41 resultados para Qualidade superficial
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
This study evaluated the superficial microhardness of enamel in teeth at different posteruptive ages (before eruption in the oral cavity, 2-3 years after eruption, 4-10 years after eruption and more than 10 years after eruption). The study sample was composed of 134 specimens of human enamel. One fragment of each tooth was obtained from the flattest central portion of the crown to produce specimens with 3 x 3 mm. The enamel blocks were minimally flattened out and polished in order to obtain a flat surface parallel to the base, which is fundamental for microhardness testing. Microhardness was measured with a microhardness tester and a Knoop diamond indenter, under a static load of 25 g applied for 5 seconds. Comparison between the superficial microhardness obtained for the different groups was performed by analysis of Student's t test. The results demonstrated that superficial microhardness values have a tendency to increase over the years, with statistically significant difference only between unerupted enamel and that with more than 10 years after eruption. According to the present conditions and methodology, it was concluded that there were differences between the superficial micro-hardness of specimens at different eruptive ages, revealing an increasing mineralization. However, this difference was significant only between unerupted specimens and those with more than 10 years after eruption.
Resumo:
O objetivo deste trabalho foi determinar as características de qualidade da carne de suínos de diferentes linhagens genéticas, em diferentes pesos de abate. Neste estudo foram utilizados 88 suínos por linhagem, fêmeas e machos castrados, com idade e peso médio iniciais de 74 dias e 30kg, respectivamente, pertencentes a três linhagens genéticas distintas, designadas de AgroceresPic, Dalland e Seghers. A etapa experimental foi dividida em quatro fases (Crescimento I, Crescimento II, Terminação I e Terminação II). Ao final de cada etapa, foram abatidos 60 animais (10 por linhagem/sexo), para as análises de qualidade da carne. O pH e a temperatura foram determinados a 1 e 24 horas post mortem. Foram retiradas amostras para as determinações de cor, perda de água por exsudação (PAE), perda de água por cocção (PAC) e força de Cisalhamento. As amostras provenientes das carcaças dos animais da linhagem AgroceresPic e Dalland apresentaram valores médios de PAE superiores aos da linhagem Seghers. Os valores médios de PAC foram diferentes entre as diferentes fases. Na fase Crescimento II, as carnes provenientes das carcaças das fêmeas Dalland foram mais duras, ou seja, com maiores valores de força de cisalhamento, que as carnes dos machos. Entretanto, na linhagem Seghers, as carnes dos machos foram mais duras. Observou-se diferença de L* entre os sexos da linhagem AgroceresPic nas fases Terminação I e II e, na linhagem Dalland, na Terminação II. As linhagens Dalland e Seghers apresentaram carnes com resultados superiores de a*, parâmetro característico da cor vermelha (a*>0). Pode-se concluir, portanto, que as características de qualidade da carne de suínos (pH, perda de água por exsudação, cor e maciez) podem variar entre grupos genéticos, entre sexos e entre diferentes pesos ao abate.
Resumo:
Foram avaliados os efeitos dos níveis de metionina e lisina sobre o desempenho e a qualidade interna e externa dos ovos de poedeiras comerciais. Foram utilizadas 256 poedeiras Hisex White com 68 semanas de idade, alojadas individualmente em delineamento inteiramente casualizado em arranjo fatorial 4 õ 4, com quatro níveis de lisina (0,482; 0,682; 0,882 e 1,082%) e metionina (0,225; 0,318; 0,411 e 0,505%), totalizando 16 dietas, cada uma com quatro repetições de quatro aves. O desempenho foi avaliado por meio das características consumos de ração, lisina, metionina, proteína bruta e de energia, peso, produção e massa de ovos e conversão alimentar. A qualidade interna dos ovos foi avaliada por meio das características peso e porcentagem de albúmen e gema e pela unidade Haugh. As aves apresentaram máxima produção de ovos quando alimentadas com rações contendo 0,444% de metionina total e 0,872% de lisina total. A classificação dos ovos por tipo e as características de qualidade interna e externa dos ovos não foram influenciadas pelos níveis de metionia e lisina da dieta.
