71 resultados para Reactor water clean-up
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Extraction and clean-up are essential points in polycyclic aromatic hydrocarbon (PAHs) analysis in a solid matrix. This work compares extraction techniques and clean-up procedures for PAH analysis. PAH levels, their toxicological significance and source were also evaluated in the waters of the Cocó and Ceará rivers. The efficiency of PAH recovery was higher for the soxhlet and ultrasonic techniques. PAH recovery varied from 69.3 to 99.3%. Total PAH concentration (ΣHPA) varied from 720.73 to 2234.76 µg kg-1 (Cocó river) and 96.4 to 1859.21 µg kg-1 (Ceará river). The main PAH sources are pyrolytic processes and the levels were classified as medium so that adverse effects are possible.
Resumo:
Use of activated charcoal and ion-exchange resin to cleaN up and concentrate enzymes in extracts from biodegraded wood. Ceriporiopsis subvermispora was used for the biodegradation of Eucalyptus grandis chips in the presence or absence of co-substrates (glucose and corn steep liquor) during 7, 14 and 28 days. Afterwards, the biodegraded chips were extracted with 50 mM sodium acetate buffer (pH 5.5) supplemented with 0.01% Tween 60. High activities of manganese peroxidases (MnPs) were observed in all the extracts, both in the absence (430, 765 and 896 UI kg(-1) respectively) and in the presence of co-substrates (1,013; 2,066 and 2,323 UI kg(-1) respectively). The extracts presented a high ratio between absorbances at 280 and 405 nm, indicating a strong abundance of aromatic compounds derived from lignin over heme-peroxidases. Adsorption into activated charcoal showed to be an adequate strategy to reduce the absorbance at 280 urn in all the extracts. Moreover, it allowed to maximize the capacity of an anion exchange resin bed (DEAE-Sepharose) used to concentrate the MnPs present in the extracts. It was concluded that the use of activated charcoal followed by adsorption into DEAE Sepharose is a strategy that can be used to concentrate MnPs in extracts obtained during the biodegradation of E. grandis by C. subvermispora.
Resumo:
A simple, rapid, and low-cost coulometric method for direct detection of glyphosate and aminomethylphosphonic acid (AMPA) in water samples using anion-exchange chromatography and coulometric detection with copper electrode is presented. Under optimized conditions, the limits of detection (LODs) (S/N = 3) were 0.038 mu g ml(-1) for glyphosate and 0.24 mu g ml(-1) for AMPA, without any preconcentration method. The calibration curves were linear and presented an excellent correlation coefficient. The method was successfully applied to the determination of glyphosate and AMPA in water samples without any kind of extraction, clean-up, or preconcentration step. No interferent was found in the water, like this, the recovery was, practically, 100%. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
An environmentally friendly analytical procedure with high sensitivity for determination of carbaryl pesticide in natural waters was developed. The flow system was designed with solenoid micro-pumps in order to improve mixing conditions and minimize reagent consumption as well as waste generation. A long pathlength (100 cm) flow cell based on a liquid core waveguide (LCW) was employed to increase the sensitivity in detection of the indophenol formed from the reaction between carbaryl and p-aminophenol (PAP). A clean-up step based on cloud-point extraction was explored to remove the interfering organic matter, avoiding the use of toxic organic solvents. A linear response was observed within the range 5-200 mu g L(-1) and the detection limit, coefficient of variation and sampling rate were estimated as 1.7 mu g L(-1) (99.7% confidence level), 0.7% (n=20) and 55 determinations per hour, respectively. The reagents consumption was 1.9 mu g of PAP and 5.7 mu g of potassium metaperiodate, with volume of 2.6 mL of effluent per determination. The proposed procedure was selective for the determination of carbaryl, without interference from other carbamate pesticides. Recoveries within 84% and 104% were estimated for carbaryl spiked to water samples and the results obtained were also in agreement with those found by a batch spectrophotometric procedure at the 95% confidence level. The waste of the analytical procedure was treated with potassium persulphate and ultraviolet irradiation, yielding a colorless residue and a decrease of 94% of total organic carbon. In addition, the residue after treatment was not toxic for Vibrio fischeri bacteria. (c) 2010 Elsevier B.V. All rights reserved.
