6 resultados para RAINWATER

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the tropical town energy budget (t-TEB) scheme addressed to simulate the diurnal occurrence of the urban heat island (UHI) as observed in the Metropolitan Area of Rio de Janeiro (MARJ; -22A degrees S; -44A degrees W) in Brazil. Reasoning about the tropical urban climate have guided the scheme implementation, starting from the original equations from Masson (Bound-Lay Meteorol 94:357-397, 2000). The modifications include (a) local scaling approaches for obtaining flux-gradient relationships in the roughness sub-layer, (b) the Monin-Obukhov similarity framework in the inertial sub-layer, (c) increasing aerodynamic conductance toward more unstable conditions, and (d) a modified urban subsurface drainage system to transfer the intercepted rainwater by roofs to the roads. Simulations along 2007 for the MARJ are obtained and compared with the climatology. The t-TEB simulation is consistent with the observations, suggesting that the timing and dynamics of the UHI in tropical cities could vary significantly from the familiar patterns observed in mid-latitude cities-with the peak heat island intensity occurring in the morning than at night. The simulations are suggesting that the thermal phase shift of this tropical diurnal UHI is a response of the surface energy budget to the large amount of solar radiation, intense evapotranspiration, and thermal response of the vegetated surfaces over a very humid soil layer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The scavenging processes of chemical species have been previously studied with numerical modeling, in order to understand the gas and particulate matter intra-reservoir transferences. In this study, the atmospheric (RAMS) and scavenging (B.V.2) models were used, in order to simulate sulfate concentrations in rainwater using scavenging processes as well as the local atmospheric conditions obtained within the LBA Project in the State of Rondonia, during a dry-to-wet transition season. Two case studies were conducted. The RAMS atmospheric simulation of these events presented satisfactory results, showing the detailed microphysical processes of clouds in the Amazonian region. On the other hand, with cloud entrainments, observed values have been overestimated. Modeled sulfate rainwater concentration, using exponential decay and cloud heights of 16 km and no entrainments, presented the best results, reaching 97% of the observed value. The results, using shape parameter 5, are the best, improving the overall result. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The seasonal evolution of daily and hourly values of global and diffuse solar radiation at the surface are compared for the cities of Sao Paulo and Botucatu, both located in Southeast Brazil and representative of urban and rural areas, respectively. The comparisons are based on measurements of global and diffuse solar irradiance carried out at the surface during a six year simultaneous period in these two cities. Despite the similar latitude and altitude, the seasonal evolution of daily values indicate that Sao Paulo receives, during clear sky days, 7.8% less global irradiance in August and 5.1% less in June than Botucatu. On the other hand, Sao Paulo receives, during clear sky days, 3.6% more diffuse irradiance in August and 15.6% more in June than Botucatu. The seasonal variation of the diurnal cycle confirms these differences and indicates that they are more pronounced during the afternoon. The regional differences are related to the distance from the Atlantic Ocean, systematic penetration of the sea breeze and daytime evolution of the particulate matter in Sao Paulo. An important mechanism controlling the spatial distribution of solar radiation, on a regional scale, is the sea breeze penetration in Sao Paulo, bringing moisture and maritime aerosol that in turn further increases the solar radiation scattering due to pollution and further reduces the intensity of the direct component of solar radiation at the surface. Surprisingly, under clear sky conditions the atmospheric attenuation of solar radiation in Botucatu during winter - the biomass burning period due to the sugar cane harvest - is equivalent to that at Sao Paulo City, indicating that the contamination during sugar cane harvest in Southeast Brazil has a large impact in the solar radiation field at the surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increased surface area of copper electrodes upon applying a suitable potential protocol was characterized by atomic force microscopy images. Scanning electrochemical microscopy was used to demonstrate the enhanced reactivity of the generated surface. The modified electrode showed excellent catalytic activity towards nitrite reduction in acidic medium (pH 2). This new platform was used in the development of a fast and simple voltammetric method for nitrite determination. Commercial and rainwater spiked samples were analyzed and the data showed an excellent agreement with those obtained with a reference spectrophotometric method (Griess reaction) at a confidence level of 95% (Student`s t-test).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A fast and robust analytical method for amperometric determination of hydrogen peroxide (H(2)O(2)) based on batch injection analysis (BIA) on an array of gold microelectrodes modified with platinum is proposed. The gold microelectrode array (n = 14) was obtained from electronic chips developed for surface mounted device technology (SMD), whose size offers advantages to adapt them in batch cells. The effect of the dispensing rate, volume injected, distance between the platinum microelectrodes and the pipette tip, as well as the volume of solution in the cell on the analytical response were evaluated. The method allows the H(2)O(2) amperometric determination in the concentration range from 0.8 mu mol L(-1) to 100 mu mol L(-1). The analytical frequency can attain 300 determinations per hour and the detection limit was estimated in 0.34 mu mol L(-1) (3 sigma). The anodic current peaks obtained after a series of 23 successive injections of 50 mu L of 25 mu mol L(-1) H(2)O(2) showed an RSD < 0.9%. To ensure the good selectivity to detect H(2)O(2), its determination was performed in a differential mode, with selective destruction of the H(2)O(2) with catalase in 10 mmol L(-1) phosphate buffer solution. Practical application of the analytical procedure involved H(2)O(2) determination in rainwater of Sao Paulo City. A comparison of the results obtained by the proposed ampermetric method with another one which combines flow injection analysis (FIA) with spectrophotometric detection showed good agreement. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensor for H2O2 amperometric detection based on a Prussian blue (PB) analogue was developed. The electrocatalytic process allows the determination of hydrogen peroxide at 0.0 V with a limit of detection of 1.3 mu mol L-1 in a flow injection analysis (FIA) configuration. Studies on the optimization of the FIA parameters were performed and under optimal FIA operational conditions the linear response of the method was extended up to 500 mu mol L-1 hydrogen peroxide with good stability. The possibility of using the developed sensor in medium containing sodium ions and the increased operational stability constitute advantages in comparison with PB-based amperometric sensors. The usefulness of the methodology was demonstrated by addition-recovery experiments with rainwater samples and values were in the 98.8 to 103% range.