33 resultados para Non-destructive methods

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, an algorithm to compute the envelope of non-destructive testing (NDT) signals is proposed. This method allows increasing the speed and reducing the memory in extensive data processing. Also, this procedure presents advantage of preserving the data information for physical modeling applications of time-dependent measurements. The algorithm is conceived to be applied for analyze data from non-destructive testing. The comparison between different envelope methods and the proposed method, applied to Magnetic Bark Signal (MBN), is studied. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background/purpose: Vitamins C and its derivatives, mainly due to their antioxidant properties, are being used in cosmetic products to protect and to reduce the signs of ageing. However, there are no studies comparing the effects of vitamin C [ascorbic acid (AA)] and its derivatives, magnesium ascorbyl phosphate (MAP) and ascorbyl tetra-isopalmitate (ATIP), when vehiculated in topical formulations, mainly using objective measurements, which are an important tool in clinical efficacy studies. Thus, the objective of this study was to determine the in vitro antioxidant activity of AA and its derivatives, MAP and ATIP, as well as their in vivo efficacy on human skin, when vehiculated in topical formulations. Methods: The study of antioxidant activity in vitro was performed with an aqueous and a lipid system. The in vivo methodology consisted of the application of these formulations on human volunteers` forearm skin and the analysis of the skin conditions after 4-week period daily applications in terms of transepidermal water loss (TEWL), stratum corneum moisture content and viscoelasticity using a Tewameter (R), Corneometer (R) and Cutometer (R), respectively. Results: In vitro experiments demonstrated that in an aqueous system, AA had the best antioxidant potential, and MAP was more effective than ATIP, whereas in the lipid system ATIP was more effective than MAP. In in vivo studies, all formulations enhanced stratum corneum moisture content after a 4-week period daily applications when compared with baseline values; however, only the formulation containing AA caused alterations in TEWL values. The formulations containing MAP caused alterations in the viscoelastic-to-elastic ratio, which suggested its action in the deeper layers of the skin. Conclusion: AA and its derivates presented an in vitro antioxidant activity but AA had the best antioxidant effect. In in vivo efficacy studies, only the formulation containing AA caused alterations in TEWL values and the formulation containing MAP caused alterations in the viscoelastic-to-elastic ratio. This way, vitamin C derivatives did not present the same effects of AA on human skin; however, MAP showed other significant effect-improving skin hydration, which is very important for the normal cutaneous metabolism and also to prevent skin alterations and early ageing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Simple, rapid and stable sperm evaluation methods which have been optimized for common marmoset (Callithrix jacchus) are critical for studies involving collection and evaluation of sperm in the field. This is particularly important for new species groups such as Callitrichidae where the sperm have been little studied. Of this family, C jacchus is the best known, and has been chosen as a model species for other members of the genus Callithrix. The fundamental evaluation parameters for sperm of any species are viability and acrosomal status. Semen samples were collected by penile vibratory stimulation. To evaluate sperm plasma membrane integrity, Eosin-Nigrosin was tested here for the common marmoset sperm to be used under field conditions. Further, a non-fluorescent stain for acrosome, the ""Simple"" stain, developed for domestic and wild cats, was tested on common marmoset sperm. This was compared with a fluorescent staining, Fluorescein isothiocyanate-Pisum sativum agglutinin (FITC-PSA), routinely used and validated for common marmoset at the German Primate Centre to evaluate acrosomal integrity. Results obtained with the ""Simple"" stain showed a marked differentiation between sperm with intact and non-intact acrosome both with and without ionophore treatment and closely correlated with results obtained with FITC-PSA. Temperature had no effect on the results with the ""Simple"" stain and the complete processing is simple enough to be carried out under field conditions. These findings indicated that the ""Simple"" stain and Eosin-Nigrosin provide rapid and accurate results for C. jacchus sperm and that those methods can be reliably used as field tools for sperm evaluation for this species. (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Carrying out information about the microstructure and stress behaviour of ferromagnetic steels, magnetic Barkhausen noise (MBN) has been used as a basis for effective non-destructive testing methods, opening new areas in industrial applications. One of the factors that determines the quality