Resumo:
O experimento foi conduzido para avaliar os efeitos de rações com diferentes níveis de proteína bruta (PB) e lisina sobre as características de desempenho, a qualidade interna dos ovos e o balanço/retenção do nitrogênio. Foram utilizadas 160 poedeiras Hisex White com 48 semanas de idade, alojadas individualmente em delineamento inteiramente casualizado em esquema fatorial 4 × 2, com quatro níveis de PB (12, 14, 16 e 18%) e dois de lisina (0,85 e 1,00%), totalizando oito rações com cinco repetições de quatro aves. O consumo de proteína bruta, o peso dos ovos, a massa de ovos e a porcentagem de albúmen apresentam resposta linear crescente aos níveis de PB na dieta. O balanço de nitrogênio não é alterado pelos níveis de proteína das rações.
Resumo:
Technical evaluation of analytical data is of extreme relevance considering it can be used for comparisons with environmental quality standards and decision-making as related to the management of disposal of dredged sediments and the evaluation of salt and brackish water quality in accordance with CONAMA 357/05 Resolution. It is, therefore, essential that the project manager discusses the environmental agency's technical requirements with the laboratory contracted for the follow-up of the analysis underway and even with a view to possible re-analysis when anomalous data are identified. The main technical requirements are: (1) method quantitation limits (QLs) should fall below environmental standards; (2) analyses should be carried out in laboratories whose analytical scope is accredited by the National Institute of Metrology (INMETRO) or qualified or accepted by a licensing agency; (3) chain of custody should be provided in order to ensure sample traceability; (4) control charts should be provided to prove method performance; (5) certified reference material analysis or, if that is not available, matrix spike analysis, should be undertaken and (6) chromatograms should be included in the analytical report. Within this context and with a view to helping environmental managers in analytical report evaluation, this work has as objectives the discussion of the limitations of the application of SW 846 US EPA methods to marine samples, the consequences of having data based on method detection limits (MDL) and not sample quantitation limits (SQL), and present possible modifications of the principal method applied by laboratories in order to comply with environmental quality standards.
Resumo:
OBJETIVO: Verificar e comparar os efeitos da hidrocinesioterapia e da cinesioterapia na qualidade de vida de pacientes portadoras de fibromialgia. MATERIAIS E MÉTODOS: Foi realizado um ensaio clínico randomizado, cego, para os avaliadores. Para avaliar a qualidade de vida, utilizou-se o questionário genérico SF-36 a fim de analisar os aspectos físicos e psicológicos em 24 pacientes do sexo feminino, portadoras de fibromialgia, com idade de 30 a 55 anos, alocadas aleatoriamente em dois grupos: hidrocinesioterapia e cinesioterapia. Durante um período de 23 semanas, as pacientes foram submetidas a alongamentos e exercícios aeróbios de baixa intensidade com duração de uma hora cada sessão (em ambos os grupos). RESULTADOS: Observou-se melhora estatisticamente significante (p < 0,05) na maior parte dos aspectos abordados pelo SF-36 em ambos os grupos. CONCLUSÃO: A hidrocinesioterapia promoveu um relaxamento muscular favorável para a melhora da qualidade de vida, porém, não foi o fator principal para amenizar os efeitos da patologia, uma vez que a cinesioterapia também proporcionou efeitos benéficos para a promoção do bem-estar dessas pacientes. Portanto, os alongamentos e os exercícios aeróbios de baixa intensidade empregados em ambos os protocolos são os prováveis responsáveis pelos efeitos benéficos observados nas duas modalidades terapêuticas analisadas.
