98 resultados para Pulse repetition frequency
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Objective: To assess the influence of energy and pulse repetition rate of Er:YAG laser on the enamel ablation ability and substrate morphology. Methods: Fifteen crowns of molars were sectioned in four fragments, providing 60 samples, which were ground to flatten the enamel surface. The initial mass was obtained by weighing the fragments. The specimens were hydrated for I h, fixed, and a 3-mm-diameter area was delimited. Twelve groups were randomly formed according to the combination of laser energies (200, 250, 300, or 350 mJ) and pulse repetition rates (2, 3, or 4 Hz). The final mass was obtained and mass loss was calculated by the difference between the initial and final mass. The specimens were prepared for SEM. Data were submitted to ANOVA and Scheffe test. Results: The 4 Hz frequency resulted in higher mass loss and was statistically different from 2 and 3 Hz (p < 0.05). The increase of frequency produced more melted areas, cracks, and unselective and deeper ablation. The 350 mJ energy promoted greater mass loss, similar to 300 mJ. Conclusions: The pulse repetition rate influenced more intensively the mass loss and morphological alteration. Among the tested parameters, 350 mJ/3 Hz improved the ability of enamel ablation with less surface morphological alterations. (C) 2007 Wiley Periodicals, Inc. J Biomed Mater Res.
Resumo:
Objective: The purpose of this study was to assess the efficacy of Er:YAG laser energy for composite resin removal and the influence of pulse repetition rate on the thermal alterations occurring during laser ablation. Materials and Methods: Composite resin filling was placed in cavities (1.0 mm deep) prepared in bovine teeth and the specimens were randomly assigned to five groups according to the technique used for composite filling removal. In group I (controls), the restorations were removed using a high-speed diamond bur. In the other groups, the composite fillings were removed using an Er: YAG laser with different pulse repetition rates: group 2-2 Hz; group 3-4 Hz; group 4-6 Hz; and group 5-10 Hz. The time required for complete removal of the restorative material and the temperature changes were recorded. Results: Temperature rise during composite resin removal with the Er: YAG laser occurred in the substrate underneath the restoration and was directly proportional to the increase in pulse repetition rate. None of the groups had a temperature increase during composite filling removal of more than 5.6 degrees C, which is considered the critical point above which irreversible thermal damage to the pulp may result. Regarding the time for composite filling removal, all the laser-ablated groups (except for group 5 [10 Hz]) required more time than the control group for complete elimination of the material from the cavity walls. Conclusion: Under the tested conditions, Er: YAG laser irradiation was efficient for composite resin ablation and did not cause a temperature increase above the limit considered safe for the pulp. Among the tested pulse repetition rates, 6 Hz produced minimal temperature change compared to the control group (high-speed bur), and allowed composite filling removal within a time period that is acceptable for clinical conditions.
Resumo:
The study evaluated the in vitro influence of pulse-repetition rate of Er:YAG laser and dentin depth on tensile bond strength of dentin-resin interface. Dentin surfaces of buccal or lingual surfaces from human third molars were submitted to tensile test in different depths (superficial, 1.0 and 1.5 mm) of the same dental area, using the same sample. Surface treatments were acid conditioning solely (control) and Er:YAG laser irradiation (80 mJ) followed by acid conditioning, with different pulse-repetition rates (1, 2, 3, or 4 Hz). Single bond/Z-250 system was used. The samples were stored in distilled water at 37 degrees C for 24 h, and then the first test (superficial dentine) was performed. The bond failures were analyzed. Following, the specimens were identified, grounded until 1.0- and 1.5-mm depths, submitted again to the treatments and to the second and, after that, to third-bond tests on a similar procedure and failure analysis. ANOVA and Tukey test demonstrated a significant difference (p < 0.001) for treatment and treatment X depth interaction (p < 0.05). The tested depths did not show influence (p > 0.05) on the bond strength of dentin-resin interface. It may be concluded that Er:YAG laser with 1, 2, 3, or 4 Hz combined with acid conditioning did not increase the resin tensile bond strength to dentin, regardless of dentin depth. (C) 2007 Wiley Periodicals, Inc.
Resumo:
Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.