Resumo:
An improved procedure is proposed for determination of the pesticide carbaryl in natural waters based on double cloud point extraction. The clean up step was carried out only with Triton X-114 in alkaline medium in order to avoid the use of toxic organic solvents as well as to minimise waste generation. Cloud point preconcentration of the product of the reaction of the analyte with p-aminophenol and cetyltrimethylammonium bromide was explored to increase sensitivity and improve the detection limit. Linear response was achieved within 10 and 500 mu g L-1 and the apparent molar absorptivity was estimated as 4.6 x 105 L mol-1 cm-1. The detection limit was estimated as 7 mu g L-1 at the 99.7% confidence level and the coefficient of variation was 3.4% (n = 8). Recoveries within 91 and 99% were estimated for carbaryl spiked water samples. The results obtained for natural water samples were in agreement with those achieved by the batch of spectrophotometric procedure at the 95% confidence level. The proposed procedure is then a simple, fast, inexpensive and greener alternative for carbaryl determination.
Resumo:
This paper describes the development, electrochemical characterization and utilization of a cobalt phthalocyanine (CoPc), modified multi-walled carbon nanotube (MWCNT), and paraffin composite electrode for the quantitative determination of epinephrine (EP) in human urine samples. The electrochemical profile of the proposed composite electrode was analyzed by differential pulse voltammetry (DPV) that showed a shift of the oxidation peak potential of EP at 175 mV to less positive value, compared with a paraffin/graphite composite electrode without CoPc. DPV experiments in PBS at pH 6.0 were performed to determine EP without any previous step of extraction, clean-up, and derivatization, in the range from 1.33 to 5.50 mu mol L(-1), with a detection limit of 15.6 nmol L(-1) (2.86) of EP in electrolyte prepared with purified water. The lifetime of the proposed sensors was at least over 1000 determinations with 1.7 and 3.1 repeatability and reproducibility relative standard deviations, respectively. Human urine samples without any purification step were successfully analyzed under the standard addition method using paraffin/MWCNT/CoPc composite electrode. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A ocorrência de aflatoxina B1 (AFB1) em rações e aflatoxina M1 (AFM1) no leite cru foi avaliada em propriedades leiteiras situadas na região nordeste do Estado de São Paulo, Brasil, de outubro de 2005 a fevereiro de 2006. A análise de aflatoxinas foi efetuada utilizando-se colunas de imunoafinidade para purificação dos extratos, sendo a quantificação realizada através de cromatografia líquida de alta eficiência. A AFB1 foi detectada em 40% das rações em níveis de 1,0 a 19,5 μg.kg-1. A concentração de AFM1 em 36,7% de amostras de leite positivas variou de 0,010 a 0,645 μg.L-1. Somente uma amostra de leite estava acima do limite de tolerância adotado no Brasil (0,5 μg.L-1) para AFM1. Concluiu-se que as concentrações de aflatoxinas na ração e no leite foram relativamente baixas, embora a alta frequência das aflatoxinas nas amostras analisadas indique a necessidade de contínuo monitoramento a fim de prevenir a contaminação de ingredientes e rações destinadas ao gado leiteiro.
Resumo:
ABSTRACT Microphysical and thermodynamical features of two tropical systems, namely Hurricane Ivan and Typhoon Conson, and one sub-tropical, Catarina, have been analyzed based on space-born radar PR measurements available on the TRMM satellite. The procedure to classify the reflectivity profiles followed the Heymsfield et al (2000) and Steiner et al (1995) methodologies. The water and ice content have been calculated using a relationship obtained with data of the surface SPOL radar and PR in Rondonia State in Brazil. The diabatic heating rate due to latent heat release has been estimated using the methodology developed by Tao et al (1990). A more detailed analysis has been performed for Hurricane Catarina, the first of its kind in South Atlantic. High water content mean value has been found in Conson and Ivan at low levels and close to their centers. Results indicate that hurricane Catarina was shallower than the other two systems, with less water and the water was concentrated closer to its center. The mean ice content in Catarina was about 0.05 g kg-1 while in Conson it was 0.06 g kg-1 and in Ivan 0.08 g kg-1. Conson and Ivan had water content up to 0.3 g kg-1 above the 0ºC layer, while Catarina had less than 0.15 g kg-1. The latent heat released by Catarina showed to be very similar to the other two systems, except in the regions closer to the center.