Resumo:
OBJETIVO: este estudo teve como objetivo comparar a qualidade de vida e as áreas do desempenho ocupacional de pacientes epilépticos antes e doze meses após tratamento cirúrgico. METODOLOGIA: a amostra foi composta por 30 pacientes epilépticos que frequentavam o Centro de Cirurgia de Epilepsia da Faculdade de Medicina de São José do Rio Preto - FAMERP. Todos os participantes responderam a uma entrevista semiestruturada para coleta de dados sociodemográficos, ao Questionário de Qualidade de Vida em Epilepsia - 31 (QOLIE-31) e à Medida Canadense de Desempenho Ocupacional - MCDO. RESULTADOS: dezenove pacientes(63,3%) eram do sexo feminino e onze (36,7%) do sexo masculino, com idade entre 22 e 65 anos (42,1±11,9). Os resultados obtidos com o QOLIE-31 apontaram diferenças significativas em seis dos sete domínios que compõe o questionário quando comparados o período pré e pós-cirúrgico. A comparação dos resultados da COPM mostrou aumento significativo tanto na performance quanto na satisfação dos pacientes com suas atividades de vida diária, instrumentais de vida diária e de lazer. CONCLUSÃO: o tratamento cirúrgico se mostrou eficaz na melhora da qualidade de vida e no desempenho ocupacional o que pode traduzir-se a médio e longo prazo em integração social mais adequada para os pacientes epilépticos.
Resumo:
OBJECTIVE: To analyze household risk factors associated with high lead levels in surface dental enamel. METHODS: A cross-sectional study was conducted with 160 Brazilian adolescents aged 14-18 years living in poor neighborhoods in the city of Bauru, southeastern Brazil, from August to December 2008. Body lead concentrations were assessed in surface dental enamel acid-etch microbiopsies. Dental enamel lead levels were measured by graphite furnace atomic absorption spectrometry and phosphorus levels were measured by inductively coupled plasma optical emission spectrometry. The parents answered a questionnaire about their children's potential early (05 years old) exposure to well-known lead sources. Logistic regression was used to identify associations between dental enamel lead levels and each environmental risk factor studied. Social and familial covariables were included in the models. RESULTS: The results suggest that the adolescents studied were exposed to lead sources during their first years of life. Risk factors associated with high dental enamel lead levels were living in or close to a contaminated area (OR = 4.49; 95% CI: 1.69;11.97); and member of the household worked in the manufacturing of paints, paint pigments, ceramics or batteries (OR = 3.43; 95% CI: 1.31;9.00). Home-based use of lead-glazed ceramics, low-quality pirated toys, anticorrosive paint on gates and/or sale of used car batteries (OR = 1.31; 95% CI: 0.56;3.03) and smoking (OR = 1.66; 95% CI: 0.52;5.28) were not found to be associated with high dental enamel lead levels. CONCLUSIONS: Surface dental enamel can be used as a marker of past environmental exposure to lead and lead concentrations detected are associated to well-known sources of lead contamination.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
OBJETIVO: Avaliar a qualidade da informação registrada nas declarações de óbito fetal. MÉTODOS: Estudo documental com 710 óbitos fetais em hospitais de São Paulo, SP, no primeiro semestre de 2008, registrados na base unificada de óbitos da Fundação Sistema Estadual de Análise de Dados e da Secretaria de Estado da Saúde de São Paulo. Foi analisada a completitude das variáveis das declarações de óbito fetal emitidas por hospitais e Serviço de Verificação de Óbitos. Os registros das declarações de óbito de uma amostra de 212 óbitos fetais de hospitais do Sistema Único de Saúde foram comparados com os dados dos prontuários e do registro do Serviço de Verificação de Óbitos. RESULTADOS: Dentre as declarações de óbito, 75% foram emitidas pelo Serviço de Verificação de Óbitos, mais freqüente nos hospitais do Sistema Único de Saúde (78%). A completitude das variáveis das declarações de óbito emitidas pelos hospitais foi mais elevada e foi maior nos hospitais não pertencentes ao Sistema Único de Saúde. Houve maior completitude, concordância e sensibilidade nas declarações de óbito emitidas pelos hospitais. Houve baixa concordância e elevada especificidade para as variáveis relativas às características maternas. Maior registro das variáveis sexo, peso ao nascer e duração da gestação foi observada nas declarações emitidas no Serviço de Verificação de Óbitos. A autópsia não resultou em aprimoramento da indicação das causas de morte: a morte fetal não especificada representou 65,7% e a hipóxia intrauterina, 24,3%, enquanto nas declarações emitidas pelos hospitais foi de 18,1% e 41,7%, respectivamente. CONCLUSÕES: É necessário aprimorar a completitude e a indicação das causas de morte dos óbitos fetais. A elevada proporção de autópsias não melhorou a qualidade da informação e a indicação das causas de morte. A qualidade das informações geradas de autópsias depende do acesso às informações hospitalares.
