288 resultados para Objective diagnosis

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multispectral widefield optical imaging has the potential to improve early detection of oral cancer. The appropriate selection of illumination and collection conditions is required to maximize diagnostic ability. The goals of this study were to (i) evaluate image contrast between oral cancer/precancer and non-neoplastic mucosa for a variety of imaging modalities and illumination/collection conditions, and (ii) use classification algorithms to evaluate and compare the diagnostic utility of these modalities to discriminate cancers and precancers from normal tissue. Narrowband reflectance, autofluorescence, and polarized reflectance images were obtained from 61 patients and 11 normal volunteers. Image contrast was compared to identify modalities and conditions yielding greatest contrast. Image features were extracted and used to train and evaluate classification algorithms to discriminate tissue as non-neoplastic, dysplastic, or cancer; results were compared to histologic diagnosis. Autofluorescence imaging at 405-nm excitation provided the greatest image contrast, and the ratio of red-to-green fluorescence intensity computed from these images provided the best classification of dysplasia/cancer versus non-neoplastic tissue. A sensitivity of 100% and a specificity of 85% were achieved in the validation set. Multispectral widefield images can accurately distinguish neoplastic and non-neoplastic tissue; however, the ability to separate precancerous lesions from cancers with this technique was limited. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3516593]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: We carry out a systematic assessment on a suite of kernel-based learning machines while coping with the task of epilepsy diagnosis through automatic electroencephalogram (EEG) signal classification. Methods and materials: The kernel machines investigated include the standard support vector machine (SVM), the least squares SVM, the Lagrangian SVM, the smooth SVM, the proximal SVM, and the relevance vector machine. An extensive series of experiments was conducted on publicly available data, whose clinical EEG recordings were obtained from five normal subjects and five epileptic patients. The performance levels delivered by the different kernel machines are contrasted in terms of the criteria of predictive accuracy, sensitivity to the kernel function/parameter value, and sensitivity to the type of features extracted from the signal. For this purpose, 26 values for the kernel parameter (radius) of two well-known kernel functions (namely. Gaussian and exponential radial basis functions) were considered as well as 21 types of features extracted from the EEG signal, including statistical values derived from the discrete wavelet transform, Lyapunov exponents, and combinations thereof. Results: We first quantitatively assess the impact of the choice of the wavelet basis on the quality of the features extracted. Four wavelet basis functions were considered in this study. Then, we provide the average accuracy (i.e., cross-validation error) values delivered by 252 kernel machine configurations; in particular, 40%/35% of the best-calibrated models of the standard and least squares SVMs reached 100% accuracy rate for the two kernel functions considered. Moreover, we show the sensitivity profiles exhibited by a large sample of the configurations whereby one can visually inspect their levels of sensitiveness to the type of feature and to the kernel function/parameter value. Conclusions: Overall, the results evidence that all kernel machines are competitive in terms of accuracy, with the standard and least squares SVMs prevailing more consistently. Moreover, the choice of the kernel function and parameter value as well as the choice of the feature extractor are critical decisions to be taken, albeit the choice of the wavelet family seems not to be so relevant. Also, the statistical values calculated over the Lyapunov exponents were good sources of signal representation, but not as informative as their wavelet counterparts. Finally, a typical sensitivity profile has emerged among all types of machines, involving some regions of stability separated by zones of sharp variation, with some kernel parameter values clearly associated with better accuracy rates (zones of optimality). (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although the utility of the acetylcholinesterase (AChE) histochemistry on rectal suction biopsy in diagnosing Hirschsprung`s disease (HD) has been documented, few reports address a great number of biopsies and patients. Our aim is to present a 17-year