108 resultados para PLANTAR PRESSURES
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Background: Diabetic neuropathy leads to progressive loss of sensation, lower-limb distal muscle atrophy, autonomic impairment, and gait alterations that overload feet. This overload has been associated with plantar ulcers even with consistent daily use of shoes. We sought to investigate and compare the influence of diabetic neuropathy and plantar ulcers in the clinical history of diabetic neuropathic patients on plantar sensitivity, symptoms, and plantar pressure distribution during gait while patients wore their everyday shoes. Methods: Patients were categorized into three groups: a control group (CG; n = 15), diabetic patients with a history of neuropathic ulceration (DUG; n = 8), and diabetic patients without a history of ulceration (DG; n = 10). Plantar pressure variables were measured by Pedar System shoe insoles in five plantar regions during gait while patients wore their own shoes. Results: No statistical difference between neuropathic patients with and without a history of plantar ulcers was found in relation to symptoms, tactile sensitivity, and duration of diabetes. Diabetic patients without ulceration presented the lowest pressure-time integral under the heel (72.1 +/- 16.1 kPa x sec; P=.0456). Diabetic patients with a history of ulceration presented a higher pressure-time integral at the midfoot compared to patients in the control group (59.6 +/- 23.6 kPa x sec x 45.8 +/- 10.4 kPa x sec; P = .099), and at the lateral forefoot compared to diabetic patients without ulceration (70.9 +/- 17.7 kPa sec x 113.2 +/- 61.1 kPa x sec, P = .0193). Diabetic patients with ulceration also presented the lowest weight load under the hallux (0.06 +/- 0.02%, P = .0042). Conclusions: Although presenting a larger midfoot area, diabetic neuropathic patients presented greater pressure-time integrals and relative loads over this region. Diabetic patients with ulceration presented an altered dynamic plantar pressure pattern characterized by overload even when wearing daily shoes. Overload associated with a clinical history of plantar ulcers indicates future appearance of plantar ulcers. (J Am Podiatr Med Assoc 99(4): 285-294, 2009)
Resumo:
Background. Foot deformities have been related to diabetic neuropathy progression but their influence on plantar distribution during dynamic tasks is not completely understood. The purpose of the present study was to investigate the influence of metatarsal head prominence and claw toes on regional plantar pressures during gait in patients with diabetic neuropathy Methods Seventy-one adults participated in this study categorized into three groups: a control group (CG, n = 32), patients with diabetic neuropathy without any foot deformities (DG, n = 20), and patients with diabetic neuropathy with metatarsal head prominence and/or claw toes (DMHG, n = 19). Plantar pressure variables (contact area, peak pressure, and maximum mean pressure) were evaluated during gait on rearfoot, midfoot, and forefoot using capacitive insoles (Pedar-X System, Novel Inc., Munich, Germany). A general linear model was applied to repeatedly measure and analyze variance relationships between groups and areas. Results. DMHG. presented larger contact areas at the forefoot and midfoot along with higher peak pressure at the rearfoot compared to the other two groups The DG showed higher mean pressure at the midfoot compared to:the other two groups. Conclusion. The coexistence of diabetic neuropathy and metatarsal head prominence in addition to claw toes, resulted in overloading the rearfoot and enhancing the contact area of forefoot and midfoot while walking. This plantar pressure distribution is a result of a different coordination pattern adopted in order to reduce plantar loads at the anterior parts of the foot that were structurally altered. Patients with diabetic neuropathy without any forefoot deformities presented a different plantar pressure distribution than patients with deformities suggesting that both neuropathy and structural foot alterations can influence foot rollover mechanisms.
