes in current medical practice recommended by guidelines may take some time. However, if there is a broader participation of opinion leaders and the use of several tools listed here, they surely have a greater probability of reaching the main objectives: improvement in provided medical care and patient safety.
Resumo:
Dengue, the most common arbovirus infection globally, is transmitted by mosquito vectors. Healthcare-related transmission, including transmission by blood products, has been documented, although the frequency of these occurrences is unknown. Dengue is endemic to Singapore, a city-state in Asia. Using mathematical modeling, we estimated the risk for dengue-infected blood transfusions in Singapore in 2005 to be 1.625-6/10,000 blood transfusions, assuming a ratio of asymptomatic to symptomatic infections of 2:1 to 10:1. However, the level of viremia required to cause clinical dengue cases is person-dependent and unknown. Further studies are needed to establish the magnitude of the threat that dengue poses to blood safety in countries where it is endemic. It will then be possible to assess whether screening is feasible and to identify approaches that are most cost-effective on the basis of characteristics of local populations and seasonality of dengue.
Resumo:
An in vivo study was conducted to verify the ability of laser fluorescence (LF) to assess the activity status of occlusal caries in primary teeth, using different air-drying times. Occlusal sites (707) were examined using LF (DIAGNOdent) after air-drying for 3 s and 15 s, and the difference between readings (DIF15 s-3 s) was calculated. For concurrent validation of LF, visual criteria-Nyvad (NY) and Lesion Activity Assessment associated with the International Caries Detection and Assessment System (LAA-ICDAS)-were the reference standards for lesion activity. Histological exam using a pH-indicator dye (0.1% methyl red) was performed in 46 exfoliated/extracted teeth for criterion validation. LF readings and DIF15 s-3 s were compared using Kruskall-Wallis and Mann-Whitney tests. Receiver operating characteristic analyses were performed and validity parameters calculated, considering the caries activity assessment. Using NY, active lesions (3 s: 30.0 +/- 29.3; 15 s: 34.2 +/- 30.6) presented higher LF readings than inactive lesions (3 s: 17.0 +/- 16.3; 15 s: 19.2 +/- 17.3; p <0.05), different from LAA-ICDAS. Active cavitated caries resulted in higher LF readings (3 s: 50.3 +/- 3.5; 15 s: 54.7 +/- 30.2) than inactive cavitated caries (3 s: 19.9 +/- 16.3; 15 s: 22.8 +/- 16.8). Therefore, LF can distinguish cavitated active and inactive lesions classified by NY, but not by LAA-ICDAS; however, this difference might be related to the visual system rather than to LF. The air-drying time could be an alternative to improve the caries activity assessment; however, longer air-drying time is suggested to be tested subsequently. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3463007]
Resumo:
An analysis of the experimental conditions under which low-frequency (70-150 kHz) Alfven eigertmodes (AE) are excited during the monster sawtooth in Joint European Torus [F Romanelli et al, Proceedings of the 22nd IAEA Fusion Energy Conference, Geneva, Switzerland, 2008] is presented for the specific case of a discharge with ion cyclotron heating (5 MW) Using a simplified AE model for modes excited at the Alfven wave continuum maximum with geodesic corrections taken into account, the temporal evolution of the value of the safety factor q(0) at the magnetic axis is determined We describe a new scheme to determine the time variation of q(0) that works under conditions in which other standard diagnostics, such as the motional Stark effect do not give reliable results such as during a monster sawtooth [doi 10 1063/1 3494212]
Resumo:
We investigate the electronic properties of Mn(B) substitutional doping in cubic boron nitride (BN), for different charge states, using density functional theory (DFT) calculations. We show that the neutral Mn has a nonmagnetic ground state (S=0). Upon charge injection, it is unambiguously shown that the Mn(B)(-) has a high-spin configuration with a strong, localized magnetic moment of 5 mu(Bohr). We developed a simple model, parameterized by the DFT results, that allows us to interpret the rules played by the crystal-field and exchange-correlation splitting in the magnetization process.
Resumo:
We report a highly efficient switch built from an organic molecule assembled between single-wall carbon nanotube electrodes. We theoretically show that changes in the distance between the electrodes alter the molecular conformation within the gap, affecting in a dramatic way the electronic and charge transport properties, with an on/off ratio larger than 300. This opens up the perspective of combining molecular electronics with carbon nanotubes, bringing great possibilities for the design of nanodevices.