115 resultados para Orthodontic brackets

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º) presented statistically significant difference from the proposed values (-7º). For the mandibular canines, American Orthodontics (-6.34º) and Ortho Organizers (-6.25º) presented statistically significant differences from the standards (-6º). Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study aimed at comparing amounts of nickel (Ni) and chromium (Cr) released from brackets from different manufacturers in simulated oral environments. 280 brackets were equally divided into 7 groups according to manufacturer. 6 groups of brackets were stainless steel, and 1 group of brackets was made of a cobalt-chromium alloy with low Ni content (0.5%). International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 ml of synthetic saliva (SS) or artificial plaque fluid (PF) over a period of 28 days at 37ºC. Solutions were replaced every 7 days, and were analyzed by spectrometry. The Kruskal-Wallis test was applied. Amounts of Ni release in SS (µg L-1 per week) varied between groups from "bellow detection limits" to 694, and from 49 to 5,948.5 in PF. The group of brackets made of cobalt-chromium alloy, with the least nickel content, did not release the least amounts of Ni. Amounts of Cr detected in SS and in PF (µg L-1 per week) were from 1 to 10.4 and from 50.5 to 8,225, respectively. It was therefore concluded that brackets from different manufacturers present different corrosion behavior. Further studies are necessary to determine clinical implications of the findings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Atualmente, os braquetes autoligáveis têm sido associados a tratamentos mais rápidos e eficazes, o que desperta a curiosidade em compará-los ao sistema convencional. Ao contrário dos braquetes tradicionais, os autoligáveis não necessitam de ligaduras, sejam elásticas ou metálicas. A literatura é farta em concluir que essa característica diminui, ostensivamente, a resistência do atrito durante as mecânicas de deslize. Além disso, existem alegações sobre a dimimuição da necessidade de extrações e de expansão maxilar com o uso desses acessórios. Portanto, o objetivo dessa revisão de literatura foi buscar os mais novos estudos a respeito dos aparelhos autoligáveis atualmente utilizados nos tratamentos ortodônticos, confirmando ou retificando as especulações vigentes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate in vitro the Knoop microhardness (Knoop hardness number [KHN]) and the degree of conversion using FT-Raman spectroscopy of a light-cured microhybrid resin composite (Z350-3M-ESPE) Vita shade A3 photopolymerized with a halogen lamp or an argon ion laser. Background Data: Optimal polymerization of resin-based dental materials is important for longevity of restorations in dentistry. Materials and Methods: Thirty specimens were prepared and inserted into a disc-shaped polytetrafluoroethylene mold that was 2.0 mm thick and 3 mm in diameter. The specimens were divided into three groups (n = 10 each). Group 1 (G1) was light-cured for 20 sec with an Optilux 501 halogen light with an intensity of 1000 mW/cm(2). Group 2 (G2) was photopolymerized with an argon laser with a power of 150 mW for 10 sec, and group 3 (G3) was photopolymerized with an argon laser at 200 mW of power for 10 sec. All specimens were stored in distilled water for 24 h at 37 degrees C and kept in lightproof containers. For the KHN test five indentations were made and a depth of 100 mu m was maintained in each specimen. One hundred and fifty readings were obtained using a 25-g load for 45 sec. The degree of conversion values were measured by Raman spectroscopy. KHN and degree of conversion values were obtained on opposite sides of the irradiated surface. KHN and degree of conversion data were analyzed by one-way ANOVA and Tukey tests with statistical significance set at p < 0.05. Results: The results of KHN testing were G1 = 37.428 +/- 4.765; G2 = 23.588 +/- 6.269; and G3 = 21.652 +/- 4.393. The calculated degrees of conversion (DC%) were G1 = 48.57 +/- 2.11; G2 = 43.71 +/- 3.93; and G3 = 44.19 +/- 2.71. Conclusions: Polymerization with the halogen lamp ( G1) attained higher microhardness values than polymerization with the argon laser at power levels of 150 and 200 mW; there was no difference in hardness between the two argon laser groups. The results showed no statistically significant different degrees of conversion for the polymerization of composite samples with the two light sources tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Using