130 resultados para Power Doppler ultrasound
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Evaluate the distribution and variation of placental vascular indices according to gestational age and placental volume. From March to November 2007, three-dimensional (3D)-power Doppler ultrasound was performed in 295 normal pregnancies from 12 to 40 weeks of gestation. Using the same preestablished settings for all patients, power Doppler was applied to the placenta and placental Volume was obtained by the rotational technique (VOCAL(TM)). The 3D-power histogram was used to determine the placental vascular indices: vascularization index (VI), flow index (FI) and vascularization-flow index (VFI). The placental vascular indices were then plotted against gestational age and placental volume. All placental vascular indices showed constant distribution throughout gestation. A tendency for a reduction in placental vascular indices with increased placental volume was observed, but was only statistically significant when placental FI was considered (p < 0.05). All placental vascular indices estimated by 3D-power Doppler ultrasonography presented constant distribution throughout gestation, despite the increase in placental volume according to gestational age. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.
Resumo:
Objective: To evaluate the impact of systematic use of intraoperative Doppler ultrasound during microsurgical subinguinal varicocele repair. Design: Prospective clinical study. Setting: Andrology laboratory and male infertility section of the urology department of a tertiary care hospital. Patient(s): Two hundred and thirteen men with clinical varicocele. Intervention(s): Subinguinal microsurgical varicocele ligation using an intraoperative vascular Doppler flow detector. Main Outcome Measure(s): Number of veins ligated, lymphatic spared, arteries identified or accidentally ligated. Result(s): A statistically significant greater number of arteries were identified and preserved when intraoperative vascular Doppler was used. In addition, the average number of internal spermatic veins ligated was statistically significantly greater in the same group. Accidental artery ligation occurred in two cases (1.1%) in which the Doppler was not applied. There was no statistically significant difference in number of lymphatics spared between groups. Conclusion(s): Our findings showed that concomitant use of intraoperative vascular Doppler during microsurgical varicocelectomy allows more arterial branches to be preserved, and more internal spermatic veins are likely to be ligated. This device should be considered an attractive tool to improve surgical outcomes and safety. (Fertil Steril (R) 2010; 93: 2396-9. (C)2010 by American Society for Reproductive Medicine.)
Resumo:
The aim of this study was to evaluate the arterial and venous blood flow in women who underwent upper limb axillary dissection surgery for the treatment of breast cancer. Sixty women were divided into two groups: group 1 (G1)-30 women who underwent breast surgery with axillary dissection level II or III (55.6 +/- A 8.6 years); group 2 (G2)-control, 30 women with no breast cancer (57.4 +/- A 7.0 years). Blood flow profile was evaluated by a continuous wave ultrasound Doppler device (Nicolet Vascular Versalab SE(A (R))) with an 8 MHz probe. Axillary, brachial arteries and veins, arm circumference, volumes, and the ankle-brachial index (ABI) were examined. Wilcoxon test and Mann-Whitney tests were applied to analyze blood flow velocity intra-group and between G1 and G2, respectively. The G1 results showed no lymphedema and no peripheral arterial disease (ABI > 0.9). Moreover, the mean blood flow velocity of the vessels ipsilateral to the surgery was significantly higher than the contralateral ones for all vessels examined (P < 0.05). The mean velocity of blood flow of the vessels contralateral to surgery was significantly higher than the axillary artery in G2 (P < 0.05). It can be concluded that women who underwent axillary dissection due to breast cancer showed probable stenosis in the arterial and venous axillary and brachial vessels of the upper limb ipsilateral to the surgery, confirmed by the increase of blood flow velocity, and such obstruction might affect the limb contralateral to the operation site.
Resumo:
The objective of this study was to describe multiple Doppler ultrasound parameters of ductus venosus and inferior vena cava in fetuses at gestational ages ranging from 22 to 38 weeks. In this prospective observational study, Doppler ultrasound exams were performed in 45 healthy fetuses at 22, 26, 34, and 38 weeks. Maximum venous velocity, minimum venous velocity, venous pulsatility index, and venous acceleration time (VAT) (defined as the time between minimum and maximum venous velocity) were evaluated at those gestational periods. Increase in the velocities and decrease in the pulsatility index were observed in these vessels throughout gestational age. The VAT increased with gestational age. The VAT, a Doppler parameter still not described elsewhere, increased during pregnancy could be related to a longer period of time needed to fill the atrium in bigger hearts. In this study, we provide reference values for VAT in healthy fetuses.