and reliability of the MBN analysis is the way information is extracted from the signal. Commonly, simple scalar parameters are used to characterize the information content, such as amplitude maxima and signal root mean square. This paper presents a new approach based on the time-frequency analysis. The experimental test case relates the use of MBN signals to characterize hardness gradients in a AISI4140 steel. To that purpose different time-frequency (TFR) and time-scale (TSR) representations such as the spectrogram, the Wigner-Ville distribution, the Capongram, the ARgram obtained from an AutoRegressive model, the scalogram, and the Mellingram obtained from a Mellin transform are assessed. It is shown that, due to nonstationary characteristics of the MBN, TFRs can provide a rich and new panorama of these signals. Extraction techniques of some time-frequency parameters are used to allow a diagnostic process. Comparison with results obtained by the classical method highlights the improvement on the diagnosis provided by the method proposed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The citrus greening (or huanglongbing) disease has caused serious problems in citrus crops around the world. An early diagnostic method to detect this malady is needed due to the rapid dissemination of Candidatus Liberibacter asiaticus (CLas) in the field. This analytical study investigated the fluorescence responses of leaves from healthy citrus plants and those inoculated with CLas by images from a stereomicroscope and also evaluated their potential for the early diagnosis of the infection caused by this bacterium. The plants were measured monthly, and the evolution of the bacteria on inoculated plants was monitored by real-time quantitative polymerase chain reaction (RT-qPCR) amplification of CLas sequences. A statistical method was used to analyse the data. The selection of variables from histograms of colours (colourgrams) of the images was optimized using a paired Student's t-test. The intensity of counts for green colours from images of fluorescence had clearly minor variations for healthy plants than diseased ones. The darker green colours were the indicators of healthy plants and the light colours for the diseased. The method of fluorescence images is novel for fingerprinting healthy and diseased plants and provides an alternative to the current method represented by PCR and visual inspection. A new, non-subjective pattern of analysis and a non-destructive method has been introduced that can minimize the time and costs of analyses.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work, a fast, non destructive voltammetric method for cocaine detection in acetonitrile medium using a platinum disk electrode chemically modified with cobalt-hexacyanoferrate (CoHCFe) film is described. The deposition of CoHCFe film at platinum disk (working electrode) was carried out in aqueous solution containing NaClO(4) at 0.1 mol L(-1) as supporting electrolite. Stability studies of the film and subsequent voltammetric analysis of cocaine were made in acetonitrile medium with NaClO4 at 0.1 mol L(-1) as supporting electrolite. A reversible interaction between cocaine and CoHCFe at the film produces a proportional decrease of original peak current, due to the formation of a complex between cocaine and cobalt ions, with subsequent partial passivation of the film surface, being the intensity of current decrease used as analytical signal for cocaine. A linear dependence of cocaine detection was carried out in the range from 2.4 x 10 x 4 to 1.5 x 10(-3) mol L(-1), with a linear correlation coefficient of 0.994 and a detection limit of 1.4 x 10 x 4 mol L(-1). The analysis of confiscated samples by the proposed method indicated cocaine levels from 37% to 95% (m/m) and these results were validated by comparison to HPLC technique, being obtained good correlation between both methods. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: The aim of this study was to evaluate root coverage of gingival recessions and to compare graft vascularization in smokers and non-smokers. Methods: Thirty subjects, 15 smokers and 15 non-smokers, were selected. Each subject had one Miller Class I or II recession in a non-molar tooth. Clinical measurements of probing depth (PD), relative clinical attachment level (CAL), gingival recession (GR), and width of keratinized tissue (KT) were determined at baseline and 3 and 6 months after surgery. The recessions were treated surgically with a coronally positioned flap associated with a subepithelial connective tissue graft. A small portion of this graft was prepared for immunohistochemistry. Blood vessels were identified and counted by expression of factor VIII-related antigen-stained endothelial cells. Results: Intragroup analysis showed that after 6 months there a was gain in CAL, a decrease in GR, and an increase in KT for both groups (P<0.05), whereas changes in PD were not statistically significant. Smokers had less root coverage than non-smokers (58.02% +/- 19.75% versus 83.35% +/- 18.53%; P<0.05). Furthermore, the smokers had more GR (1.48 +/- 0.79 mm versus 