experience on the method of rectal suction biopsy and AChE histochemical staining for diagnosis of intestinal dysganglionoses. Between August 1989 and July 2006, 297 children suspected of having HD were submitted to rectal suction biopsies that were evaluated by the same two surgeons. There were 18 complications (6.0%), namely one self-limited rectal bleeding and 17 (5.7%) inadequate procedures that were repeated. A total of 157 patients (52.8%) showed no increased AChE activity and the remaining patients (140-47.2.0%) presented patterns of increased AChE activity confirming the diagnosis of HD or neuronal intestinal dysplasia. Among the 140 cases suspected as having HD, in 131 children the diagnosis of HD was confirmed and they were operated on. The histological studies showed that 111 children presented the classic form of HD or a long spastic segment. Sixteen children presented total colonic aganglionosis and four children proved to have intestinal neuronal dysplasia, according to histological and radiological criteria. Nine (6.6%) newborns were identified as false-positives and no false-negative results were verified. The rectal suction biopsy combined with AChE staining is advantageous for the differentiation between normal bowel and intestinal dysganglionoses. The rectal suction method is simple and can easily be performed by experienced surgeons. The histological evaluation is very objective and can be performed by a non-pathologist.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the prevalence and clinical associated factors of alcohol use disorders (AUD) comorbidity in a large clinical sample of patients with obsessive-compulsive disorder (OCD). Methods: A cross-sectional study including 630 DSM-IV OCD patients from seven Brazilian university services, comparing patients with and without AUD comorbidity. The instruments of assessment used were a demographic and clinical questionnaire including evaluation of suicidal thoughts and acts and psychiatric treatment, the Structured Clinical Interview for DSM-IV Axis I disorders (SCID-I), the Yale-Brown Obsessive-Compulsive Scale, the Dimensional Yale-Brown Obsessive-Compulsive Scale, the Brown Assessment of Beliefs Scale, the Beck Depression and Anxiety Inventories and the Clinical Global Impression Scale. Current or past alcohol and other psychoactive substances use, abuse and dependence were assessed using the SCID-I (section E) and corroborated by medical and familial history questionnaires. Results: Forty-seven patients (7.5%) presented AUD comorbidity. Compared to OCD patients without this comorbidity they were more likely to be men, to have received previous psychiatric treatment, to present: lifetime suicidal thoughts and attempts and to have higher scores in the hoarding dimension. They also presented higher comorbidity with generalized anxiety and somatization disorders, and compulsive sexual behavior. Substance use was related to the appearance of the first O.C. symptoms and symptom amelioration. Conclusions: Although uncommon among OCD treatment seeking samples, AUD comorbidity has specific clinical features, such as increased risk for suicidality, which deserve special attention from mental health professionals. Future studies focused on the development of specific interventions for these patients are warranted. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the accuracy of preoperative magnetic resonance imaging (MRI) findings relative to surgical presence of deeply infiltrating endometriosis (DIE). Methods: This prospective study included 92 women with clinical suspicion of DIE. The MR images were compared with laparoscopy and pathology findings. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MRI for diagnosis of DIE were assessed. Results: DIE was confirmed at histopathology in 77 of the 92 patients (83.7%). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MRI to diagnose DIE at each of the specific sites evaluated were as follows: retrocervical space (89.4%, 92.3%, 96.7%, 77.4%, 90.2%); rectosigmoid (86.0%, 92.9%, 93.5%, 84.8%, 89.1%); bladder (23.1%, 100%,100%, 88.8%, 89.1%); ureters (50.0%, 100%, 95.5%, 95.7%); and vagina (72.7%, 100%, 100%, 96.4%, 96.7%). Conclusion: MRI demonstrates high accuracy in diagnosing DIE in the retrocervical region, rectosigmoid. bladder, ureters, and vagina. (C) 2009 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Lid. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The magnitude Of functional impairment that may indicate the threshold between MCI and incipient Alzheimer`s disease (AD) has not been clearly defined. The objective was to examine the pattern of functional impairment in the continuum MCI-AD. Eighty-nine older adults (32 cognitively unimpaired, 31 MCI, and 26 AD patients) were examined with the Brazilian version of the Direct Assessment of Functional Status (DAFS-BR) at a University-based memory clinic. MCI patients were sub-divided according to the progression to AD upon follow-up, and had baseline cognitive, functional and biological variables analyzed. MCI patients displayed mild deficits in functional abilities, with intermediate scores as compared to controls and AD. The DAFS-BR items that differentiated MCI from controls involved the ability to deal with finances and shopping skills. At baseline, scores obtained by MCI patients who converted to AD were not significantly different from scores of nonconverters. The magnitude of functional deficits was associated with AD-like pathological findings in the CSF. In conclusion, MCI patients present with early functional changes in complex, instrumental abilities that require the integrity of memory and executive functions. The objective measurement of the functional state may help identify older adults with increased risk of developing dementia in the MCI-AD continuum. (JINS, 2010, 16, 297-305.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and objective: Light`s criteria are frequently used to evaluate the exudative or transudative nature of pleural effusions. However, misclassification resulting from the use of Light`s criteria has been reported, especially in the setting of diuretic use in patients with heart failure (HF). The objective of this study was to evaluate the utility of B-type natriuretic peptide (BNP) measurements as a diagnostic tool for determining the cardiac aetiology of pleural effusions. Methods: Patients with pleural effusions attributable to HF (n = 34), hepatic hydrothorax (n = 10), pleural effusions due to cancer (n = 21) and pleural effusions due to tuberculosis (n = 12) were studied. Diagnostic thoracentesis was performed for all 77 patients. Receiver operating characteristic (ROC) curves were constructed to determine the diagnostic accuracy of plasma BNP and pleural fluid BNP for the prediction of HF. Results: The areas under the ROC curves were 0.987 (95% CI 0.93-0.998) for plasma BNP and 0.949 (95% CI 0.874-0.986) for pleural fluid BNP, for distinguishing between patients with pleural effusions caused by HF (n = 34) and those with pleural effusions attributable to other causes (n = 43). The cut-off concentrations with the highest diagnostic accuracy for the diagnosis of HF as the cause of pleural effusion were 132 pg/mL for plasma BNP (sensitivity 97.1%, specificity 97.4%) and 127 pg/mL for pleural fluid BNP (sensitivity 97.1%, specificity 87.8%). Conclusions: In patients with pleural effusions of suspected cardiac origin, measurements of BNP in plasma and pleural fluid may be useful for the diagnosis of HF as the underlying cause.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To compare videofluoroscopy swallowing study (VFSS) with the fiberoptic endoscopic evaluation of swallowing (FEES) in children and to determine the accuracy of FEES in the diagnosis of specific swallowing disorders. STUDY DESIGN: Cross-sectional study. SETTING: Hospital da Crianca Santo Antonio, affiliated with Santa Casa de Misericordia Hospital Complex, Porto Alegre, RS, Brazil. SUBJECTS AND METHODS: FEES findings were compared to those of VFSS in 30 children. Kappa coefficients for interobserver agreement were calculated. Thereafter, these coefficients were evaluated in terms of agreement between FEES and VFSS. In addition, the sensitivity, specificity, positive predictive value, and negative predictive value of FEES were calculated for four swallowing parameters (posterior spillover, pharyngeal residues, laryngeal penetration, and laryngotracheal aspiration). RESULTS: Interobserver agreement rates greater than 70 percent were obtained for all FEES parameters analyzed, except for pharyngeal residues with puree consistency (agreement = 66.7%, K = 0.296, P = 0.091). Laryngeal aspiration and penetration yielded the best level of agreement (100%, K = 1) for the laryngeal aspiration of puree residues. CONCLUSION: The diagnostic agreement between FEES (both observers) and VFSS was low. Regarding the analyzed parameters, laryngeal penetration and aspiration yielded the highest interobserver agreement in terms of FEES, and also showed the highest specificity and positive predictive value when compared to VFSS. (C) 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and objective: Tuberculosis (TB) and cancer are two of the main causes of pleural effusions which frequently share similar clinical features and pleural fluid profiles. This study aimed to identify diagnostic models based on clinical and laboratory variables