Resumo:
A hydrodynamic characterization of the Itapocu river and Barra Velha lagoon estuarine system was carried out with the objective of evaluating how the current regime in this area is affected by astronomical and meteorological tides and the river discharge. Meteorological, water level and current velocity and direction data were gathered hourly during a twenty-day period, from 22-July until 10-August, 2004. Current meters were positioned at the inlet, at the entrance of the north and south lagoons and at the lower estuary of the river along with a tide gauge. The estuarine system showed distinct current behavior among the different sectors within the estuary, responding to the different forcings. The strongest currents were observed at the inlet while the weakest values were observed at the northern lagoon, a location that showed little dynamic. The general flow was ebb-dominated flux, in response to fluvial discharge, even during local wind water set-up event.
Resumo:
Organic markers, such as sterols and ketones, were used to assess sewage contamination in sediments from the Santos Bay, SP, and its continental shelf. These compounds were analyzed by GC/FID after soxhlet extraction, clean up and derivatization. The concentration of coprostanol and ratios between selected sterols were used to evaluate fecal contamination. The stations located in the mid-western part of the Santos Bay presented organic matter from sewage due to the input of fecal material from the city of Santos by submarine sewage outfall. Stations located at the continental shelf did not present fecal contamination. Coprostanol levels in sewage outfall stations were higher in comparison to other Brazilian coastal areas, except Guanabara Bay/RJ, and could be related to the fraction of the population without sewage treatment.
Resumo:
An analytical procedure based on microwave-assisted digestion with diluted acid and a double cloud point extraction is proposed for nickel determination in plant materials by flame atomic absorption spectrometry. Extraction in micellar medium was successfully applied for sample clean up, aiming to remove organic species containing phosphorous that caused spectral interferences by structured background attributed to the formation of PO species in the flame. Cloud point extraction of nickel complexes formed with 1,2-thiazolylazo-2-naphthol was explored for pre-concentration, with enrichment factor estimated as 30, detection limit of 5 mu g L(-1) (99.7% confidence level) and linear response up to 80 mu g L(-1). The accuracy of the procedure was evaluated by nickel determinations in reference materials and the results agreed with the certified values at the 95% confidence level.
Resumo:
The transfer of carbon (C) from Amazon forests to aquatic ecosystems as CO(2) supersaturated in groundwater that outgases to the atmosphere after it reaches small streams has been postulated to be an important component of terrestrial ecosystem C budgets. We measured C losses as soil respiration and methane (CH(4)) flux, direct CO(2) and CH(4) fluxes from the stream surface and fluvial export of dissolved inorganic C (DIC), dissolved organic C (DOC), and particulate C over an annual hydrologic cycle from a 1,319-ha forested Amazon perennial first-order headwater watershed at Tanguro Ranch in the southern Amazon state of Mato Grosso. Stream pCO(2) concentrations ranged from 6,491 to 14,976 mu atm and directly-measured stream CO(2) outgassing flux was 5,994 +/- A 677 g C m(-2) y(-1) of stream surface. Stream pCH(4) concentrations ranged from 291 to 438 mu atm and measured stream CH(4) outgassing flux was 987 +/- A 221 g C m(-2) y(-1). Despite high flux rates from the stream surface, the small area of stream itself (970 m(2), or 0.007% of watershed area) led to small directly-measured annual fluxes of CO(2) (0.44 +/- A 0.05 g C m(2) y(-1)) and CH(4) (0.07 +/- A 0.02 g C m(2) y(-1)) per unit watershed land area. Measured fluvial export of DIC (0.78 +/- A 0.04 g C m(-2) y(-1)), DOC (0.16 +/- A 0.03 g C m(-2) y(-1)) and coarse plus fine particulate C (0.001 +/- A 0.001 g C m(-2) y(-1)) per unit watershed land area were also small. However, stream discharge accounted for only 12% of the modeled annual watershed water output because deep groundwater flows dominated total runoff from the watershed. When C in this bypassing groundwater was included, total watershed export was 10.83 g C m(-2) y(-1) as CO(2) outgassing, 11.29 g C m(-2) y(-1) as fluvial DIC and 0.64 g C m(-2) y(-1) as fluvial DOC. Outgassing fluxes were somewhat lower than the 40-50 g C m(-2) y(-1) reported from other Amazon watersheds and may result in part from lower annual rainfall at Tanguro. Total stream-associated gaseous C losses were two orders of magnitude less than soil respiration (696 +/- A 147 g C m(-2) y(-1)), but total losses of C transported by water comprised up to about 20% of the +/- A 150 g C m(-2) (+/- 1.5 Mg C ha(-1)) that is exchanged annually across Amazon tropical forest canopies.