Resumo:
Os efeitos da estimulação ultra-sônica sobre a consolidação óssea têm sido demonstrados por trabalhos experimentais e clínicos. Este estudo teve por objetivo investigar a aplicação clínica do ultra-som pulsado de baixa intensidade como tratamento adjuvante de fraturas diafisárias em cães. Foram utilizados 16 cães de raças variadas, com faixa etária entre sete meses e seis anos, peso corpóreo entre 2,5 e 43kg, portadores de fraturas diafisárias fechadas recentes localizadas no rádio e ulna, fêmur ou tíbia e fíbula, estabilizadas por procedimentos de osteossíntese (fixação esquelética externa, pinos intramedulares ou a associação desses métodos). Os cães foram divididos em dois grupos: fraturas estabilizadas tratadas por ultra-som de baixa intensidade (grupo tratado, n=8); fraturas estabilizadas, não tratadas por estimulação ultra-sônica, (grupo controle, n=8). Os animais foram avaliados por exames clínicos e radiográficos nos períodos pré-operatório, pós-operatório imediato e a cada 30 dias posteriores aos procedimentos cirúrgicos. Realizou-se tratamento com ultra-som pulsado (sinal senoidal com freqüência de 1,5MHz, largura de pulso de 200µs e freqüência de repetição de 1kHz) de baixa intensidade (30mW cm-2), aplicado de modo estacionário no foco de fratura. A terapia ultra-sônica foi realizada 20 minutos por dia, durante 21 dias consecutivos, a partir do período compreendido entre o 1° e o 9° dia pós-operatório. O teste t de Student, empregado na análise estatística, mostrou diferença significante (P<0,001 e alfa=0,05) entre as médias dos parâmetros de tempo para consolidação óssea observadas nos animais dos grupos tratado (média de 67,5 dias) e controle (média de 106 dias). Este protocolo de estimulação ultra-sônica promoveu sinais clínicos e radiográficos acelerados da consolidação óssea nas fraturas tratadas. Os resultados deste estudo sugerem que o ultra-som pulsado de baixa intensidade pode ser indicado como terapia adjuvante de fraturas diafisárias recentes em cães.
Resumo:
Objective: The purpose of this study was to evaluate the ablation capacity of different energies and pulse repetition rates of Er:YAG laser energy on primary molar enamel, by assessing mass loss and by analyzing the surface morphology with scanning electron microscopy. Background Data: Previous studies have demonstrated the capacity of the Er:YAG laser to ablate enamel substrate. Methods: Forty-two sound primary molars were bisected in a mesiodistal direction. The enamel surfaces were flattened and their initial mass (in milligrams) was obtained. An area of 4 mm(2) was delimited. The specimens were randomly assigned to 12 groups according to the combination of energy (160, 200, 250, and 300 mJ) and pulse repetition rate (2, 3, and 4 Hz). Er: YAG laser irradiation was performed on each specimen for 20 sec. After irradiation, the final mass was obtained and specimens were prepared for examination with scanning electron microscopy. The data obtained by subtracting the final mass from the initial mass were statistically analyzed using ANOVA and the Tukey test (p < 0.05). Results: The pulse repetition rate of 4 Hz provided greater mass loss, different from that seen with 2 Hz, and similar to that seen with 3 Hz. The energy level of 300 mJ resulted in greater mass loss, similar to that seen with 200 and 250 mJ. Scanning electron photomicrographs showed that there was non-selective enamel removal, with fused and cracked areas in all specimens. Conclusion: The parameters of 200 mJ and 2 Hz produced a good ablation rate with fewer surface alterations in primary molar enamel.
Resumo:
This paper presents the results of the in-depth study of the Barkhausen effect signal properties for the plastically deformed Fe-2%Si samples. The investigated samples have been deformed by cold rolling up to plastic strain epsilon(p) = 8%. The first approach consisted of time-domain-resolved pulse and frequency analysis of the Barkhausen noise signals whereas the complementary study consisted of the time-resolved pulse count analysis as well as a total pulse count. The latter included determination of time distribution of pulses for different threshold voltage levels as well as the total pulse count as a function of both the amplitude and the duration time of the pulses. The obtained results suggest that the observed increase in the Barkhausen noise signal intensity as a function of deformation level is mainly due to the increase in the number of bigger pulses.
Resumo:
Considering the increase in esthetic restorative materials and need for improvement in unsatisfactory restoration substitution with minimal inadvertent removal of healthy tissues, this study assessed the efficacy of erbium:yttrium-aluminum-garnet (Er:YAG) laser for composite resin removal and the influence of pulse repetition rate on the morphological analyses of the cavity by scanning electron microscope. Composite resin fillings were placed in cavities (1.0 mm deep) prepared in bovine teeth, and the 75 specimens were randomly assigned to five groups according to the technique used for composite filling removal (high-speed diamond bur, group I, as a control, and Er:YAG laser, 250 mJ output energy and 80 J/cm(2) energy density, using different pulse repetition rates: group II, 2 Hz; group III, 4 Hz; group IV, 6 Hz; group V, 10 Hz). After the removal, the specimens were split in the middle, and we analyzed the surrounding and deep walls to check for the presence of restorative material. The estimation was qualitative. The surfaces were examined with a scanning electron microscope. The results revealed that the experimental groups presented bigger amounts of remaining restorative material. The scanning electron microscopy (SEM) analyses showed irregularities of the resultant cavities of the experimental groups that increased proportionally with increase in repetition rate.