Resumo:
Methods currently employed to establish the etiology of congenital hypothyroidism include thyroid ultrasound and scintigraphic exams. Thyroglobulin is a protein almost exclusively secreted by thyroid tissue and indirectly reflects the amount of follicular cells. Even though thyroglobulin is easy to measure, it has been not frequently used because of discordant results to distinguish mainly athyreosis and ectopy (dysgenesis). Knowing the differences in inheritance and prognosis of thyroid dysgenesis and dyshormonogenesis, it is important to define the etiology of CH, combining tools that are easy, fast and available in most medical centers. Our objective was to evaluate and compare color Doppler ultrasound and serum thyroglobulin with radionuclide scan to define the etiology of congenital hypothyroidism. We evaluated 38 children above 3 years-old off-treatment that performed serum thyroglobulin by immunofluorometric assay, color Doppler ultrasound and radionuclide study. On color Doppler ultrasound, 11 patients had athyreosis, 5 ectopic glands, being I associated to hemiagenesis. Twenty one had topic thyroid (3 goiters, 10 normal, 8 hypoplastic). Hemiagenesis and cystic lesion were not revealed by radionuclide scan. We observed substantial agreement between color Doppler ultrasound and radionuclide scan (kappa=0.745, p<0.0001). Serum thyroglobulin in athyreosis ranged from <1.0 to 18.7 mu g/L. Patients with ectopic glands showed wider thyroglobulin range (4.5 to 123 mu g/L, median 28.4 mu g/L). Only one patient showed thyroglobulin deficiency. By using color Doppler ultrasound and serum thyroglobulin levels as valuable combined tools, we established the etiology of congenital hypothyroidism limiting excessive and harmful exams in children, like radionuclide scan.
Resumo:
Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n = 50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17 +/- 13.46 cm/s and 0.38 +/- 0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15 +/- 0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17 +/- 9.40 cm/s and 0.54 +/- 0.07. The RA had a mean ESA of 1.12 +/- 1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828 +/- 0.296. The IA showed PSV and RI values of 32.16 +/- 9.33 cm/s and 0.52 +/- 0.06, respectively. The mean ESA of all IAs was 0.73 +/- 0.61 m/s(2). The calculated upper limit of the reference value was 2.0 m/s(2). The mean renal-interlobar artery ratio was 1.45 +/- 0.57. The RI values obtained in this study were similar to values reported in the literature. Some conditions that lead to a decrease in compliance and to an increase in vascular resistance can affect the Doppler spectral waveforms without changes in RI. To our knowledge, there are no studies that were directed toward to the normal ESA values of the renal vasculature in Persian cats. This study introduced a new ratio between the PSV of the RA and the IA. This index was developed based on the well-known effects of Doppler on the detection of stenosis, regardless of the cause. Further studies are necessary to verify the hemodynamic behavior of this index under pathological conditions in cats as well as the effect of aging, nephropathies and systemic pressure on Doppler velocimetric parameters. (C) 2010 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives: The aim of this study was to determine the correlation between ductus venosus (DV) Doppler velocimetry and fetal cardiac troponin T (cTnT). Study design: Between March 2007 and March 2008, 89 high-risk pregnancies were prospectively studied. All patients delivered by cesarean section and the Doppler exams were performed on the same day. Multiple regression included the following variables: maternial age, parity, hypertension, diabetes, gestational age at delivery, umbilical artery (UA) S/D ratio, diagnosis of absent or reversed end-diastolic flow velocity (AREDV) in the UA, middle cerebral artery (MCA) pulsatility index (131), and DV pulsatility index for veins (PIV). Immediately after delivery, UA blood samples were obtained for the measurement of pH and cTnT levels. Statistical analysis included the Kruskal-Wallis test and multiple regressions. Results: The results showed a cTnT concentration at birth >0.05 ng/ml in nine (81.8%) of AREDV cases, a proportion significantly higher than that observed in normal UA S/D ratio and UA S/D ratio >p95 with positive diastolic blood flow (7.7 and 23.1%, respectively, p < 0.001). A positive correlation Was found between abnormal DV-PIV and elevated cTnT levels in the UA. Multiple regression identified DV-PIV and a diagnosis of AREDV as independent factors associated with abnormal fetal cTnT levels (p < 0.0001, F(2.86) = 63.5, R = 0.7722). Conclusion: DV-PIV was significantly correlated with fetal cTnT concentrations at delivery. AREDV and abnormal DV flow represent severe cardiac compromise, with increased systemic venous pressure, and a rise in right ventricular afterload, demonstrated by myocardial damage and elevated fetal cTnT. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
We evaluated 16 pregnant women with gestational age between 20 and 32 weeks in acute severe hypertension which were randomly allocated to receive either hydralazine or labetalol. Blood pressure and Doppler ultrasound parameters from maternal uterine and fetal middle cerebral and umbilical arteries were assessed during acute severe hypertension and after treatment. A significant reduction in systolic and diastolic blood pressure was observed in both groups. A significant change in Doppler parameters was observed only in pregnant women who received hydralazine: an increase in uterine arteries resistance index. We concluded that both drugs were highly effective in reducing blood pressure in these women. Despite the observed increase in resistance index of uterine arteries associated with hydralazine, the use of hydralazine and labetalol were not related to any significant changes in fetal Doppler, which is reassuring about the safety of these drugs when treating acute severe hypertension in pregnancy. (E-mail: wpmartins@gmail.com) (C) 2011 World Federation for Ultrasound in Medicine & Biology.