Resumo:
A multi-pumping flow system exploiting prior assay is proposed for sequential turbidimetric determination of sulphate and chloride in natural waters. Both methods are implemented in the same manifold that provides facilities for: in-line sample clean-up with a Bio-Rex 70 mini-column with fluidized beads: addition of low amounts of sulphate or chloride ions to the reaction medium for improving supersaturation; analyte precipitation with Ba(2+) or Ag(+); real-time decision on the need for next assay. The sample is initially run for chloride determination, and the analytical signal is compared with a preset value. If higher, the sample is run again, now for sulphate determination. The strategy may lead to all increased sample throughput. The proposed system is computer-controlled and presents enhanced figures of merit. About 10 samples are run per hour (about 60 measurements) and results are reproducible and Unaffected by the presence of potential interfering ions at concentration levels usually found in natural waters. Accuracy was assessed against ion chromatography. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
This survey evaluated the presence of AFM(1) in human urine samples from a specific Brazilian population, as well as corn, peanut, and milk consumption measured by two types of food inquiry. Urine samples from donors who live in the city of Piracicaba, State of Sao Paulo, Brazil were analyzed to detect the presence of aflatoxin M(1) (AFM(1)). an aflatoxin B(1) metabolite, which may be used as aflatoxin B(1) exposure biomarker. The AFM(1) analysis was performed using immunoaffinity clean-up and detection by high-performance-liquid chromatography with fluorescence detector. A total of 69 samples were analyzed and 45 of them (65%) presented contaminations >= 1.8 pg ml(-1), which was the limit of quantification (LOQ). Seventy eight percent (n = 54) of the samples presented detectable concentrations of AFM(1) (>0.6 pg ml(-1)). The AFM(1) concentration among samples above LOQ ranged from 1.8 to 39.9 pg ml(-1). There were differences in food consumption profile among donors, although no association was found between food consumption and AFM(1) concentration in urine. The high frequency of positive samples suggests exposure of the populations studied to aflatoxins. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
A simple and fast method is described for simultaneous determination of methylmercury (MeHg), ethylmercury (Et-Hg) and inorganic mercury (Ino-Hg) in blood samples by using capillary gas chromatography-inductively coupled plasma mass spectrometry (GC-ICP-MS) after derivatization and alkaline digestion. Closed-vessel microwave assisted digestion conditions with tetramethylammonium hydroxide (TMAH) have been optimized. Derivatization by using ethylation and propylation procedures have also been evaluated and compared. The absolute detection limits (using a 1 mu L injection) obtained by GC-ICP-MS with ethylation were 40 fg for MeHg and Ino-Hg, respectively, and with propylation were 50, 20 and 50 fg for MeHg, Et-Hg and Ino-Hg, respectively. Method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). Additional validation is provided based on the comparison of results obtained for mercury speciation in blood samples with the proposed procedure and with a previously reported LC-ICP-MS method. With the new proposed procedure no tedious clean-up steps are required and a considerable improvement of the time of analysis was achieved compared to other methods using GC separation.