7 resultados para Mitek mini anchor
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Background: the Mini Nutritional Assessment (MNA) is a multidimensional method of nutritional evaluation that allows the diagnosis of malnutrition and risk of malnutrition in elderly people, it is important to mention that this method has not been well studied in Brazil. Objective: to verify the use of the MNA in elderly people that has been living in long term institutions for elderly people. Design: transversal study. Participants: 89 people (>= 60 years), being 64.0% men. The average of age for both genders was 73.7 +/- 9.1 years old, being 72.8 +/- 8.9 years old for men, and 75.3 +/- 9.3 years old for women. Setting: long-term institutions for elderly people located in the Southeast of Brazil. Methods: it was calculated the sensibility, specificity, and positive and negative predictive values. It was data to set up a ROC curve to verify the accuracy of the MNA. The variable used as a ""standard"" for the nutritional diagnosis of the elderly people was the corrected arm muscle area because it is able to provide information or an estimative of the muscle reserve of a person being considered a good indicator of malnutrition in elderly people. Results: the sensibility was 84.0%, the specificity was 36.0%, the positive predictive value was 77.0%, and the negative predictive value was 47.0%; the area of the ROC curve was 0.71 (71.0%). Conclusion: the MNA method has showed accuracy, and sensibility when dealing with the diagnosis of malnutrition and risk of malnutrition in institutionalized elderly groups of the Southeastern region of Brazil, however, it presented a low specificity.
Resumo:
The objective of this study was to evaluate the stress distribution in the resin in contact with the spirals of cylindrical and conical mini-implants, when submitted to lateral load and insertion torsion. A photoelastic model was fabricated using transparent gelatin to simulate the alveolar bone. The model was observed with a plane polariscope and photographically recorded before and after activation of the two screws with a lateral force and torsion. The lateral force application caused bending moments on both mini-implants, with the uprising of fringes or isochromatics, characteristics of stresses, along the threads of the mini-implants and in the apex. When the torsion was exerted in the mini-implants, a great concentration of stress upraised close to the apex. The conclusion was that, comparing conical with cylindrical mini-implants under lateral load, the stresses were similar on the traction sides. The differences appear (1) on the apex, where the cylindrical mini-implant showed a greater concentration of stress, and (2) along the spirals, in the compression side, where the conical mini-implant showed a greater concentration of stress. The greater part of the stress produced by both mini-implants, after torsion load in insertion, were concentrated on the apex. With the cylindrical mini-implant, the greater concentration of tension was close to the apex, while with the conical one, the stresses were distributed along a greater amount of apical threads.
Resumo:
The purpose of this study was to analyze and compare scanning electron microscopy (SEM) observations of ball attachments that had been worn by patients during three periods of clinical use. One hundred forty-four specimens of ball anchor attachments (gold alloy matrix and titanium patrix) were studied by SEM after periods of approximately 1, 3.5, and 8 years of clinical use. Twenty new attachment components were examined as controls. SEM images revealed signs of mechanical wear for the ball attachments studied. The surfaces of the titanium patrix were associated primarily with roughening after short-term use, whereas surfaces of the gold alloy matrix showed wear, roughening, and loss of microscopic material in the form of flakes. Severe mechanical wear on both surfaces was noted after longer periods of use. The mechanical changes were not correlated with patient-mediated observations regarding the time-dependent retentive efficacy of the attachments. One year of clinical wear appeared to have limited effect on the ball attachment tested. Conversely, longer periods of use led to marked modifications in shape of the matrix and patrix components. Int J Prosthodont 2011;24:270-272.
Resumo:
Distalization of maxillary molars is indicated for correction of Class II dental malocclusion and for space gain in cases of space deficiency. The ideal treatment with an intraoral fixed appliance for molar distalization should fulfill the following requirements: patient compliance; acceptable esthetics; comfort; minimum anterior anchor loss (as evidenced by inclination of incisors); bodily movement of the molars to avoid undesirable effects and unstable outcomes; and minimum time required during sessions for placement and activations. The purpose of this paper was to present an alternative treatment for space recovery in the area of the maxillary right second premolar when there has been significant mesial movement of the permanent maxillary right first molar. We used a modified appliance that allows unilateral molar distalization in cases of unilateral tooth/arch size discrepancy using the opposite side as anchor, thus reducing the mesialization of the anterior teeth. (Pediatr Dent 2008;30:334-41) Received August 17, 2006 / Last Revision October 17, 2007 / Revision Accepted October 17, 2007
Resumo:
Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.
Resumo:
An increase in cutaneous and visceral leishmaniasis cases has been reported in recent years in the state of Mato Grosso do Sul, Brazil, and little is known to date about their etiological agents. An investigation into natural Leishmania infection of sand flies captured in this state between December 2003 and August 2004 was carried out. Mini-exon sequences were used as targets to identify Leishmania, and an RFLP technique was employed for those identified as belonging to the Viannia subgenus. Calculation of the minimal infection rate (MR) revealed that 1.6% of sand flies captured in the forest, peridomicile and intradomicile were positive. Six species were found to be infected by Leishmania (V.) braziliensis. Interestingly, two of the six species. Lutzomyia longipalpis and Nyssomyia whitmani, were captured in anthropic environments. The findings of this study constitute a useful tool for planning control measures against this disease in the State of Mato Grosso do Sul. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Purpose: Peak expiratory flow (PEF) was measured in healthy children aged five to ten years in order to provide baseline values and to determine correlations between PEF and factors such as gender, age and type of school. Methods: After the Ethical Committee of Research in Human of the School of Medicine of ABC - FMABC approval, PEF and height were measured in 1942 children between five and ten years old from nine public schools and nine private schools throughout Sao Bernardo do Campo City. PEF was measured using the Mini-Wright Peak Flow Meter (Clement Clarke International Ltd.) and. height was measured using a Sanny professional stadiometer. Results: Significant differences were found in values for PEF: higher values were seen in older students in comparison with younger students, in males in comparison with females and in students from private schools in comparison with public schools, with average values ranging from 206 L/min to 248 L/min,. Linear correlations were seen for PEF values with both height and age (Spearman Coefficient). Conclusions: Differences were seen for PEF between genders and between types of school, and a linear correlation was seen for PEF with both age and height in healthy children from five to ten years old.