Resumo:
Objective: To evaluate the potential of 980-nm gallium aluminum arsenide (GaAlAs) and 1064-nm neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers to reduce bacteria after irradiation of implant surfaces contaminated with Enterococcus faecalis and Porphyromonas gingivalis and on irradiated implant surface morphology. Background: Despite the frequency of implant success, some implant loss is related to peri-implantitis because of difficulty in eliminating the biofilm. Methods: Implants (3.75 x 13 mm) with machined surfaces, surfaces sand blasted with titanium oxide (TiO(2)), and sand-blasted and acid-etched surfaces were exposed to P. gingivalis and E. faecalis cultures and irradiated with 980-nm GaAlAs or 1064-nm Nd: YAG lasers. After laser treatments, the number of remaining colony-forming units and implant surface morphology were analyzed using scanning electron microscopy (SEM). Results: The Nd: YAG laser was able to promote a total contamination reduction on all implants irradiated. The results with the GaAlAs laser showed 100% bacteria reduction on the implants irradiated with 3 W. Irradiation with 2.5 W and 3 W achieved 100% of bacteria reduction on P. gingivalis-contaminated implants. Decontamination was not complete for the sand-blasted TiO(2) (78.6%) and acid-etched surfaces (49.4%) contaminated with E. faecalis and irradiated with 2.5 W. SEM showed no implant surface changes. Conclusion: The wavelengths used in this research provided bacteria reduction without damaging implant surfaces. New clinical research should be encouraged for the use of this technology in the treatment of peri-implantitis.
Resumo:
CONTEXT: Mothers recall early-onset constipation in children attending gastroenterology clinics. OBJECTIVES: To study the bowel habit of young children in the community to determine, first, whether early-onset constipation is confirmed in this setting and, second, the agreement between recalled and recorded bowel habit. METHODS:Defecation data of 57 children aged 6.0-40.7 mo were obtained by maternal recall (questionnaire on predominant stool characteristics) and by record (1,934 defecations registered prospectively at home and in the nursery). The bowel habit was classified according to stool frequency and proportion of stool characteristics (soft, hard and/or runny). Two criteria were used to classify recorded data, since the cutoff point for hard stools to identify constipation is undefined in children: predominant criterion and adult criterion, respectively with >50% and >25% of stools with altered consistency. Bowel habit categories were: adequate, constipation, functional diarrhea and "other bowel habit". Nonparametric statistics, and the Kappa index for agreement between recalled and recorded bowel habit, were used. RESULTS: Constipation occurred in 17.5%, 10.5%, 19.3% of the children by recall, the predominant and the adult criteria, respectively. Constipation was the main recalled alteration, vs 12.3% "other bowel habit". Only one child classified as having functional diarrhea (by the adult criterion). Agreement between recalled and recorded bowel habit was fair for constipation, by the predominant and the adult criteria (K = 0.28 and 0.24, respectively), but only slight (K <0.16) for other bowel habit categories. Individual data, however, pointed to a better relationship between recalled constipation and the adult rather than the predominant criterion. CONCLUSIONS: Frequent early-onset constipation was confirmed. Fair agreement between recalled and recorded constipation by the two used criteria indicates that recalled data are quite reliable to detect constipation.
Resumo:
The aim of this study was to validate the intake of carotenoids, fruits and vegetables estimated by the Food Frequency Questionnaire for Adolescents (FFQA) using the method of triads. Blood samples were collected from 80 elementary school adolescents to assess serum levels of β-carotene. Partial correlation coefficients (r) were calculated between an estimated intake of carotenoids, fruits and vegetables and the serum levels of β-carotene. Validity coefficients were calculated using the method of triads. With the exception of carotenoids, partial r from the food frequency questionnaire (FFQ) were greater than those of the 24-hour recall (24hR). The fruit/vegetable group showed the highest partial r for the FFQ (r = 0.235) and the 24hR (r = 0.137). The highest validity coefficient was obtained for the vegetable group, as assessed by the FFQ (r = 0.873). On average, the validity coefficient values for the FFQ were greater than those obtained for the 24hR or the β-carotene serum levels. The FFQA is an accurate tool for estimating the intake of carotenoids, fruits and vegetables in this population group.