Resumo:
The aim of this study was to establish normal ranges of blood flow velocities and indices in the fetal ductus venosus (DV) during the second half of normal pregnancy. A Doppler study of 60 healthy pregnant women without fetal pathologies was performed during the second half of pregnancy. The peak systolic velocity (PSV), peak diastolic velocity (PDV), maximum velocity during atrial contraction (VAC), peak systolic velocity/maximum velocity during atrial contraction (S/A ratio), pulsatility index for the vein (PIV), preload index (PLI) and velocity index for the vein (VIV) were calculated from the DV at 4-week intervals. A significant increase in PSV, PDV and VAC was observed from the 20-23(6/7) to the 28-31(6/7) weeks, with stabilization of values until the end of the pregnancy. On the other hand, the study showed a significant decrease for the S/A ratio, PIV, PLI and VIV from the 20-23(6/7) to the 28-31(6/7) weeks and remaining stable from then until term. (E-mail:dralemar@uol.com.br) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Background/Purpose. Posttransplantation portal vein thrombosis (PVT) can have severe health consequences, and portal hypertension and other consequences of the long-term privation of portal inflow to the graft may be hazardous, especially in young children. The Rex shunt has been used successfully to treat PVT patients since 1998. In 2007, we started to perform this surgery in patients with idiopathic PVT and late posttransplantation PVT. Herein we have reported our experience with this technique in acute posttransplantation PVT. Methods. Three patients of ages 12, 15, and 18 months underwent cadaveric (n = 1) or living donor (n = 2) orthotopic liver transplantation (OLT). All patients had biliary atresia with portal vein hypoplasia; they developed acute PVT on the first postoperative day. They underwent a mesenteric-portal surgical shunt (Rex shunt) using a left internal jugular vein autograft (n = 2) or cadaveric iliac vein graft (n = 1) on the first postoperative day. Results. The 8-month follow-up has confirmed shunt patency by postoperative Doppler ultrasound. There have been no biliary complications to date. Conclusions. The mesenteric-portal shunt (Rex shunt) using an autograft of the left internal jugular or a cadaveric vein graft should be considered for children with acute PVT after OLT. These children usually have small portal veins; reanastomosis is often unsuccessful. In addition, this technique has the advantage to avoid manipulation of the hepatic hilum and biliary anastomosis. Although this study was based on a limited experience, we concluded that this technique is feasible, with great benefits to and low risks for these patients.
Resumo:
Background and Purpose. Late portal vein thrombosis (PVT) can be extremely well tolerated, although portal hypertension and other consequences of the long-term deprivation of portal inflow to the graft may be hazardous, especially in young children. Recently, the ""Rex shunt"" has been used successfully to treat these patients. We now report the initial experience with this novel technique. Methods. A 3-year-old girl with PVT at 7 months after whole organ cadaveric liver transplant displayed portal hypertension with an episode of gastrointestinal bleeding, requiring a mesenteric-portal surgical shunt (""Rex shunt"") using a left internal jugular vein autograft. Results. Upon current follow-up of 6 months, postoperative Doppler ultrasound confirmed shunt patency. Endoscopic status was significantly improved after surgery with resolution of portal hypertension. There was no recurrence of bleeding. Conclusions. The mesenteric-portal shunt (""Rex shunt""), using a left internal jugular vein autograft, should be considered for children with late PVT after liver transplantation. Although this is an initial experience, we may conclude that this technique is feasible, with great potential benefits and low risks for these patients.