Resumo:
O artigo visa analisar a concentração de fluoreto na água para consumo humano, considerando o balanço entre benefícios e riscos à saúde, e produzir subsídios para atualização da legislação brasileira. Estudos de revisão sistemática, documentos oficiais e dados meteorológicos foram examinados. As temperaturas nas capitais brasileiras indicam que o fluoreto deveria variar de 0,6 a 0,9 mg/L para prevenir cárie dentária. Concentração de fluoreto natural de 1,5 mg/L é tolerável para consumo no Brasil se não houver tecnologia de custo-benefício aceitável para ajuste/remoção do seu excesso. A ingestão diária de água com fluoreto em concentração > 0,9 mg/L representa risco à dentição em menores de oito anos de idade e os consumidores deveriam ser expressamente informados desse risco. Considerando a expansão do programa nacional de fluoretação da água para regiões de clima tipicamente tropical, deve-se revisar a Portaria 635/75, relacionada ao fluoreto adicionado às águas de abastecimento público.
Resumo:
OBJETIVO: Comparar duas abordagens baseadas em critérios do Quality Assessment of Diagnostic Accuracy Studies (QUADAS) e do Standards for Reporting Studies of Diagnostic Accuracy (STARD) na avaliação de qualidade de estudos de validação do teste rápido OptiMal®, para diagnóstico de malária. MÉTODOS: Foi realizada busca de artigos de validação do teste rápido na base bibliográfica Medline acessada pelo PubMed, no ano de 2007. Treze artigos foram recuperados na busca. Foram combinados 12 critérios do QUADAS e três do STARD para comparação com os critérios do QUADAS isoladamente. Foi considerado que artigos de regular a boa qualidade atenderiam pelo menos 50% dos critérios do QUADAS. RESULTADOS: Dos 13 artigos recuperados, 12 cumpriram pelo menos 50% dos critérios do QUADAS, e apenas dois atenderam à combinação dos critérios. Considerando-se a combinação dos dois critérios (> 6 QUADAS e > 3STARD), dois estudos (15,4%) apresentaram boa qualidade metodológica. A seleção de artigos usando a combinação proposta variou de dois a oito artigos, dependendo do número de itens considerados como ponto de corte. CONCLUSÕES: A combinação do QUADAS com o STARD tem o potencial de conferir maior rigor nas avaliações da qualidade de artigos publicados sobre validação de testes diagnósticos em malária, por incorporar a checagem de informações relevantes não alcançáveis pelo uso do QUADAS isoladamente.
Resumo:
Objetivou-se avaliar os fatores demográficos, sócio-econômicos e de estilo de vida associados à qualidade da dieta de adultos residentes na Região Metropolitana de São Paulo, Brasil. Estudo transversal, por meio de inquérito domiciliar, de base populacional, foi realizado no Distrito do Butantã e nos municípios de Itapecerica da Serra, Embu e Taboão da Serra. Utilizaram-se dados de um questionário e um recordatório de 24 horas de 1.840 adultos de 20 anos ou mais, de ambos os sexos, incluídos em um inquérito de saúde (ISA-SP). A qualidade da dieta foi avaliada através do índice de qualidade da dieta (IQD) adaptado para a realidade local. Utilizou-se análise de regressão linear para avaliar a associação entre o IQD e as demais variáveis. A maioria da população (75%) apresentou dieta que necessita de melhora. Observaram-se médias baixas para os componentes: frutas, verduras e legumes, leite e derivados. Número de bens de consumo duráveis, escolaridade do chefe da família e ter 60 anos ou mais se associaram ao IQD em homens. Para as mulheres, a faixa etária se associou ao IQD. Em ambos os modelos, o consumo de calorias se manteve como variável de ajuste.