to differentiate tuberculous from malignant pleural effusions. Methods: A retrospective study of 403 patients (200 with TB; 203 with cancer) was undertaken. Univariate analysis was used to select the clinical variables relevant to the models composition. Variables beta coefficients were used to define a numerical score which presented a practical use. The performances of the most efficient models were tested in a sample of pleural exudates (64 new cases). Results: Two models are proposed for the diagnosis of effusions associated with each disease. For TB: (i) adenosine deaminase (ADA), globulins and the absence of malignant cells in the pleural fluid; and (ii) ADA, globulins and fluid appearance. For cancer: (i) patient age, fluid appearance, macrophage percentage and presence of atypical cells in the pleural fluid; and (ii) as for (i) excluding atypical cells. Application of the models to the 64 pleural effusions showed accuracy higher than 85% for all models. Conclusions: The proposed models were effective in suggesting pleural tuberculosis or cancer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cutaneous tuberculosis has re-emerged in the last 15 years together with the higher incidence of pulmonary tuberculosis and multidrug resistance. The choice for a single diagnostic tool among the many available today is a challenge. Our objective was to compare polymerase chain reaction (PCR) with other exams in the diagnosis of cutaneous tuberculosis and atypical mycobacteria skin infection. PCR and a set of five different exams were performed in 32 patients (34 samples of paraffin-embedded tissue) evaluated for 3 years in a university hospital, considering the response to mycobacterial infection treatment as a positive case. PCR was the most sensitive (88%) and specific (83%) exam. Culture, immunohistochemistry and acid-fast bacilli were not in agreement with clinical response to treatment. Although PCR is a useful tool, careful clinical exam is still the gold standard for the evaluation and treatment of cutaneous tuberculosis and mycobacteria skin infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of the study was to evaluate clinical and laboratorial features of 1234 patients with different etiologies of hyper-prolactinemia, as well as the response of 388 patients with prolactinomas to dopamine agonists. Design, setting, and patients: A total of 1234 hyperprolactinemic patients from 10 Brazilian endocrine centers were enrolled in this retrospective study. Main outcome measure: PRL measurement, thyroid function tests, and screening for macroprolactin were conducted. Results: Patients were subdivided as follows: 56.2% had prolactinomas, 14.5% drug-induced hyperprolactinemia, 9.3% macroprolactinemia, 6.6% non-functioning pituitary adenomas, 6.3% primary hypothyroidism, 3.6% idiopathic hyperprolactinemia, and 3.2% acromegaly. Clinical manifestations were similar irrespective of the etiology of the hyperprolactinemia. The highest PRL levels were observed in patients with prolactinomas but there was a great overlap in PRL values between all groups. However, PRL>500 ng/ml allowed a clear distinction between prolactinomas and the other etiologies. Cabergoline (CAB) was more effective than bromocriptine (BCR) in normalizing PRL levels (81.9% vs 67.1%, p<0.0001) and in inducing significant tumor shrinkage and complete disappearance of tumor mass. Drug resistance was observed in 10% of patients treated with CAB and in 18.4% of those that used BCR (p=0.0006). Side-effects and intolerance were also more common in BCR-treated patients. Conclusion: Prolactinomas, drug-induced hyperprolactinemia, and macroprolactinemia were the 3 most common causes of hyperprolactinemia. Although PRL levels could not reliably define the etiology of hyperprolactinemia, PRL values >500 ng/ml were exclusively seen in patients with prolactinomas. CAB was significantly more effective than BCR in terms of prolactin normalization, tumor shrinkage, and tolerability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To describe the natural history of fetuses presenting with pleural effusion. Methods Between January 2005 and December 2009 all fetuses diagnosed with pleural effusion were followed up. Fetuses were divided into three groups: I, isolated pleural effusion; II, associated structural anomalies but normal karyotype; and III, chromosomal anomalies. Univariate and multivariate analyses were performed to determine the association between prenatal ultrasound findings and perinatal death. Results Fifty-six fetuses were included in the study. Associated structural or chromosomal anomalies occurred in 75.0% (42/56) of cases. Bilateral pleural effusion and fetal hydrops were associated with each other (p < 0.01) and with perinatal death (p < 0.05). Multivariate analysis indicated that only the presence of associated abnormalities was a statistical determinant of perinatal death (OR, 3.56; 95% CI, 1.48-5.64; p < 0.01). Conclusion Fetal pleural effusion is often associated with other abnormalities, and this association has poor perinatal outcome. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chagas` disease caused by Trypanosoma cruzi is endemic in Latin America. T. cruzi presents heterogeneous populations and comprises two main genetic lineages, named T. cruzi I and T. cruzi II. Diagnosis in the chronic phase is based on conventional serological tests, including indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (ELISA), and diagnosis in the acute phase based on parasitological methods, including hemoculture. The objective of this study was to evaluate the diagnostic procedures of Chagas` disease in adult patients in the chronic phase by using a PCR assay and conventional serological tests, including TESA-blot as the gold standard. Samples were obtained from 240 clinical chronic chagasic patients. The sensitivities, compared to that of TESA-blot, were 70% for PCR using the kinetoplast region, 75% for PCR using the nuclear repetitive region, 99% for IIF, and 95% for ELISA. According to the serological tests results, we recommend that researchers assess the reliability and sensitivity of the commercial kit Chagatest ELISA recombinant, version 3.0 (Chagatest Rec v3.0; Wiener Lab, Rosario, Argentina), due to the lack of sensitivity. Based on our analysis, we concluded that PCR cannot be validated as a conventional diagnostic technique for Chagas` disease. These data have been corroborated by low levels of concordance with serology test results. It is recommended that PCR be used only for alternative diagnostic support. Using the nuclear repetitive region of T. cruzi, PCR could also be applicable for monitoring patients receiving etiologic treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SETTING: Itaborai Municipality in Rio de Janeiro, Brazil. OBJECTIVE: To evaluate access to tuberculosis (TB) diagnosis for users of the Family Health Program (FHP) and Reference Ambulatory Units (RAUs). DESIGN : A cross-sectional study was conducted in Itaborai City, Rio de Janeiro, Brazil. Between July and October 2007, a sample of 100 TB patients registered consecutively with the TB Control Program was interviewed using the primary care assessment tool. The two highest scores, describing `almost always` and `always`, or `good` and `very good`, were used as a cut-off point to define high quality access to diagnosis. RESULTS: FHP patients were older and had less education than RAU interviewees. Sex and overcrowding did not differ in the two groups. Patient groups did not differ with regard to the number of times care was sought at a unit, transport problems, cost of attending units and availability of consultation within 24 h. Adequate access to diagnosis was identified by 62% of the FHP patients and 53% of the RAU patients (P = 0.01). CONCLUSION: In Itaborai, Rio de Janeiro, TB patients believe that the FHP units provide greater access to TB diagnosis than RAUs. These findings will be used by the Department of Health to improve access to diagnosis in Itaborai.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To investigate the accuracy of the Brazilian version of the Addenbrooke Cognitive Examination-revised (ACE-R) in the diagnosis of mild Alzheimer disease (AD). Background: The ACE-R is an accurate and brief cognitive battery for the detection of mild dementia, especially for the discrimination between AD and frontotemporal dementia. Methods: The battery was administered to 31 patients with mild AD and 62 age-matched and education-matched cognitively healthy controls. Both groups were selected using the Dementia Rating Scale and were submitted to the ACE-R. Depression was ruled out in both groups by the Cornell Scale for Depression in Dementia. The performance of patients and controls in the ACE-R was compared and receiver operator characteristic curve analysis was undertaken to ascertain the accuracy of the instrument for the diagnosis of mild AD. Results: The mean scores at the ACE-R were 63.10 +/- 10.22 points for patients with AD and 83.63 +/- 7.90 points for controls. The cut-off score < 78 yielded high diagnostic accuracy (receiver operator characteristic area under the curve = 0.947), with 100% sensitivity, 82.26% specificity, 73.8% positive predictive value, and 100% negative predictive value. Conclusions: The Brazilian version of the ACE-R displayed high diagnostic accuracy for the identification of mild AD in the studied sample.