Resumo:
Background: The purpose of this study was to investigate the ankle range of motion during neuropathic gait and its influence on plantar pressure distribution in two phases during stance: at heel-strike and at push-off. Methods: Thirty-one adults participated in this study (control group, n = 16; diabetic neuropathic group, n = 15). Dynamic ankle range of motion (electrogoniometer) and plantar pressures (PEDAR-X system) were acquired synchronously during walking. Plantar pressures were evaluated at rearfoot. midfoot and forefoot during the two phases of stance. General linear model repeated measures analysis of variance was applied to investigate relationships between groups, areas and stance phases. Findings: Diabetic neuropathy patients walked using a smaller ankle range of motion in stance phase and smaller ankle flexion at heel-strike (P = 0.0005). Peak pressure and pressure-time integral values were higher in the diabetic group in the midfoot at push-off phase when compared to heel-strike phase. On the other hand, the control group showed similar values of peak pressure in midfoot during both stance phases. Interpretation: The ankle mobility reduction observed could be associated to altered plantar pressure distribution observed in neuropathic subjects. Results demonstrated that midfoot and forefoot play a different role in subjects with neuropathy by receiving higher loads at push-off phase that are probably due to smaller ankle flexion at stance phase. This may explain the higher loads in anterior areas of the foot observed in diabetic neuropathy subjects and confirm an inadequate foot rollover associated to the smaller ankle range of motion at the heel-strike phase. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The type of surface used for running can influence the load that the locomotor apparatus will absorb and the load distribution could be related to the incidence of chronic injuries. As there is no consensus on how the locomotor apparatus adapts to loads originating from running Surfaces with different compliance, the objective of this study was to investigate how loads are distributed over the plantar surface while running on natural grass and on a rigid surface-asphalt. Forty-four adult runners with 4 3 years of running experience were evaluated while running at 12 km/h for 40 m wearing standardised running shoes and Pedar insoles (Novel). Peak pressure, contact time and contact area were measured in six regions: lateral, central and medial rearfoot, midfoot, lateral and media] forefoot. The Surfaces and regions were compared by three ANOVAS (2 x 6). Asphalt and natural grass were statistically different in all variables. Higher peak pressures were observed on asphalt at the central (p < 0.001) [grass: 303.8(66.7) kPa; asphalt: 342.3(76.3) kPa] and lateral rearfoot (p < 0.001) [grass: 312.7(75.8) kPa: asphalt: 350.9(98.3) kPa] and lateral forefoot (p < 0.001) [grass: 221.5(42.9) kPa asphalt: 245.3(55.5) kPa]. For natural grass, contact time and contact area were significantly greater at the central rearfoot (p < 0.001). These results suggest that natural grass may be a Surface that provokes lighter loads on the rearfoot and forefoot in recreational runners. (C) 2008 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives: To investigate plantar pressure distribution in individuals with and without Patellofemoral Pain Syndrome during the Support phase of stair descent. Design: Observational case-control study. Participants: 30 Young adults With Patellofemoral Pain Syndrome and 44 matched controls. Main outcome measures: Contact area, peak pressure and pressure-time integral (Novel Pedar-X system) were evaluated in six plantar areas (medial, central and lateral rearfoot: midfoot; medial and lateral forefoot) during stair descent. Results: Contact area was greater in the Patellofemoral Pain Syndrome Group at medial rearfoot (p = 0.019) and midfoot (p < 0.001). Subjects with Patellofemoral pain Syndrome presented smaller peak pressures (p < 0.001). Conclusion: The pattern of plantar pressure distribution during stair descent in Patellofemoral Pain Syndrome Subjects was different from controls. This seems to be related to greater medial rearfoot and midfoot Support. Smaller plantar loads found in Patellofemoral Pain Syndrome subjects during stair descent reveal a more Cautious motor pattern in a challenging task. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Background: Plantar fasciitis is the third most frequent injury in runners. Despite its high prevalence, its pathogenesis remains inconclusive. The literature reports overload as the basic mechanism for its development. However, the way that these plantar loads are distributed on the foot surface of runners with plantar fasciitis and the effects of pain on this mechanical factor has not yet been investigated. Therefore, the aim of this study was to evaluate and compare the plantar pressure distributions during running in runners with symptom or history of plantar fasciitis and runners without the disease. Methods: Forty-five recreational runners with plantar fasciitis (30 symptomatic and 15 with previous history of the disease) and 60 runners without plantar fasciitis (control group) were evaluated. Pain was assessed by a visual analogue scale. All runners were evaluated by means of the Pedar system insoles during running forty meters at a speed of 12(5%) km/h, using standard sport footwear. Two-way ANOVAS were employed to investigate the main and interaction effects between groups and plantar areas. Findings: No interaction effects were found for any of the investigated variables: peak pressure (P=0.61), contact area (P=0.38), contact time (P=0.91), and the pressure-time integral (P=0.50). Interpretation: These findings indicated that the patterns of plantar pressure distribution were not affected in recreational runners with plantar fasciitis when compared to control runners. Pain also did not interfere with the dynamic patterns of the plantar pressure distributions. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Objectives: The objective of the present study was to evaluate intraluminal esophageal pressure during voice and speech emission in speaking laryngectomees with a tracheoesophageal prosthesis. Methods: In our prospective analysis in a tertiary-care academic hospital, 25 laryngectomees were divided into 2 groups: 11 speaking individuals with a tracheoesophageal prosthesis and a control group of 14 nonspeaking laryngectomees. All patients were subjected to manometry during voice and speech emission tests. We determined the pressures achieved in the distal, middle, and proximal parts of the esophagus. Results: Statistical analysis revealed that the amplitude of pressure in the distal esophagus during sound emission was higher in speaking laryngectomees; in the middle esophagus, intraluminal pressure during emission of the sentence was higher in speaking subjects, and in the proximal esophagus there was no difference between the groups. Conclusions: During the manometric evaluation of the distal and middle esophagus in the presence of voice and speech emission, the intraluminal pressure revealed a significant difference for the speaking laryngectomees with a tracheoesophageal prosthesis. The proximal esophagus behaved similarly in the groups of speakers and nonspeakers. Speaking laryngectomees with a tracheoesophageal prosthesis depend on a differentiated performance of the middle and distal parts of the esophagus.