checkerboard DNA-DNA hybridisation (CDDH) assay, this randomised clinical study evaluated the contamination of metallic brackets by four cariogenic bacterial strains (Streptococcus mutans, Streptococcus sobrinus, Lactobacillus casei and Lactobacillus acidophilus) and the efficacy of 0.12% chlorhexidine gluconate (CHX) mouthwashes in reducing bacterial contamination. Methods: Thirty-nine 11-33-year-old patients under treatment with fixed orthodontic appliances were enrolled in the study and had 2 new metallic brackets bonded to premolars. Nineteen patients used a 0.12% CHX mouthwash (Periogard (R)) and 20 patients used a placebo mouthwash (control) twice a week. After 30 days, the brackets were removed and samples were obtained for analysis by CDDH. Data were analysed statistically by the Kruskal-Wallis test (alpha = 0.05) using the SAS software. Results: S. mutans, S. sobrinus, L. casei and L. acidophilus were detected in 100% of the samples from both groups. However, brackets of the control group were more heavily contaminated by S. mutans and S. sobrinus (P < 0.01). In the experimental group, although all counts decreased after rinsing with the chlorhexidine solution, there was significant difference only for S. mutans (P = 0.03). Conclusions: The use of 0.12% chlorhexidine gluconate mouthwashes can be useful in clinical practice to reduce the levels of cariogenic microorganisms in patients under treatment with fixed orthodontic appliances. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Class III skeletal malocclusion may present several etiologies, among which maxillary deficiency is the most frequent. Bone discrepancy may have an unfavorable impact on esthetics, which is frequently aggravated by the presence of accentuated facial asymmetries. This type of malocclusion is usually treated with association of Orthodontics and orthognathic surgery for correction of occlusion and facial esthetics. This report presents the treatment of a patient aged 15 years and 1 month with Class III skeletal malocclusion, having narrow maxilla, posterior open bite on the left side, anterior crossbite and unilateral posterior crossbite, accentuated negative dentoalveolar discrepancy in the maxillary arch, and maxillary and mandibular midline shift. Clinical examination also revealed maxillary hypoplasia, increased lower one third of the face, concave bone and facial profiles and facial asymmetry with mandibular deviation to the left side. The treatment was performed in three phases: presurgical orthodontic preparation, orthognathic surgery and orthodontic finishing. In reviewing the patient's final records, the major goals set at the beginning of treatment were successfully achieved, providing the patient with adequate masticatory function and pleasant facial esthetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the changes in the position and form of the temporomandibular joint articular disc in adolescents with Class II division 1 malocclusion and mandibular retrognathism treated with the Herbst appliance (phase I) and fixed orthodontic appliance (phase II). Materials and Methods: Thirty-two consecutive adolescents went through phase I of treatment and 23 completed phase II. The temporomandibular joints were evaluated qualitatively by means of magnetic resonance images at the beginning of treatment (T1), during phase I (T2), at the end of phase I (T3), and at the end of phase II (T4). Results: Significant changes in disc position were not observed with the mouth closed between T1 X T3 (P = .317), T3 X T4 (P = .287), or T1 X T4 (P = .261). At T2, on average, the disc was positioned regressively. With the mouth open, no difference was observed between T1 X T3 (P = .223) or T1 X T4 (P = .082). We did observe a significant difference between T3 X T4 (P < .05). Significant changes in the disc form were found with the mouth closed between T1 X T2 (P < .001) and T2 X T3 (P < .001). Conclusions: At the end of the two-phase treatment, in general terms, the position and form of the initial articular discs were maintained; however, in some temporomandibular joints some seemingly adverse effects were observed at T4. (Angle Orthod. 2010;80:843-852.