Resumo:
OBJETIVO: Avaliar a qualidade nutricional das refeições servidas em uma Unidade de Alimentação e Nutrição de uma fábrica da região metropolitana da cidade de São Paulo. MÉTODOS: Dentre os cardápios praticados no período de um ano (242 dias) na unidade mencionada, foram selecionados 30% por sorteio sistemático, e avaliados utilizando-se o Índice de Qualidade da Refeição, com base nas recomendações da Organização Mundial da Saúde e do Ministério da Saúde brasileiro. Esse índice compõe-se de cinco itens que variam entre zero e 20 pontos cada um: adequação na oferta de hortaliças e frutas; oferta de carboidratos; oferta de gordura total; oferta de gordura saturada e variabilidade do cardápio. No período analisado, foram servidas 367 preparações, agrupadas em 30 categorias, segundo composição e forma de preparo. A correlação de Spearman foi utilizada para investigar a correlação do índice com os nutrientes da refeição. As análises foram realizadas no pacote estatístico STATA, considerando-se o nível de significância de 5%. RESULTADOS: O valor médio do Índice de Qualidade da Refeição foi de 64,60 (DP=21,18) pontos, sendo 44% das refeições classificadas como "refeição que necessita de melhora" e apenas 25% como "adequadas". Além do arroz e do feijão, servidos diariamente, as preparações mais frequentes foram: legumes e frutas (30%), massas e cremes (12%), frituras (9%) e sobremesas com creme (8%). Encontrou-se correlação positiva entre o Índice de Qualidade da Refeição e a vitamina C (r=0,32). CONCLUSÃO: Apesar da presença constante de frutas, legumes e verduras, há a necessidade de adequar a oferta das preparações às recomendações para uma alimentação saudável, que efetivamente colaborem na promoção da saúde.
Resumo:
OBJETIVO: Avaliar o comportamento alimentar de mulheres com câncer de mama submetidas à quimioterapia, e sua relação com a qualidade de vida destas pacientes. MÉTODOS: A partir de um ensaio clínico do tipo antes e depois, selecionou-se 25 mulheres do Hospital AC Camargo (São Paulo, Brasil) durante o período de outubro de 2005 a abril de 2006. As pacientes inclusas no estudo apresentavam diagnóstico de câncer de mama, com estadiamento I e II e indicação de tratamento quimioterápico adjuvante. Nos momentos T0 (antes) e T1 (após o tratamento quimioterápico), o comportamento alimentar (consumo e aversão alimentar) foi avaliado por três recordatórios 24 horas e um questionário Food Action, respectivamente. A qualidade de vida foi monitorada por meio do questionário Functional Assessment of Cancer Therapy-Breast. RESULTADOS: Após o tratamento quimioterápico (T1), o consumo de macro e micronutrientes não apresentou alterações significantes, mas o consumo de frutas e sucos aumentou (p=0,03). Perfil inverso foi observado em relação à preferência por café preto (p=0,01) e pelo grupo de bebidas (p<0,001). Alimentos gordurosos (38%), laticínios (23%), café preto (15%), chá (15%), chocolate (7%) e carne vermelha (7%) foram os principais alimentos associados ao desconforto das pacientes. Análises de qualidade de vida mostraram que o tratamento quimioterápico promoveu significante redução no bem estar físico (p<0,01). Após o mesmo, algumas variáveis do comportamento alimentar foram significantemente correlacionadas com os parâmetros de qualidade de vida. CONCLUSÃO: A relação bilateral entre comportamento alimentar e qualidade de vida foi modificada negativamente pelo tratamento quimioterápico.