Resumo:
Objectives. To examine the effects of betamethasone administration on umbilical artery (UA), middle cerebral artery (MCA) and ductus venosus (DV) Doppler flow. Design. Longitudinal prospective study. Setting: Fetal Surveillance Unit, Department of Obstetrics and Gynecology, University of Sao Paulo, Sao Paulo, Brazil. Population. Thirty-two singleton pregnancies complicated by fetal growth restriction with absent end-diastolic flow in the UA. Methods. Pulsatility index (PI) of the UA, MCA and DV was measured from 26 to 34 weeks prior to and within 24 or 48 hours after starting betamethasone treatment course. Analysis of variance for repeated measures was used to determine the changes in the fetal hemodynamic Doppler flow following maternal corticosteroid administration. Main outcome measures. Improvement of UA-PI within 24 hours and DV-PIV (venous pulsatility) within 48 hours from the first betamethasone dose. Results. Mean gestational age at delivery was 29.3 (1.8) weeks and birthweight was 806.6 (228.2) g. A reduction in the UA-PI was observed in 29 (90.6%) cases, with return of end-diastolic flow in 22 (68.7%). The mean UA-PI were 2.84 (0.52) before corticosteroid administration, 2.07 (0.56) within 24 hours and 2.42 (0.75) after 48 hours, with a significant difference along the evaluations (p0.001). No significant changes in the MCA Doppler were observed. DV-PIV decreased from 1.06 (0.23) prior corticosteroids administration to 0.73 (0.16) within 24 hours and 0.70 (0.19) after 48 hours (p0.001). Conclusions. There was reduction in the umbilical artery and in the DV pulsatility indices within 24 hours from betamethasone administration that was maintained up to 48 hours.
Resumo:
The aim of the study was to verify whether post-menopausal hormone replacement therapy (HRT) modifies autoantibody titers against oxidized low-density lipoprotein (LDL) (anti-LDLoxi), against epitopes of oxidized apolipoprotein B100 and common carotid intima-media thickness (IMT) in these women. Sixty-eight women in pre-menopause (PMW) and 216 in post-menopause (POMW) were recruited; eighty-three had undergone HRT for at least 12 months, where 48 received conjugated estrogens alone (EHRT) and 35 received conjugated estrogen and medroxyprogesterone acetate (CHRT). ELISA was used to determine autoantibodies. Lipoprotein lipase (LPL), hepatic lipase (HL), cholesterol ester transfer protein (CETP) and phospholipid transfer protein (PLTP) activities were assayed by radiometric methods. IMT was measured using Doppler ultrasound. Anti-oxidized LDL and anti-D antibodies increased by 40% (p <= 0.003) and 42% (p <= 0.006), respectively, with menopause. There was a surprising and significant 7% reduction in anti-D2 antibody titers with HRT (p <= 0.050), indicating a positive effect of treatment on the immune response to oxidized LDL. Combined HRT decreased activities of HL and LPL. HRT did not change common carotid IMT, which was increased by 32% as expected after menopause (p <= 0.030). This study describes, for the first time, the protective effect of HRT on decreasing autoantibody titers against oxidized apolipoprotein B in LDL.
Resumo:
Objective To determine accuracy of first trimester detection of single umbilical artery (SUA). Methods The number of vessels in the umbilical cord was examined in a prospective cohort of 779 singleton, low-risk, unselected pregnancies, in the first (11-13 weeks) and second (17-24 weeks) trimesters, using both power and color Doppler and after delivery, by placental histopathologic exam. Concordance between first and second trimester findings to postnatal diagnoses was compared by calculating kappa coefficients. Results There was medium concordance between the findings in the first trimester and the postnatal diagnoses (kappa = 0.52) and high concordance (kappa = 0.89) for the second trimester scan. Sensitivity, specificity, positive and negative predictive values for the findings in the first trimester were 57.1, 98.9, 50.0 and 99.2% and for the second trimester were 86.6, 99.9, 92.9 and 99.7%. Conclusion Sensitivity and positive predictive value of first trimester scan to identify an isolated SUA in a prospective unselected population was poor. Diagnosis of isolated SUA as well as a definitive judgment about the presence of associated anomalies would still require a scan in the second trimester. Copyright (C) 2011 John Wiley & Sons, Ltd.