0.52 +/- 0.60 mm) than the nonsmokers (P<0.05). Histomorphometry of the donor tissue revealed a blood vessel density of 49.01 +/- 11.91 vessels/200x field for non-smokers and 36.53 +/- 10.23 vessels/200x field for smokers (P<0.05). Conclusion: Root coverage with subepithelial connective tissue graft was negatively affected by smoking, which limited and jeopardized treatment results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The thermal decomposition of salbutamol (beta(2) - selective adrenoreceptor) was studied using differential scanning calorimetry (DSC) and thermogravimetry/derivative thermogravimetry (TG/DTG). It was observed that the commercial sample showed a different thermal profile than the standard sample caused by the presence of excipients. These compounds increase the thermal stability of the drug. Moreover, higher activation energy was calculated for the pharmaceutical sample, which was estimated by isothermal and non-isothermal methods for the first stage of the thermal decomposition process. For isothermal experiments the average values were E(act) = 130 kJ mol(-1) (for standard sample) and E(act) = 252 kJ mol(-1) (for pharmaceutical sample) in a dynamic nitrogen atmosphere (50 mL min(-1)). For non-isothermal method, activation energy was obtained from the plot of log heating rates vs. 1/T in dynamic air atmosphere (50 mL min(-1)). The calculated values were E(act) = 134 kJ mol(-1) (for standard sample) and E(act) (=) 139 kJ mol(-1) (for pharmaceutical sample).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUÇÃO: O arco e flecha é um esporte estático que requer força e resistência da parte superior do corpo, sendo que a habilidade do arqueiro é definida pela capacidade de atirar a flecha no alvo em um intervalo de tempo com precisão. A contração muscular gerada durante a execução do gesto esportivo propicia o aumento da temperatura corporal, da oxidação de glicose e da sudorese, podendo esta ser potencializada pelas condições climáticas às quais o atleta é exposto. Todos estes fatores alteram a percepção de esforço e a própria geração de força, impondo um estresse negativo à performance. OBJETIVOS: Avaliar e relacionar o estado de hidratação de atletas de arco e flecha com alterações fisiológicas e de força intervenientes no rendimento competitivo. MÉTODOS: Participaram 11 arqueiros em duas competições distintas (indoor e outdoor). Foram mensurados parâmetros relacionados ao estado de hidratação, glicemia, percepção de esforço subjetivo e alteração na força de preensão palmar. RESULTADOS: Os atletas analisados apresentaram alterações significativas nos parâmetros relacionados ao estado hídrico em diferentes dias, provavelmente relacionadas às condições climáticas adversas na competição outdoor (34ºC e 60% URA) em relação à competição indoor (22ºC e 90% URA). O mesmo não foi observado para a glicemia. CONCLUSÃO: Este trabalho é o primeiro a comprovar a relação direta entre fatores climáticos e de rendimento em arqueiros de alto nível durante evento competitivo, assim como a evidenciar quais métodos não invasivos seriam os mais indicados para a avaliação do impacto destas alterações.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Estimar as prevalências de comportamentos prejudiciais à saúde e de outros fatores de risco cardiovascular entre idosos com hipertensão auto-referida e comparando-as com de não-hipertensos. MÉTODOS: Foram utilizados dados do sistema de Vigilância de Fatores de Risco e Proteção para Doenças Crônicas por Inquérito Telefônico (VIGITEL), referentes aos 9.038 idosos residentes em domicílios com pelo menos uma linha telefônica fixa nas 26 capitais brasileiras e no Distrito Federal em 2006. RESULTADOS: A prevalência de hipertensão auto-referida foi de 55% (IC 95%: 53;57). A maioria dos hipertensos apresentava concomitância de três ou mais fatores de risco (69%; IC 95%: 67;71). Foram observadas altas prevalências de atividades físicas insuficientes no lazer (88%; IC 95%: 86;89) e do consumo de frutas e hortaliças inferior a cinco porções diárias (90%; IC 95%: 88;90) entre hipertensos, seguidas pela adição de sal aos alimentos (60%; IC 95%: 57;63), consumo habitual de carnes gordurosas (23%; IC 95%: 21;25), tabagismo (9%; IC 95%: 7;10) e consumo abusivo de álcool (3%; IC 95%: 2;4). Essas prevalências foram semelhantes às observadas entre não hipertensos (p >0,05), exceto tabagismo. A prevalência do tabagismo foi menor entre hipertensos (razão de prevalência ajustada [RPA] = 0,75; IC 95%: 0,64;0,89) e as prevalências de sobrepeso (RPA= 1,37; IC 95%: 1,25;1,49), dislipidemia (RPA 1,36; IC 95%: 1,26;1,36) e diabetes (RPA= 1,37; IC 95%: 1,27;1,37) foram mais altas. CONCLUSÕES: Os resultados sugerem que, exceto tabagismo, os comportamentos prejudiciais à saúde entre idosos persistem após o diagnóstico da hipertensão arterial.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