Resumo:
This study describes the validity of a food frequency questionnaire (FFQ) in 93 low-income women (20-65 years), participating in a case-control study in São Paulo, Brazil. Two FFQ (FFQ1 and FFQ2, 12 months apart) and three 24-hour dietary recalls (24hR) were conducted between 2003 and 2004 to estimate dietary intake during the past year. The Pearson correlation coefficients (crude, energy-adjusted and de-attenuated) were used for comparisons between FFQ and 24hR. The agreement between the methods was further examined by the Bland-Altman analysis. For the assessment of long-term reliability, the energy-adjusted intra-class correlation coefficients were mostly around 0.40, but higher for vitamin A and folate (0.50-0.56). Energy-adjusted, attenuation-corrected Pearson validity correlations between FFQ and DR ranged from 0.30-0.54 for macronutrients to 0.20-0.48 for micronutrients, with higher value for calcium (0.75). There were small proportions of grossly misclassified nutrient intakes, while Bland-Altman plots indicated that the FFQ is accurate in assessing nutrient intake at a group level.
Resumo:
A case-control study was carried out in litters of 1 to 7-day-old piglets to identify the main infectious agents involved with neonatal diarrhea in pigs. Fecal samples (n=276) from piglets were collected on pig farms in the State of Rio Grande do Sul, Brazil, from May to September 2007. Litters with diarrhea were considered cases (n=129) and normal litters (n=147) controls. The samples were examined by latex agglutination test, PAGE, conventional isolating techniques, ELISA, PCR, and microscopic methods in order to detect rotavirus, bacterial pathogens (Escherichia coli, Clostridium perfringens type A and C, and Clostridium difficile), and parasites (Coccidian and Cryptosporidium spp.). Outbreaks of diarrhea were not observed during sampling. At least one agent was detected in fecal samples on 25 out of 28 farms (89.3%) and in 16 farms (57.1%) more than one agent was found. The main agents diagnosed were Coccidia (42.86%) and rotavirus (39.29%). The main agents identified in litters with diarrhea were Clostridium difficile (10.6%), Clostridium perfringens type A (8.8%) and rotavirus (7.5%); in control litters, Clostridium difficile (16.6%) and Coccidian (8.5%). Beta hemolytic Escherichia coli and Clostridium perfringens type C were not detected. When compared with controls, no agent was significantly associated with diarrhea in case litters. These findings stress the need for caution in the interpretation of laboratorial diagnosis of mild diarrhea in neonatal pigs, as the sole detection of an agent does not necessarily indicate that it is the cause of the problem.
Resumo:
Carrying out information about the microstructure and stress behaviour of ferromagnetic steels, magnetic Barkhausen noise (MBN) has been used as a basis for effective non-destructive testing methods, opening new areas in industrial applications. One of the factors that determines the quality and reliability of the MBN analysis is the way information is extracted from the signal. Commonly, simple scalar parameters are used to characterize the information content, such as amplitude maxima and signal root mean square. This paper presents a new approach based on the time-frequency analysis. The experimental test case relates the use of MBN signals to characterize hardness gradients in a AISI4140 steel. To that purpose different time-frequency (TFR) and time-scale (TSR) representations such as the spectrogram, the Wigner-Ville distribution, the Capongram, the ARgram obtained from an AutoRegressive model, the scalogram, and the Mellingram obtained from a Mellin transform are assessed. It is shown that, due to nonstationary characteristics of the MBN, TFRs can provide a rich and new panorama of these signals. Extraction techniques of some time-frequency parameters are used to allow a diagnostic process. Comparison with results obtained by the classical method highlights the improvement on the diagnosis provided by the method proposed.
Resumo:
This work deals with an improved plane frame formulation whose exact dynamic stiffness matrix (DSM) presents, uniquely, null determinant for the natural frequencies. In comparison with the classical DSM, the formulation herein presented has some major advantages: local mode shapes are preserved in the formulation so that, for any positive frequency, the DSM will never be ill-conditioned; in the absence of poles, it is possible to employ the secant method in order to have a more computationally efficient eigenvalue extraction procedure. Applying the procedure to the more general case of Timoshenko beams, we introduce a new technique, named ""power deflation"", that makes the secant method suitable for the transcendental nonlinear eigenvalue problems based on the improved DSM. In order to avoid overflow occurrences that can hinder the secant method iterations, limiting frequencies are formulated, with scaling also applied to the eigenvalue problem. Comparisons with results available in the literature demonstrate the strength of the proposed method. Computational efficiency is compared with solutions obtained both by FEM and by the Wittrick-Williams algorithm.