Resumo:
In tetrapod squamates, the diversity of micro-ornamentations of the epidermis of the contact areas of hands and feet is generally associated with constraints and modalities related to locomotion. Polychrus acutirostris is a medium-sized lizard that occurs in open heterogeneous habitats in South America, such as the cerrados, caatingas, and fallow lands. It progresses slowly on branches of various diameters in its arboreal environment. It can also move more rapidly on the ground. The hands and feet are prehensile and may be considered an adaptation for grasping and climbing. Epidermal surfaces from the palmar and plantar areas of the hands and feet of P. acutirostris were prepared for SEM examination, and studied at various magnifications. They show three major levels of complexity: (1) scale types, organized in gradients of size and imbrication, (2) scalar ornamentations, organized by increasing complexity and polarity, and (3) presence of Oberhautchen showing typically iguanian honeycomb micro-ornamentations. The shape and surface structure of the scales with their pattern of micro-ornamental peaks, which improve grip, and the grasping hands and feet indicate that P. acutirostris is morpho-functionally specialized for arboreality. (C) 2009 Elsevier GmbH. All rights reserved.
Resumo:
We consider incompressible Stokes flow with an internal interface at which the pressure is discontinuous, as happens for example in problems involving surface tension. We assume that the mesh does not follow the interface, which makes classical interpolation spaces to yield suboptimal convergence rates (typically, the interpolation error in the L(2)(Omega)-norm is of order h(1/2)). We propose a modification of the P(1)-conforming space that accommodates discontinuities at the interface without introducing additional degrees of freedom or modifying the sparsity pattern of the linear system. The unknowns are the pressure values at the vertices of the mesh and the basis functions are computed locally at each element, so that the implementation of the proposed space into existing codes is straightforward. With this modification, numerical tests show that the interpolation order improves to O(h(3/2)). The new pressure space is implemented for the stable P(1)(+)/P(1) mini-element discretization, and for the stabilized equal-order P(1)/P(1) discretization. Assessment is carried out for Poiseuille flow with a forcing surface and for a static bubble. In all cases the proposed pressure space leads to improved convergence orders and to more accurate results than the standard P(1) space. In addition, two Navier-Stokes simulations with moving interfaces (Rayleigh-Taylor instability and merging bubbles) are reported to show that the proposed space is robust enough to carry out realistic simulations. (c) 2009 Elsevier B.V. All rights reserved.
Resumo:
Lead calcium titanate (Pb(1-x)Ca(x)TiO(3) or PCT) thin films have been thermally treated under different oxygen pressures, 10, 40 and 80 bar, by using the so-called chemical solution deposition method. The structural, morphological, dielectric and ferroelectric properties were characterized by x-ray diffraction, FT-infrared and Raman spectroscopy, atomic force microscopy and polarization-electric-field hysteresis loop measurements. By annealing at a controlled pressure of around 10 and 40 bar, well-crystallized PCT thin films were successfully prepared. For the sample submitted to 80 bar, the x-ray diffraction, Fourier transformed-infrared and Raman data indicated deviation from the tetragonal symmetry. The most interesting feature in the Raman spectra is the occurrence of intense vibrational modes at frequencies of around 747 and 820 cm(-1), whose presence depends strongly on the amount of the pyrochlore phase. In addition, the Raman spectrum indicates the presence of symmetry-breaking disorder, which would be expected for an amorphous (disorder) and mixed pyrochlore-perovskite phase. During the high-pressure annealing process, the crystallinity and the grain size of the annealed film decreased. This process effectively suppressed both the dielectric and ferroelectric behaviour. Ferroelectric hysteresis loop measurements performed on these PCT films exhibited a clear decrease in the remanent polarization with increasing oxygen pressure.