According to some estimates, world's population growth is expected about 50% over the next 50 years. Thus, one of the greatest challenges faced by Engineering is to find effective options to food storage and conservation. Some researchers have investigated how to design durable buildings for storing and conserving food. Nowadays, developing concrete with mechanical resistance for room temperatures is a parameter that can be achieved easily. On the other hand, associating it to low temperature of approximately 35 °C negative requires less empiricism, being necessary a suitable dosage method and a careful selection of the material constituents. This ongoing study involves these parameters. The presented concrete was analyzed through non-destructive tests that examines the material properties periodically and verifies its physical integrity. Concrete with and without incorporated air were studied. The results demonstrated that both are resistant to freezing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ultraprecision diamond turning was used to evaluate the surface integrity of a carbon nanotube (CNT) composite as a function of the cutting conditions and the percentage of CNT in the epoxy matrix. The effects of cutting conditions on the chip morphology and surface roughness were analysed. The results showed that an increase in the percentage of CNT may influence the mechanism of material removal and consequently improve the quality of the machined surface. When smaller quantities of CNT (0.02 and 0.07 wt %) are present in the matrix, microcracks form within the cutting grooves (perpendicular to the cutting direction). This indicates that the amount of CNT on the epoxy matrix may have a direct influence on the mechanical properties of these materials. Chips removed from the CNT composite samples were analysed by scanning electron microscopy in order to correlate the material removal mechanism and the surface generation process. The area average surface roughness Sa was influenced by the material removal mechanism (Sa ranging from 0.28 to 1.1 mu m).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

P>Soil bulk density values are needed to convert organic carbon content to mass of organic carbon per unit area. However, field sampling and measurement of soil bulk density are labour-intensive, costly and tedious. Near-infrared reflectance spectroscopy (NIRS) is a physically non-destructive, rapid, reproducible and low-cost method that characterizes materials according to their reflectance in the near-infrared spectral region. The aim of this paper was to investigate the ability of NIRS to predict soil bulk density and to compare its performance with published pedotransfer functions. The study was carried out on a dataset of 1184 soil samples originating from a reforestation area in the Brazilian Amazon basin, and conventional soil bulk density values were obtained with metallic ""core cylinders"". The results indicate that the modified partial least squares regression used on spectral data is an alternative method for soil bulk density predictions to the published pedotransfer functions tested in this study. The NIRS method presented the closest-to-zero accuracy error (-0.002 g cm-3) and the lowest prediction error (0.13 g cm-3) and the coefficient of variation of the validation sets ranged from 8.1 to 8.9% of the mean reference values. Nevertheless, further research is required to assess the limits and specificities of the NIRS method, but it may have advantages for soil bulk density predictions, especially in environments such as the Amazon forest.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A method for simultaneous determination of Cr, Fe, Co, Ni, Cu, Zn, As e Pb in liquid chemical waste using Energy Dispersive X-Ray Fluorescence (EDXRF) technique was evaluated. A small sample amount (200 mu L) was dried on a 6.35 mu m thickness Mylar film at 60 degrees C and the analyses were carried out using an EDXRF spectrometer operated with an X-ray Mo tube (Zr filter) at 30 kV/20 mA. The acquisition time was 300 s and the Ga element was utilized as internal standard at 25 mg/L for quantitative analysis. The method trueness was assessed by spiking and the detection limit for those elements ranged from 0.39 to 1.7 mg/L. This method is notable because it assists the choice of the more appropriated waste treatment procedure, in which inter elemental interference is a matter of importance. In addition, this inexpensive method allows a non-destructive determination of the elements from (19)K to (92)U simultaneously.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The magnetic Barkhausen noise (MBN) is a phenomenon sensitive to several kinds of magnetic material microstructure changes, as well as to variations in material plastic deformation and stress. This fact stimulates the development of MBN-based non-destructive testing (NDT) techniques for analyzing magnetic materials, being the proposition of such a method, the main objective of the present study. The behavior of the MBN signal envelope, under simultaneous variations of carbon content and plastic deformation, is explained by the domain wall dynamics. Additionally, a non-destructive parameter for the characterization of each of these factors is proposed and validated through the experimental results. (C) 2010 Elsevier B.V. All rights reserved.