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To describe the microscopic pulpal reactions resulting from orthodontically induced tooth movement associated with low-level laser therapy (LLLT) in rats. Materials and Methods: Forty-five young male Wistar rats were randomly assigned to three groups. In group I (n = 20), the maxillary right first molars were submitted to orthodontic movement with placement of a coil spring. In group II (n = 20), the teeth were submitted to orthodontic movement plus LLLT at 4 seconds per point (buccal, palatal, and mesial) with a GaAlAs diode laser source (830 nm, 100 mW, 18 J/cm(2)). Group III (n = 5) served as a control (no orthodontic movement or LLLT). Groups I and 11 were divided into four subgroups according to the time elapsed between the start of tooth movement and sacrifice (12 hours, 24 hours, 3 days, and 7 days). Results: Up until the 3-day period, the specimens in group I presented a thicker odontoblastic layer, no cell-free zone of Weil, pulp core with differentiated mesenchymal and defense cells, and a high concentration of blood vessels. In group II, at the 12- and 24-hour time points, the odontoblastic layer was disorganized and the cell-free zone of Weil was absent, presenting undifferentiated cells, intensive vascularization with congested capillaries, and scarce defense cells in the cell-rich zone. In groups I and II, pulpal responses to the stimuli were more intense in the area underneath the region of application of the force or force/laser. Conclusions: The orthodontic-induced tooth movement and LLLT association showed reversible hyperemia as a tissue response to the stimulus. LLLT leads to a faster repair of the pulpal tissue due to orthodontic movement. (Angle Orthod. 2010;80:116-122.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several studies have shown that austenitic stainless steels are suitable for use in the final phases of orthodontic treatments, such as finishing and retention. These steels demonstrate appropriate mechanical properties, such as high ultimate tensile strength and good corrosion resistance. A new class of materials, the austenic-ferritic stainless steels, is substituting for austenitic stainless steels in several industrial applications where these properties are necessary. This work supports the hypothesis that orthodontic wires of austenic-ferritic stainless steels can replace austenitic stainless steels. The advantages are cost reduction and decrease of the nickel hypersensitivity effect in patients undergoing orthodontic treatments. The object of this study was to evaluate wires of austenitic-ferritic stainless steel SEW 410 Nr. 14517 (Cr26Ni6Mo3Cu3) produced by cold working through rolling and drawing processes. Tests were performed to evaluate the ultimate tensile strength, hardness, ductility, and formability. In accordance with technical standards the wires exhibited ultimate tensile strength and ductility suitable for orthodontic clinical applications. These austenitie-ferritic wires can be an alternative to substitute the common commercial wires of austenic stainless steels with the advantage of decreasing the nickel content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: It has long been demonstrated that epidermal growth factor (EGF) has catabolic effects oil bone. Thus. we examined the role of EGF in regulating mechanically induced bone modeling in a rat model of orthodontic tooth movement. Main methods: The maxillary first molars of rats were moved mesially using an orthodontic appliance attached to the maxillary incisor teeth. Rats were randomly divided into 4 groups: (G1) administration of PBS (Phosphate buffer saline Solution (n = 24); (G2) administration of empty liposomes (it = 24): (Q) administration 20 rig of EGF Solution (n = 24): and (G4) 20 ng of EGF-liposomes Solution (it = 24). Each Solution was injected in the mucosa of the left first molar adjacent to the appliance. At days 5, 10, 14 and 2 1 after drug administration. 6 animals of each group were sacrificed. Histomorphometric analysis was used to quantify osteoclasts (Tartrate-resistant acid phosphatase (TRAP) + cells) and tooth movement. Using immunohistochemistry assay we evaluated the RANKL (receptor activator of nuclear factor kappa B ligand) and epidermal growth factor receptor (EGFR) expression. Key findings: The EGF-liposome administration showed an increased tooth movement and osteoclast numbers compared to controls (p<0.05). This was correlated with intense RANKL expression. Both osteoblasts and osteoclasts expressed EGFR. Significance: Local delivery of EGF-liposome stimulates, osteoclastogenesis and tooth movement. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arantes GM, Arantes VMN, Ashmawi HA, Posso IP To study the efficacy of tenoxicam for pain control, its potential for preemptive analgesia, and its influence on the orthodontic movement of upper canine teeth. This was a randomized controlled double-blind cross-over study. The patients were divided into three groups. Two groups received tenoxicam in daily doses of 20 mg orally for 3 days. Group A received the first dose of the drug before orthodontic activation and group B, just afterwards. Group C (control) received a placebo for 3 days. All groups had access to 750 mg of paracetamol up to four times a day. Three orthodontic activations were performed at 30-day intervals. Each patient belonged to two different groups. Pain intensity was assessed using a descriptive Pain Scale and a Visual Analog Scale. Private clinic; 36 patients undergoing bilateral canine tooth retraction. The statistical analysis did not show any difference in movement between the active groups and the control at any time. There was no statistical difference between the groups that received tenoxicam. Pain intensity in these groups was lower than in the placebo group. The difference in pain intensity between the active groups and the control was greatest at the assessment made 12 h after activation and it tended to zero, 72 h after activation. Tenoxicam did not influence orthodontic movement of the upper canines. It was effective for pain control and did not present any preemptive analgesic effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine if systemic stress affects the biological reactions occurring during orthodontic tooth movement. Methods: Four groups of male 10 week-old Wistar rats were used. Group A animals (N=10) were restrained for one hour per day for 40 days; Group B animals (N=10) were restrained for one hour per day for three days; Group C (N=10) and Group D (N=8) animals were unrestrained. The upper left first molars in the rats in Groups A (long-term stress), B (short-term stress) and C (control) were moved mesially during the last 14 days of the experiment. The animals in Group D (N=8) were used for body weight and hormonal dosage comparisons only. They were not subjected to any stress and did not have appliances fitted. All animals were killed at 18 weeks of age and blood collected for measurement of plasma corticosterone. Tooth movement was measured with an electronic caliper. The right and left hemi-maxillae of five rats from each group were removed and the number of tartrate-resistant acid phosphatase (TRAP) positive cells, defined as osteoclasts, adjacent to the mesial roots of the upper first molars counted. The contralateral side in each animal served as the control (split-mouth design). Results: Corticosterone levels were significantly higher in the stressed groups (Groups A and B) than in the control group (Group C). Tooth movement was significantly greater in Group A (long-term stress) compared with Group B (short-term stress) and Group C (control), which did not differ from each other. There were significantly more osteoclasts in the long-term stress group than in the short-term stress and control groups. Conclusion: Persistent systemic stress increases bone resorption during orthodontic tooth movement. Systemic stress may affect the rate of tooth movement during orthodontic treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orthodontic tooth movement is achieved by the remodeling of alveolar bone in response to mechanical loading, and is supposed to be mediated by several host mediators, such as chemokines. In this study we investigated the pattern of mRNAs expression encoding for osteoblast and osteoclast related chemokines, and further correlated them with the profile of bone remodeling markers in palatal and buccal sides of tooth under orthodontic force, where tensile (T) and compressive (C) forces, respectively, predominate. Real-time PCR was performed with periodontal ligament mRNA from samples of T and C sides of human teeth submitted to rapid maxillary expansion, while periodontal ligament of normal teeth were used as controls. Results showed that both T and C sides exhibited significant higher expression of all targets when compared to controls. Comparing C and T sides, C side exhibited higher expression of MCP-1/CCL2, MIP-1 alpha/CCL3 and RANKL, while T side presented higher expression of OCN. The expression of RANTES/CCL5 and SDF-1/CXCL12 was similar in C and T sides. Our data demonstrate a differential expression of chemokines in compressed and stretched PDL during orthodontic tooth movement, suggesting that chemokines pattern may contribute to the differential bone remodeling in response to orthodontic force through the establishment of distinct microenvironments in compression and tension sides. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865