Resumo:
Magnetic M( T, H, P) and electrical transport.( T, H, P) measurements in a strong spin-lattice-charge coupled La(0.7)Ca(0.3)MnO(3) system have been conducted. The application of H and P leads to the formation of different magnetic domain structures in the vicinity and below the polaronic-to-ferromagnetic transition temperature. The charge mobility is more sensitive to the variation of the spatial wave function overlap between Mn(3+) eg and O(2-) 2p orbitals due to the applied compacting pressure rather than the relative spin orientation between neighbouring Mn ions when the magnetic field is applied. In spite of the presence of different magnetic domain structures due to the sample history, the effect of magnetic field and pressure is less pronounced at lower temperatures on electrical transport properties.
Resumo:
We design and investigate a sequential discontinuous Galerkin method to approximate two-phase immiscible incompressible flows in heterogeneous porous media with discontinuous capillary pressures. The nonlinear interface conditions are enforced weakly through an adequate design of the penalties on interelement jumps of the pressure and the saturation. An accurate reconstruction of the total velocity is considered in the Raviart-Thomas(-Nedelec) finite element spaces, together with diffusivity-dependent weighted averages to cope with degeneracies in the saturation equation and with media heterogeneities. The proposed method is assessed on one-dimensional test cases exhibiting rough solutions, degeneracies, and capillary barriers. Stable and accurate solutions are obtained without limiters. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A cetamina tem demonstrado efeito analgésico em doses subanestésicas, além da manutenção da estabilidade dos parâmetros fisiológicos. O estudo objetivou avaliar os efeitos cardiorrespiratórios e a analgesia pós-operatória da cetamina administrada por via epidural, por infusão intravenosa contínua ou pela associação de ambas, em cães submetidos à osteossíntese de fêmur. Foram utilizadas 25 cadelas, hígidas, distribuídas aleatoriamente em quatro grupos: CEP (2mg kg-1 de cetamina associada à lidocaína 2% via epidural), CIV (lidocaína 2% via epidural e 1mg kg-1 de cetamina IV seguido de infusão contínua IV com 100µg kg min-1 da mesma), CIVEP (2mg kg-1 de cetamina associada à lidocaína 2% via epidural e 1mg kg-1 de cetamina IV, seguido de infusão contínua IV com 100µg kg min-1) e CON (anestesia epidural com lidocaína 2%). Avaliaram-se FC, f, PAS, PAM, PAD, T°C, tempo de bloqueio motor e analgesia pós-operatória por meio de escala analógica visual. Houve elevação da FC no CIV e diminuição desse parâmetro no CEP. As pressões arteriais mantiveram-se dentro dos valores fisiológicos e não foram observadas diferenças na f e T°C. O tempo de duração do bloqueio anestésico foi potencializado nos grupos que receberam cetamina epidural, diferindo significativamente em relação ao controle. O tempo para a analgesia resgate não diferiu entre os grupos. Conclui-se que a administração de cetamina pela via epidural, por infusão contínua intravenosa ou pela associação de ambas promoveu estabilidade cardiorrespiratória no período transcirúrgico, porém não foi capaz de prolongar a duração da analgesia pós-operatória em cães submetidos à osteossíntese de fêmur.
Resumo:
The objective was to determine the cardiopulmonary effects and eyeball centralization time obtained with 15 or 30µg kg-1 of atracurium in anesthetized dogs under spontaneous breathing. Eighteen healthy adult mixed-breed dogs were used, which received 0.1mg kg-1 acepromazine and 0.5mg kg-1 morphine IM, followed by 4mg kg-1 propofol IV and maintained on isoflurane anesthesia with spontaneous breathing. Animals received 1mL 0.9% NaCl IV (CG), 15µg kg-1 (G15) or 30µg kg-1 (G30) of atracurium IV. Eyeball centralization time was measured; heart rate (HR), systolic (SAP), mean (MAP) and diastolic (DAP) arterial pressures, respiratory rate (RR), tidal volume (Vt) and minute volume (Vm) were determined every 5min, and pH, arterial CO2 pressure (PaCO2 ), arterial O2 pressure (PaO2 ), hemoglobin oxygen saturation (SaO2 ), bicarbonate (HCO3-) and base excess (BE) every 15min until 60min. Both doses of atracurium produced a similar period of eyeball centralization. Vt in groups treated with atracurium was lower than in CG up to 15min. Vm in G15 differed from CG up to 10min and in G30 up to 25min. No differences were observed for cardiovascular parameters, RR, SaO2, PaO2, HCO3- and BE. pH decreased in CG between 30 and 60min and in G15 and G30 at 15min. G30 differed from CG between 15 and 30min. PaCO2 in GC differed from baseline between 30 and 60min and in G15 differed at 15min. Atracurium at the dose of 15µg kg-1 is adequate for short corneal procedures in inhalant-anesthetized dogs under spontaneous breathing.